2025-7-11 18.97.9.175
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JB/T 8734.4-2016
JB/T 8734.4-2016   Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V —Part 4 : Insulated wires for internal wiring of equipment (English Version)
Standard No.: JB/T 8734.4-2016 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 5000 words Price(USD):120.0 remind me the price change

Email:

Implemented on:2016-9-1 Delivery: via email in 1 business day
,,
Standard No.: JB/T 8734.4-2016
English Name: Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V —Part 4 : Insulated wires for internal wiring of equipment
Chinese Name: 额定电压450/750V及以下聚氯乙烯绝缘电缆电线和软线 第4部分:安装用电线
Professional Classification: JB    Professional Standard - Machinery
Issued by: Ministry of Industry and Information Technology
Issued on: 2016-04-05
Implemented on: 2016-9-1
Status: valid
Superseding:JB/T 8734.4-2012 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V —Part 4 : Insulated wires for internal wiring of equipment
Language: English
File Format: PDF
Word Count: 5000 words
Price(USD): 120.0
Delivery: via email in 1 business day
1 Scope This part of JB/T 8734 specifies the service characteristics, type, specification, technical requirements and inspection of insulated wires for internal wiring of equipment. This part is applicable to copper-cored polyvinyl chloride (PVC) insulated wires for internal wiring of electrical appliances, instruments, electronic equipment and automation devices of AC rated voltage U0/U up to and including 300/300V. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 11: Methods for General Application - Measurement of Thickness and Overall Dimensions - Tests for Determining the Mechanical Properties GB/T 2951.12-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 12: Methods for General Application - Thermal Ageing Methods GB/T 2951.13-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 13: Methods for General Application - Measurement for Determining the Density - Water Absorption Tests - Shrinkage Test GB/T 2951.14-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 14: Methods for General Application - Test at Low Temperature GB/T 2951.31-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 31: Methods Specific to PVC Compounds - Pressure Test at High Temperature - Test for Resistance to Cracking GB/T 2951.32-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 32: Methods Specific to PVC Compounds - Loss of Mass Test - Thermal Stability Test GB/T 5023.2-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V - Part 2: Test Methods GB/T 18380.12-2008 Test on Electric and Optical Fibre Cables under Fire Conditions - Part 12: Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for 1KW Pre-mixed Flame GB/T 18380.22-2008 Tests on Electric and Optical Fibre Cables under Fire Conditions - Part 22: Test for Vertical Flame Propagation for a Single Small Insulated Wire or Cable - Procedure for Diffusion Flame JB/T 8734.1-2016 Polyvinyl Chloride Insulated Cables and Wires and Cords of Rated Voltages Up to and Including 450/750V - Part 1: General Requirements 3 Service Characteristics 3.1 The rated voltage U0/U of wire is 300/300V. 3.2 The long-term allowable operating temperature of AV-90 and AVR-90 wires shall not exceed 90℃ and that for other types shall not exceed 70℃.
Foreword i 1 Scope 2 Normative References 3 Service Characteristics 4 Type 5 Specification 6 Technical Requirements 6.1 General Provisions 6.2 Conductor 6.3 Insulation 6.4 Insulated Wire Core Cabling 6.5 Sheath 6.6 Outside Diameter or Boundary Dimension 7 Inspection Table 1 Types and Names Table 2 Specification Table 3 AV and AV-90 300/300V Copper-cored PVC Insulated Wires for Internal Wiring of Equipment Table 4 AVR and AVR-90 300/300V Copper-cored PVC Insulated Cords for Internal Wiring of Equipment Table 5 AVRB 300/300V Flat Copper-cored PVC Insulated Cords for Internal Wiring of Equipment Table 6 AVRS 300/300V Twisted Copper-cored PVC Insulated Cords for Internal Wiring of Equipment Table 7 AVVR 300/300V Copper-cored PVC Insulated and Sheathed PVC cords for Internal Wiring of Equipment Table 8 Inspection
JB/T 8734.4-2016 is referred in:
*JB/T 8734.1-2016 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V — Part 1:General requirements
Code of China
Standard
JB/T 8734.4-2016  Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V —Part 4 : Insulated wires for internal wiring of equipment (English Version)
Standard No.JB/T 8734.4-2016
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)120.0
Implemented on2016-9-1
Deliveryvia email in 1 business day
Detail of JB/T 8734.4-2016
Standard No.
