2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JGJ/T 67-2019
JGJ/T 67-2019   Standard for design of office building (English Version)
Standard No.: JGJ/T 67-2019 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 12000 words Translation Price(USD):360.0 remind me the price change

Email:

Implemented on:2020-3-1 Delivery: via email in 1 business day

→ → →

,,2020-3-1,9547D43702969CED1586699313698
Standard No.: JGJ/T 67-2019
English Name: Standard for design of office building
Chinese Name: 办公建筑设计标准
Professional Classification: JG    Professional Standard - Building
Source Content Issued by: MOHURD
Issued on: 2019-11-08
Implemented on: 2020-3-1
Status: valid
Superseding:JGJ 67-2006 Design Code for Office Building
Target Language: English
File Format: PDF
Word Count: 12000 words
Translation Price(USD): 360.0
Delivery: via email in 1 business day
JGJ/T 67-2019 Standard for design of office building 1 General provisions 1.0.1 This standard is developed to implement national technical and economic policies in office building design, standardize design practices, and ensure office buildings are safe, hygienic, functional, and efficient. 1.0.2 This standard is applicable to the design of newly constructed, expanded, and renovated office buildings. 1.0.3 Office buildings shall be classified based on their usage requirements and shall meet the requirements of Table 1.0.3: Table 1.0.3 Classification of office buildings Class Example Design service life Class A Particularly important office buildings 100 years or 50 years Class B Important office buildings 50 years Class C General office buildings 50 years or 25 years 1.0.4 When designing office buildings, the principles of land conservation, energy efficiency, water conservation, material conservation and environmental protection shall be followed. 1.0.5 Office buildings shall incorporate accessibility design and meet the relevant requirements of the current national standard GB 50763 Codes for accessibility design. 1.0.6 In addition to complying with this standard, the design of office buildings shall also meet the requirements of other current relevant standards of the nation. 2 Terms 2.0.1 office building buildings used by government agencies, organizations, enterprises, and public institutions to handle administrative affairs and engage in various business activities 2.0.2 multiple-use office building public buildings comprising of office floors and floors with other functionalities 2.0.3 business office building office buildings primarily used for business purposes, consisting of one or more types of office spaces under unified property management 2.0.4 open office space large-space office layout with flexible partitioning options 2.0.5 semi-open office space office space layout that combines open office space with office space in single module 2.0.6 unit-typed office space relatively independent office space layout consisting of reception spaces, office spaces, dedicated toilets, and service spaces 2.0.7 office space in single module independent office space layout consisting of one (or several) bays, partitioned based on a single depth module 3 Site and general layout 3.1 Site 3.1.1 The sites selected for constructing office buildings shall meet the requirements of the local overall plan for land utilization and the urban-rural planning. 3.1.2 Preferably, the sites selected for constructing office buildings shall be located in areas with favorable engineering geology and hydrogeology conditions, well-developed municipal facilities, and convenient access to transportation and communication. 3.1.3 The distance between office building sites and locations containing flammable or explosive materials, as well as sources of noise, dust and smoke, or harmful gas emissions, shall meet the requirements of relevant current standards of the nation on safety, health, and environmental protection. 3.1.4 Class A office buildings shall have at least two sides directly adjacent to urban roads or highways; Class B office buildings shall have at least one side directly adjacent to urban roads or highways, or a pathway connected to urban roads or highways; Class C office buildings should ideally have at least one side directly adjacent to urban roads or highways. 3.1.5 Large office building complexes shall include open spaces within the site for gathering and dispersal of people, serving as emergency evacuation areas. 3.2 General layout
1 General provisions 2 Terms 3 Site and general layout 3.1 Site 3.2 General layout 4 Architectural design 4.1 General requirements 4.2 Office space 4.3 Public housing 4.4 Service room 4.5 Equipment room 5 Fire protection design 6 Indoor environment 6.1 Indoor air environment 6.2 Indoor lighting environment 6.3 Indoor acoustic environment 7 Architectural equipment 7.1 Water supply and drainage 7.2 Heating ventilating and air conditioning 7.3 Building electricity 7.4 Building intelligent Explanation of wording in this standard List of quoted standards
Referred in JGJ/T 67-2019:
*GB 50015-2019 Standard for design of building water supply and drainage
*GB 50016-2014(2018)-Provisions Provisions of Code for Fire Protection Design of Buildings
*GB 50034-2013 Standard for lighting design of buildings
*GB 50052-2009 Code for Design Electric Power Supply Systems
*GB 50054-2011 Code for design of low voltage eletrical installations
*GB 50067-2014 Code for fire protection design of garage, motor-repair-shop and parking-area
*GB 50116-2013 Code for design of automatic fire alarm system
*GB 50176-2016 Code for thermal design of civil building
*GB 50189-2015 Design Standard for Energy Efficiency of Public Buildings
*GB 50222-2017 Code for Fire Prevention in Design of Interior Decoration of Buildings
*GB 50314-2015 Standard for design of intelligent building
*GB 50325-2020 Standard for indoor environmental pollution control of civil building engineering
