2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JGJ 8-2007
JGJ 8-2007   Code for deformation measurement of building and structure (English Version)
Standard No.: JGJ 8-2007 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 26000 words Translation Price(USD):650.0 remind me the price change

Email:

Implemented on:2008-3-1 Delivery: via email in 1 business day

→ → →

,2016-12-1,2008-3-1,14113754854592FA5A8A4ADE77C47
Standard No.: JGJ 8-2007
English Name: Code for deformation measurement of building and structure
Chinese Name: 建筑变形测量规范
Chinese Classification: P13    Engineering location, hydrogeological survey and geotechnical engineering
Professional Classification: JG    Professional Standard - Building
Source Content Issued by: Ministry of Construction
Issued on: 2007-09-04
Implemented on: 2008-3-1
Status: superseded
Superseded by:JGJ 8-2016 Code for Deformation Measurement of Building and Structure
Superseded on:2016-12-1
Superseding:JGJ/T 8-1997 Verification Specification for Deformation Measurement of Building and Structure
Target Language: English
File Format: PDF
Word Count: 26000 words
Translation Price(USD): 650.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This code is formulated with the view to go through with the national policies during deformation measurement of building and structure, to maintain the state-of-art technology, safety and usability, safety and usability, as well as to guarantee quality. 1.0.2 This code is applicable to the settlement measurement, displacement measurement and special deformation measurement of subgrade, foundation, superstructure and field of industrial and civil buildings. 1.0.3 Deformation measurement of building and structure shall be able to exactly reflect the extent or trend of deformation of the building subgrade, foundation, superstructure and field under effect of static load or dynamic load and environment. 1.0.4 Instrument and equipment used for the deformation measurement of building and structure must be verified and qualified. Verification, inspection and maintenance of instrument and equipment shall comply with related national standards. 1.0.5 Besides the methods specified in this code, other methods meeting the technology quality requirements also may be adopted. 1.0.6 Not only this code but also the related national standards shall be complied with for the deformation measurement of building and structure. 2 Terms, Symbols and Code Name 2.1 Terms 2.1.1 Deformation of building and structure It is referred to shape or position changes of subgrade, foundation, superstructure and field of building and structure under all kinds of acting forces. 2.1.2 Deformation measurement of building and structure It is referred to the measurement on shape or position changes of subgrade, foundation, superstructure and the field of building and structure under all kinds of acting forces, and also treatment and analyses works on the results. 2.1.3 Foundation soils, subgrade It is referred to soil body or rock body bearing the foundation. 2.1.4 Foundation It refers to a part of structure, which transfers all kinds of acting forces bear by structure to the subgrade. 2.1.5 Foundation pit It is referred to the room below the ground, which is excavated for construction of building foundation and basement. 2.1.6 Rebound of foundation pit It is referred to the phenomena of soil at pit bottom upswelling owing to unloading the soil self-weight during pit excavation. 2.1.7 Settlement, subsidence It is referred to the vertical movement of building subgrade, foundation and ground under the load action, such as sinking and rising. That sinking or rising amount is named as settlement volume. 2.1.8 Differential settlement The difference of settlement volumes of the same building in the same period but different sections is named as differential settlement. 2.1.9 Adjacent subgrade subsidence It is referred to additional subsidence owing to the redistribution of stress on adjacent foundation soil, which is caused by load difference between the adjacent buildings. 2.1.10 Field ground subsidence
