JB/T 9548.4-1999 Methods for chemical analysis of iron-chromium-aluminium alloys The photometric acid dehydration gravimetric mehtod for the determination of silicon content (English Version)
Methods for chemical analysis of iron-chromium-aluminium alloys The photometric acid dehydration gravimetric mehtod for the determination of silicon content
This standard specifies the photometric acid dehydration gravimetric method for the determination of silicon content in iron-chromium-aluminium alloys.
This standard is applicable to the determination of silicon content in iron-chromium-aluminium alloys, and the determination range is from 0.10% to 1.00%.
2 Method Summary
The test portion will be dissolved in acid, and will be heated with perchloric acid and smoke to dehydrate the silicic acid, the silicic acid will be filtered, washed and burnt into silicon dioxide. The silicon will be treated with sulfuric acid-hydrofluoric acid to become into silicon tetrafluoride, and the silicon tetrafluoride will evaporate to remove the silicon, hereby, the percentage content of silicon can be calculated according to the difference in mass before and after removing silicon.
JB/T 9548.4-1999 Methods for chemical analysis of iron-chromium-aluminium alloys The photometric acid dehydration gravimetric mehtod for the determination of silicon content (English Version)
Standard No.
JB/T 9548.4-1999
Status
valid
Language
English
File Format
PDF
Word Count
2000 words
Price(USD)
164.0
Implemented on
2000-1-1
Delivery
via email in 1 business day
Detail of JB/T 9548.4-1999
Standard No.
JB/T 9548.4-1999
English Name
Methods for chemical analysis of iron-chromium-aluminium alloys The photometric acid dehydration gravimetric mehtod for the determination of silicon content
1 Scope
This standard specifies the photometric acid dehydration gravimetric method for the determination of silicon content in iron-chromium-aluminium alloys.
This standard is applicable to the determination of silicon content in iron-chromium-aluminium alloys, and the determination range is from 0.10% to 1.00%.
2 Method Summary
The test portion will be dissolved in acid, and will be heated with perchloric acid and smoke to dehydrate the silicic acid, the silicic acid will be filtered, washed and burnt into silicon dioxide. The silicon will be treated with sulfuric acid-hydrofluoric acid to become into silicon tetrafluoride, and the silicon tetrafluoride will evaporate to remove the silicon, hereby, the percentage content of silicon can be calculated according to the difference in mass before and after removing silicon.