2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JJF 1190-2008
JJF 1190-2008   Calibration Specification for Airborne Particle Counter (English Version)
Standard No.: JJF 1190-2008 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 10500 words Translation Price(USD):260.0 remind me the price change

Email:

Implemented on:2008-9-24 Delivery: via email in 1 business day

→ → →

,,2008-9-24,14113763048873040291792229A9D
Standard No.: JJF 1190-2008
English Name: Calibration Specification for Airborne Particle Counter
Chinese Name: 尘埃粒子计数器校准规范
Chinese Classification: A61    Chemical Measurement
Professional Classification: JJ    Metering
ICS Classification: 17.180.30 17.180.30    Optical measuring instruments 17.180.30
Source Content Issued by: AQSIQ
Issued on: 2008-03-24
Implemented on: 2008-9-24
Status: valid
Superseding:JJG 547-1988 Dust Particles Counter
Target Language: English
File Format: PDF
Word Count: 10500 words
Translation Price(USD): 260.0
Delivery: via email in 1 business day
1 Scope This specification is applicable to the calibration of light-scattering laser airborne particle counter (hereinafter referred to as particle counter). 2 Terms 2.1 monodisperse particle a batch of polystyrene spherical particles with a relative standard deviation of particle diameter ≤ 5%, see Annex A 2.2 particle size diameter of a certain kind of disperse particles in the air (abbreviated as particle size), is the diameter of a certain monodisperse particle corresponding to the intensity of the scattered light, in units of μm, the particle size measured with particle counter is within (0.1~10)μm 2.3 particle concentration quantity of disperse particles with diameter not less than the designated diameter exist in the measured air per unit volume within the specified sampling flow rate and sampling time 2.4 error of particle size error of measurement for percentage of particles in different sizes with particle counter in the aerosol 3 General Particle counter is the instrument that measures the size of discrete particles and the particle concentration in clean air to determine the cleanliness class of clean room and clean environment. The airborne particle counter may also be used for the measurement of dust content in the air, as well as the performance testing of clean bench and filter. The particle counter is mainly composed of pneumatic system, optical system, data processing system, etc. The working principle is that the particles in the air have a scattering effect on the incident light, and the intensity of the scattered light is related to the particle size. The air containing airborne particles is sucked from the sampling port of the airborne particle counter, when passing through the light sensitive area, the airborne particles are scattered into the optical pulse signals which are proportional to the particle size under light irradiation, and the signal is accepted by the photosensor and converted into corresponding electric pulse signal which is amplified again, and the number of airborne particles in the sample air per unit volume, that is, the particle concentration, may be known by counting the electric pulse in one testing period. 4 Metrological Characteristics
Foreword i 1 Scope 2 Terms 3 General 4 Metrological Characteristics 4.1 Appearance Requirements 4.2 Insulation Resistance 4.3 Electrical Strength 4.4 Self-cleaning Time 4.5 Error of Flow Rate 4.6 Timing Error 4.7 Repeatability 4.8 Error of Particle Size 4.9 Particle Concentration Indicated Value Error 5 Calibration Conditions 5.1 Calibration Environment 5.2 Main Calibration Apparatus 6 Calibration Items and Methods 6.1 Appearance Requirements 6.2 Insulation Resistance 6.3 Electrical Strength 6.4 Self-cleaning Time 6.5 Error of Flow Rate 6.6 Timing Error 6.7 Repeatability 6.8 Error of Particle Size 6.9 Particle Concentration Indicated Value Error 7 Calibration Result Expression 8 Recalibration Time Interval Annex A Dilution and Storage Method of Monodisperse Particle Emulsion Annex B Measuring Device for Airborne Particle Generation Annex C Adjustment for Aerosol Concentration of Monodisperse Particle Annex D Measuring Result Uncertainty Assessment of Particle Concentration Indicated Value Error Annex E Measuring Result Uncertainty Assessment for Error of Particle Size Annex F Original Record Format Annex G Inside Page Format of Calibration Result
JJF 1190-2008 is referred in:
*GB/T 6165-2021 Test method of the performance of high efficiency particulate air filter—Efficiency and resistance