JB/T 8734.4-2016
English Name
Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V —Part 4 : Insulated wires for internal wiring of equipment
Chinese Name
额定电压450/750V及以下聚氯乙烯绝缘电缆电线和软线 第4部分:安装用电线
Chinese Classification
Professional Classification
JB
ICS Classification
Issued by
Ministry of Industry and Information Technology
Issued on
2016-04-05
Implemented on
2016-9-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
JB/T 8734.4-2012 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V —Part 4 : Insulated wires for internal wiring of equipment
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
120.0
Keywords
JB/T 8734.4-2016, JB 8734.4-2016, JBT 8734.4-2016, JB/T8734.4-2016, JB/T 8734.4, JB/T8734.4, JB8734.4-2016, JB 8734.4, JB8734.4, JBT8734.4-2016, JBT 8734.4, JBT8734.4
Introduction of JB/T 8734.4-2016
1 Scope This part of JB/T 8734 specifies the service characteristics, type, specification, technical requirements and inspection of insulated wires for internal wiring of equipment. This part is applicable to copper-cored polyvinyl chloride (PVC) insulated wires for internal wiring of electrical appliances, instruments, electronic equipment and automation devices of AC rated voltage U0/U up to and including 300/300V. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 11: Methods for General Application - Measurement of Thickness and Overall Dimensions - Tests for Determining the Mechanical Properties GB/T 2951.12-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 12: Methods for General Application - Thermal Ageing Methods GB/T 2951.13-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 13: Methods for General Application - Measurement for Determining the Density - Water Absorption Tests - Shrinkage Test GB/T 2951.14-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 14: Methods for General Application - Test at Low Temperature GB/T 2951.31-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 31: Methods Specific to PVC Compounds - Pressure Test at High Temperature - Test for Resistance to Cracking GB/T 2951.32-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 32: Methods Specific to PVC Compounds - Loss of Mass Test - Thermal Stability Test GB/T 5023.2-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages Up to and Including 450/750V - Part 2: Test Methods GB/T 18380.12-2008 Test on Electric and Optical Fibre Cables under Fire Conditions - Part 12: Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for 1KW Pre-mixed Flame GB/T 18380.22-2008 Tests on Electric and Optical Fibre Cables under Fire Conditions - Part 22: Test for Vertical Flame Propagation for a Single Small Insulated Wire or Cable - Procedure for Diffusion Flame JB/T 8734.1-2016 Polyvinyl Chloride Insulated Cables and Wires and Cords of Rated Voltages Up to and Including 450/750V - Part 1: General Requirements 3 Service Characteristics 3.1 The rated voltage U0/U of wire is 300/300V. 3.2 The long-term allowable operating temperature of AV-90 and AVR-90 wires shall not exceed 90℃ and that for other types shall not exceed 70℃.
Contents of JB/T 8734.4-2016
Foreword i 1 Scope 2 Normative References 3 Service Characteristics 4 Type 5 Specification 6 Technical Requirements 6.1 General Provisions 6.2 Conductor 6.3 Insulation 6.4 Insulated Wire Core Cabling 6.5 Sheath 6.6 Outside Diameter or Boundary Dimension 7 Inspection Table 1 Types and Names Table 2 Specification Table 3 AV and AV-90 300/300V Copper-cored PVC Insulated Wires for Internal Wiring of Equipment Table 4 AVR and AVR-90 300/300V Copper-cored PVC Insulated Cords for Internal Wiring of Equipment Table 5 AVRB 300/300V Flat Copper-cored PVC Insulated Cords for Internal Wiring of Equipment Table 6 AVRS 300/300V Twisted Copper-cored PVC Insulated Cords for Internal Wiring of Equipment Table 7 AVVR 300/300V Copper-cored PVC Insulated and Sheathed PVC cords for Internal Wiring of Equipment Table 8 Inspection
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
JB/T 8734.4-2016, JB 8734.4-2016, JBT 8734.4-2016, JB/T8734.4-2016, JB/T 8734.4, JB/T8734.4, JB8734.4-2016, JB 8734.4, JB8734.4, JBT8734.4-2016, JBT 8734.4, JBT8734.4