*GB 50343-2012 Technical code for protection of building electronic information system against lightning
*GB 50348-2018 Technisal code for engineering of security and protection system
*GB 50763-2012 Codes for accessibility design
*GB 50788-2012 Technical code for water supply and sewerage of urban
*GB/T 18883-2022 Standards for indoor air quality
*JGJ 25-2010 Code for Design of Archives Buildings
*JGJ 38-2015 Code for Design of Library Buildings
*JGJ 64-2017 Standard for design of dietetic buildings
*JGJ 100-2015 Code for Design of Parking Garage Building
*CJ/T 164-2014 Domestic water-saving devices
Code of China
Standard
JGJ/T 67-2019  Standard for design of office building (English Version)
Standard No.JGJ/T 67-2019
Statusvalid
LanguageEnglish
File FormatPDF
Word Count12000 words
Price(USD)360.0
Implemented on2020-3-1
Deliveryvia email in 1 business day
Detail of JGJ/T 67-2019
Standard No.
JGJ/T 67-2019
English Name
Standard for design of office building
Chinese Name
办公建筑设计标准
Chinese Classification
Professional Classification
JG
ICS Classification
Issued by
MOHURD
Issued on
2019-11-08
Implemented on
2020-3-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
JGJ 67-2006 Design Code for Office Building
Language
English
File Format
PDF
Word Count
12000 words
Price(USD)
360.0
Keywords
JGJ/T 67-2019, JGJ 67-2019, JGJT 67-2019, JGJ/T67-2019, JGJ/T 67, JGJ/T67, JGJ67-2019, JGJ 67, JGJ67, JGJT67-2019, JGJT 67, JGJT67
Introduction of JGJ/T 67-2019
JGJ/T 67-2019 Standard for design of office building 1 General provisions 1.0.1 This standard is developed to implement national technical and economic policies in office building design, standardize design practices, and ensure office buildings are safe, hygienic, functional, and efficient. 1.0.2 This standard is applicable to the design of newly constructed, expanded, and renovated office buildings. 1.0.3 Office buildings shall be classified based on their usage requirements and shall meet the requirements of Table 1.0.3: Table 1.0.3 Classification of office buildings Class Example Design service life Class A Particularly important office buildings 100 years or 50 years Class B Important office buildings 50 years Class C General office buildings 50 years or 25 years 1.0.4 When designing office buildings, the principles of land conservation, energy efficiency, water conservation, material conservation and environmental protection shall be followed. 1.0.5 Office buildings shall incorporate accessibility design and meet the relevant requirements of the current national standard GB 50763 Codes for accessibility design. 1.0.6 In addition to complying with this standard, the design of office buildings shall also meet the requirements of other current relevant standards of the nation. 2 Terms 2.0.1 office building buildings used by government agencies, organizations, enterprises, and public institutions to handle administrative affairs and engage in various business activities 2.0.2 multiple-use office building public buildings comprising of office floors and floors with other functionalities 2.0.3 business office building office buildings primarily used for business purposes, consisting of one or more types of office spaces under unified property management 2.0.4 open office space large-space office layout with flexible partitioning options 2.0.5 semi-open office space office space layout that combines open office space with office space in single module 2.0.6 unit-typed office space relatively independent office space layout consisting of reception spaces, office spaces, dedicated toilets, and service spaces 2.0.7 office space in single module independent office space layout consisting of one (or several) bays, partitioned based on a single depth module 3 Site and general layout 3.1 Site 3.1.1 The sites selected for constructing office buildings shall meet the requirements of the local overall plan for land utilization and the urban-rural planning. 3.1.2 Preferably, the sites selected for constructing office buildings shall be located in areas with favorable engineering geology and hydrogeology conditions, well-developed municipal facilities, and convenient access to transportation and communication. 3.1.3 The distance between office building sites and locations containing flammable or explosive materials, as well as sources of noise, dust and smoke, or harmful gas emissions, shall meet the requirements of relevant current standards of the nation on safety, health, and environmental protection. 3.1.4 Class A office buildings shall have at least two sides directly adjacent to urban roads or highways; Class B office buildings shall have at least one side directly adjacent to urban roads or highways, or a pathway connected to urban roads or highways; Class C office buildings should ideally have at least one side directly adjacent to urban roads or highways. 3.1.5 Large office building complexes shall include open spaces within the site for gathering and dispersal of people, serving as emergency evacuation areas. 3.2 General layout
Contents of JGJ/T 67-2019
1 General provisions 2 Terms 3 Site and general layout 3.1 Site 3.2 General layout 4 Architectural design 4.1 General requirements 4.2 Office space 4.3 Public housing 4.4 Service room 4.5 Equipment room 5 Fire protection design 6 Indoor environment 6.1 Indoor air environment 6.2 Indoor lighting environment 6.3 Indoor acoustic environment 7 Architectural equipment 7.1 Water supply and drainage 7.2 Heating ventilating and air conditioning 7.3 Building electricity 7.4 Building intelligent Explanation of wording in this standard List of quoted standards
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JGJ/T 67-2019, JGJ 67-2019, JGJT 67-2019, JGJ/T67-2019, JGJ/T 67, JGJ/T67, JGJ67-2019, JGJ 67, JGJ67, JGJT67-2019, JGJT 67, JGJT67