Code of China
Standard
JJF 1190-2008  Calibration Specification for Airborne Particle Counter (English Version)
Standard No.JJF 1190-2008
Statusvalid
LanguageEnglish
File FormatPDF
Word Count10500 words
Price(USD)260.0
Implemented on2008-9-24
Deliveryvia email in 1 business day
Detail of JJF 1190-2008
Standard No.
JJF 1190-2008
English Name
Calibration Specification for Airborne Particle Counter
Chinese Name
尘埃粒子计数器校准规范
Chinese Classification
A61
Professional Classification
JJ
ICS Classification
Issued by
AQSIQ
Issued on
2008-03-24
Implemented on
2008-9-24
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
JJG 547-1988 Dust Particles Counter
Language
English
File Format
PDF
Word Count
10500 words
Price(USD)
260.0
Keywords
JJF 1190-2008, JJF/T 1190-2008, JJFT 1190-2008, JJF1190-2008, JJF 1190, JJF1190, JJF/T1190-2008, JJF/T 1190, JJF/T1190, JJFT1190-2008, JJFT 1190, JJFT1190
Introduction of JJF 1190-2008
1 Scope This specification is applicable to the calibration of light-scattering laser airborne particle counter (hereinafter referred to as particle counter). 2 Terms 2.1 monodisperse particle a batch of polystyrene spherical particles with a relative standard deviation of particle diameter ≤ 5%, see Annex A 2.2 particle size diameter of a certain kind of disperse particles in the air (abbreviated as particle size), is the diameter of a certain monodisperse particle corresponding to the intensity of the scattered light, in units of μm, the particle size measured with particle counter is within (0.1~10)μm 2.3 particle concentration quantity of disperse particles with diameter not less than the designated diameter exist in the measured air per unit volume within the specified sampling flow rate and sampling time 2.4 error of particle size error of measurement for percentage of particles in different sizes with particle counter in the aerosol 3 General Particle counter is the instrument that measures the size of discrete particles and the particle concentration in clean air to determine the cleanliness class of clean room and clean environment. The airborne particle counter may also be used for the measurement of dust content in the air, as well as the performance testing of clean bench and filter. The particle counter is mainly composed of pneumatic system, optical system, data processing system, etc. The working principle is that the particles in the air have a scattering effect on the incident light, and the intensity of the scattered light is related to the particle size. The air containing airborne particles is sucked from the sampling port of the airborne particle counter, when passing through the light sensitive area, the airborne particles are scattered into the optical pulse signals which are proportional to the particle size under light irradiation, and the signal is accepted by the photosensor and converted into corresponding electric pulse signal which is amplified again, and the number of airborne particles in the sample air per unit volume, that is, the particle concentration, may be known by counting the electric pulse in one testing period. 4 Metrological Characteristics
Contents of JJF 1190-2008
Foreword i 1 Scope 2 Terms 3 General 4 Metrological Characteristics 4.1 Appearance Requirements 4.2 Insulation Resistance 4.3 Electrical Strength 4.4 Self-cleaning Time 4.5 Error of Flow Rate 4.6 Timing Error 4.7 Repeatability 4.8 Error of Particle Size 4.9 Particle Concentration Indicated Value Error 5 Calibration Conditions 5.1 Calibration Environment 5.2 Main Calibration Apparatus 6 Calibration Items and Methods 6.1 Appearance Requirements 6.2 Insulation Resistance 6.3 Electrical Strength 6.4 Self-cleaning Time 6.5 Error of Flow Rate 6.6 Timing Error 6.7 Repeatability 6.8 Error of Particle Size 6.9 Particle Concentration Indicated Value Error 7 Calibration Result Expression 8 Recalibration Time Interval Annex A Dilution and Storage Method of Monodisperse Particle Emulsion Annex B Measuring Device for Airborne Particle Generation Annex C Adjustment for Aerosol Concentration of Monodisperse Particle Annex D Measuring Result Uncertainty Assessment of Particle Concentration Indicated Value Error Annex E Measuring Result Uncertainty Assessment for Error of Particle Size Annex F Original Record Format Annex G Inside Page Format of Calibration Result
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JJF 1190-2008, JJF/T 1190-2008, JJFT 1190-2008, JJF1190-2008, JJF 1190, JJF1190, JJF/T1190-2008, JJF/T 1190, JJF/T1190, JJFT1190-2008, JJFT 1190, JJFT1190