1 General Provisions 2 Terms, Symbols and Code Name 2.1 Terms 2.2 Symbols 2.3 Code Name 3 Basic Requirements 4 Deformation control measurement 4.1 General provisions 4.2 Distribution and measurement of elevation benchmark 4.3 Distribution and measurement of level benchmark 4.4 Leveling 4.5 EDM-trigonometric leveling 4.6 Level Angle Observation 4.7 Distance Observation 4.8 GPS measurement 5 Settlement Observations 5.1 General Provision 5.2 Observation of Building Field Settlement 5.3 Observation of Rebound of Foundation Pit 5.4 Stratified Settlement Observation of Foundation Soil 5.5 Settlement Observation of Building or Structure 6 Displacement Observation 6.1 General Provisions 6.2 Declivity Observation of Building and Structure Main Body 6.3 Horizontal Displacement Observation of Building or Structure 6.4 Lateral Displacement Observation of Foundation Pit Wall 6.5 Landslide Observation of Building Field Landslide 6.6 Deflection Observation 7 Special Deformation Observations 7.1 Dynamic Deformation Measurement 7.2 Sunshine deformation observation 7.3 Wind vibration observation 7.4 Fracture observation 8 Data Processing an Analyzing 8.1 Compensating Computation 8.2 Deformation Geometrical Analysis 8.3 Deformation Modeling and Prediction 9 Outcome Interpretation and Quality Inspection & Acceptance 9.1 Interpretation of Outcome 9.2 Quality Inspection & Acceptance Annex A: Monument and Mark for Elevation Control Point Annex B: Horizontal Displacement Observation Post and Gravity Balancing Ball Mark Annex C: Trigonometrical Leveling Exclusive Target and Fittings Annex D: Marks for Settlement Observation Points Annex E: Outcome Diagram of Settlement Observation Annex F: Outcome Diagram of Displacement and Special Deformation Observation Wording Explanation
JGJ 8-2007 is referred in:
* GB 50497-2009 Technical code for monitoring of building excavation engineering
* GB 50669-2011 Code for construction and acceptance of reinforced concrete silos
* JGJ 6-2011 Technical code for tall building raft foundations and box foundations
* JGJ 3-2010 Technical Specification for Concrete Structures of Tall Building
* GB 50112-2013 Technical code for building in expansive soil regions
* JGJ 6-2011 Technical code for tall building raft foundations and box foundations
* JGJ 3-2010 Technical Specification for Concrete Structures of Tall Building
* GB 50669-2011 Code for construction and acceptance of reinforced concrete silos
* GB 50497-2009 Technical code for monitoring of building excavation engineering
* GB 50497-2009 Technical code for monitoring of building excavation engineering
* GB 50112-2013 Technical code for building in expansive soil regions
* DL/T 5074-2006 Technical Code for Investigation of Geotechnical Engineering of Fossil Fuel Power Plant
Code of China
Standard
JGJ 8-2007  Code for deformation measurement of building and structure (English Version)
Standard No.JGJ 8-2007
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count26000 words
Price(USD)650.0
Implemented on2008-3-1
Deliveryvia email in 1 business day
Detail of JGJ 8-2007
Standard No.
JGJ 8-2007
English Name
Code for deformation measurement of building and structure
Chinese Name
建筑变形测量规范
Chinese Classification
P13
Professional Classification
JG
ICS Classification
93.020
Issued by
Ministry of Construction
Issued on
2007-09-04
Implemented on
2008-3-1
Status
superseded
Superseded by
JGJ 8-2016 Code for Deformation Measurement of Building and Structure
Superseded on
2016-12-1
Abolished on
Superseding
JGJ/T 8-1997 Verification Specification for Deformation Measurement of Building and Structure
Language
English
File Format
PDF
Word Count
26000 words
Price(USD)
650.0
Keywords
JGJ 8-2007, JGJ/T 8-2007, JGJT 8-2007, JGJ8-2007, JGJ 8, JGJ8, JGJ/T8-2007, JGJ/T 8, JGJ/T8, JGJT8-2007, JGJT 8, JGJT8
Introduction of JGJ 8-2007
