2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JJF 1409-2013
JJF 1409-2013   Calibration Specification for the Surface Thermometers (English Version)
Standard No.: JJF 1409-2013 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 9000 words Translation Price(USD):270.0 remind me the price change

Email:

Implemented on:2013-11-13 Delivery: via email in 1 business day

→ → →

,,2013-11-13,14113792767237C57FE308A78C42C
Standard No.: JJF 1409-2013
English Name: Calibration Specification for the Surface Thermometers
Chinese Name: 表面温度计校准规范
Professional Classification: JJ    Metering
Source Content Issued by: AQSIQ
Issued on: 2013-5-13
Implemented on: 2013-11-13
Status: valid
Superseding:JJG 364-1994 Surface Themometer
Target Language: English
File Format: PDF
Word Count: 9000 words
Translation Price(USD): 270.0
Delivery: via email in 1 business day
JJF 1409-2013 Calibration Specification for the Surface Thermometers 1 Scope This specification is applicable to the calibration of surface thermometers with thermocouples as sensing elements in the temperature range from room temperature to 400℃. Calibration of other types of surface thermometers may refer to this specification. 2 Normative references JJG 617-1996 Verification regulation of digital temperature indicators and controllers GB/T 13639 Digital indicators with analogue input for use in industrial-process measurement and control systems For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. 3 General A surface thermometer is an instrument used to measure the temperature of a solid surface, which is composed of a temperature sensor and a digital temperature indicator. The principle of temperature measurement is that the temperature sensing element of surface thermometer temperature sensor is pressed tightly on the surface of measured object, and the surface temperature of measured object is displayed by the indicating instrument. The temperature sensing element is a surface thermocouple, and the indicating instrument generally has the function of automatic temperature compensation at the reference end of the thermocouple. 4 Metrological characteristics 4.1 Appearance 4.1.1 The shape and structure of the surface thermometer shall be intact, and there shall be no defects affecting the measurement accuracy. 4.1.2 The plug-in polarity of the temperature sensor shall be correct, the contact shall be good, and the material of plug-in shall be the same as that of temperature sensing element. 4.1.3 Switch on the power supply of surface thermometer, and the indicating instruments shall display normal. 4.2 Indication error The difference between the indicating value of surface thermometer and the actual temperature is the indication error of surface thermometer. 5 Calibration conditions 5.1 Ambient conditions 5.1.1 Ambient temperature: (23 ± 5)℃, the relative humidity shall not be greater than 85%, or comply with the ambient conditions specified for calibration instruments and equipment. 5.1.2 During the calibration process, the ambient temperature fluctuation shall not exceed 0.5℃. There shall be no environmental factors affecting the measurement results in the calibration laboratory. 5.2 Measurement standard and other equipment 5.2.1 Standard instrument
Foreword II 1 Scope 3 General 4 Metrological characteristics 4.1 Appearance 4.2 Indication error 5 Calibration conditions 5.1 Ambient conditions 5.2 Measurement standard and other equipment 6 Calibration items and methods 6.1 Calibration items 6.2 Calibration methods 7 Expression of calibration results 8 Recalibration time interval Annex A Surface thermometer calibration record reference format Annex B Calibration certificate inside page reference format Annex C Example of uncertainty evaluation of surface thermometer indication error measurement results Annex D Temperature stability of surface temperature source and measurement method of temperature uniformity
Referred in JJF 1409-2013:
*JJG 617-1996 Verification Regulation of Digital Temperaure Indicators and Controllers
*GB/T 13639-2008 Digital indicators with analogue input for use in industrial-process measurement and control systems
Code of China
Standard
JJF 1409-2013  Calibration Specification for the Surface Thermometers (English Version)
Standard No.JJF 1409-2013
Statusvalid
LanguageEnglish
File FormatPDF
Word Count9000 words
Price(USD)270.0
Implemented on2013-11-13
Deliveryvia email in 1 business day
Detail of JJF 1409-2013
Standard No.
JJF 1409-2013
English Name
Calibration Specification for the Surface Thermometers
Chinese Name
表面温度计校准规范
Chinese Classification
Professional Classification
JJ
ICS Classification
Issued by
AQSIQ
Issued on
2013-5-13
Implemented on
2013-11-13
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
JJG 364-1994 Surface Themometer
Language
English
File Format
PDF
Word Count
9000 words
Price(USD)
270.0
Keywords
JJF 1409-2013, JJF/T 1409-2013, JJFT 1409-2013, JJF1409-2013, JJF 1409, JJF1409, JJF/T1409-2013, JJF/T 1409, JJF/T1409, JJFT1409-2013, JJFT 1409, JJFT1409
Introduction of JJF 1409-2013
JJF 1409-2013 Calibration Specification for the Surface Thermometers 1 Scope This specification is applicable to the calibration of surface thermometers with thermocouples as sensing elements in the temperature range from room temperature to 400℃. Calibration of other types of surface thermometers may refer to this specification. 2 Normative references JJG 617-1996 Verification regulation of digital temperature indicators and controllers GB/T 13639 Digital indicators with analogue input for use in industrial-process measurement and control systems For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. 3 General A surface thermometer is an instrument used to measure the temperature of a solid surface, which is composed of a temperature sensor and a digital temperature indicator. The principle of temperature measurement is that the temperature sensing element of surface thermometer temperature sensor is pressed tightly on the surface of measured object, and the surface temperature of measured object is displayed by the indicating instrument. The temperature sensing element is a surface thermocouple, and the indicating instrument generally has the function of automatic temperature compensation at the reference end of the thermocouple. 4 Metrological characteristics 4.1 Appearance 4.1.1 The shape and structure of the surface thermometer shall be intact, and there shall be no defects affecting the measurement accuracy. 4.1.2 The plug-in polarity of the temperature sensor shall be correct, the contact shall be good, and the material of plug-in shall be the same as that of temperature sensing element. 4.1.3 Switch on the power supply of surface thermometer, and the indicating instruments shall display normal. 4.2 Indication error The difference between the indicating value of surface thermometer and the actual temperature is the indication error of surface thermometer. 5 Calibration conditions 5.1 Ambient conditions 5.1.1 Ambient temperature: (23 ± 5)℃, the relative humidity shall not be greater than 85%, or comply with the ambient conditions specified for calibration instruments and equipment. 5.1.2 During the calibration process, the ambient temperature fluctuation shall not exceed 0.5℃. There shall be no environmental factors affecting the measurement results in the calibration laboratory. 5.2 Measurement standard and other equipment 5.2.1 Standard instrument
Contents of JJF 1409-2013
Foreword II 1 Scope 3 General 4 Metrological characteristics 4.1 Appearance 4.2 Indication error 5 Calibration conditions 5.1 Ambient conditions 5.2 Measurement standard and other equipment 6 Calibration items and methods 6.1 Calibration items 6.2 Calibration methods 7 Expression of calibration results 8 Recalibration time interval Annex A Surface thermometer calibration record reference format Annex B Calibration certificate inside page reference format Annex C Example of uncertainty evaluation of surface thermometer indication error measurement results Annex D Temperature stability of surface temperature source and measurement method of temperature uniformity