1 General Provisions 1.0.1 This code is formulated with the view to go through with the national policies during deformation measurement of building and structure, to maintain the state-of-art technology, safety and usability, safety and usability, as well as to guarantee quality. 1.0.2 This code is applicable to the settlement measurement, displacement measurement and special deformation measurement of subgrade, foundation, superstructure and field of industrial and civil buildings. 1.0.3 Deformation measurement of building and structure shall be able to exactly reflect the extent or trend of deformation of the building subgrade, foundation, superstructure and field under effect of static load or dynamic load and environment. 1.0.4 Instrument and equipment used for the deformation measurement of building and structure must be verified and qualified. Verification, inspection and maintenance of instrument and equipment shall comply with related national standards. 1.0.5 Besides the methods specified in this code, other methods meeting the technology quality requirements also may be adopted. 1.0.6 Not only this code but also the related national standards shall be complied with for the deformation measurement of building and structure. 2 Terms, Symbols and Code Name 2.1 Terms 2.1.1 Deformation of building and structure It is referred to shape or position changes of subgrade, foundation, superstructure and field of building and structure under all kinds of acting forces. 2.1.2 Deformation measurement of building and structure It is referred to the measurement on shape or position changes of subgrade, foundation, superstructure and the field of building and structure under all kinds of acting forces, and also treatment and analyses works on the results. 2.1.3 Foundation soils, subgrade It is referred to soil body or rock body bearing the foundation. 2.1.4 Foundation It refers to a part of structure, which transfers all kinds of acting forces bear by structure to the subgrade. 2.1.5 Foundation pit It is referred to the room below the ground, which is excavated for construction of building foundation and basement. 2.1.6 Rebound of foundation pit It is referred to the phenomena of soil at pit bottom upswelling owing to unloading the soil self-weight during pit excavation. 2.1.7 Settlement, subsidence It is referred to the vertical movement of building subgrade, foundation and ground under the load action, such as sinking and rising. That sinking or rising amount is named as settlement volume. 2.1.8 Differential settlement The difference of settlement volumes of the same building in the same period but different sections is named as differential settlement. 2.1.9 Adjacent subgrade subsidence It is referred to additional subsidence owing to the redistribution of stress on adjacent foundation soil, which is caused by load difference between the adjacent buildings. 2.1.10 Field ground subsidence
Contents of JGJ 8-2007
1 General Provisions 2 Terms, Symbols and Code Name 2.1 Terms 2.2 Symbols 2.3 Code Name 3 Basic Requirements 4 Deformation control measurement 4.1 General provisions 4.2 Distribution and measurement of elevation benchmark 4.3 Distribution and measurement of level benchmark 4.4 Leveling 4.5 EDM-trigonometric leveling 4.6 Level Angle Observation 4.7 Distance Observation 4.8 GPS measurement 5 Settlement Observations 5.1 General Provision 5.2 Observation of Building Field Settlement 5.3 Observation of Rebound of Foundation Pit 5.4 Stratified Settlement Observation of Foundation Soil 5.5 Settlement Observation of Building or Structure 6 Displacement Observation 6.1 General Provisions 6.2 Declivity Observation of Building and Structure Main Body 6.3 Horizontal Displacement Observation of Building or Structure 6.4 Lateral Displacement Observation of Foundation Pit Wall 6.5 Landslide Observation of Building Field Landslide 6.6 Deflection Observation 7 Special Deformation Observations 7.1 Dynamic Deformation Measurement 7.2 Sunshine deformation observation 7.3 Wind vibration observation 7.4 Fracture observation 8 Data Processing an Analyzing 8.1 Compensating Computation 8.2 Deformation Geometrical Analysis 8.3 Deformation Modeling and Prediction 9 Outcome Interpretation and Quality Inspection & Acceptance 9.1 Interpretation of Outcome 9.2 Quality Inspection & Acceptance Annex A: Monument and Mark for Elevation Control Point Annex B: Horizontal Displacement Observation Post and Gravity Balancing Ball Mark Annex C: Trigonometrical Leveling Exclusive Target and Fittings Annex D: Marks for Settlement Observation Points Annex E: Outcome Diagram of Settlement Observation Annex F: Outcome Diagram of Displacement and Special Deformation Observation Wording Explanation
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JGJ 8-2007, JGJ/T 8-2007, JGJT 8-2007, JGJ8-2007, JGJ 8, JGJ8, JGJ/T8-2007, JGJ/T 8, JGJ/T8, JGJT8-2007, JGJT 8, JGJT8