2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JTG F80-2-2004
JTG F80-2-2004   Quality Inspection and Evaluation Standards for Highway Engineering - Volume 2: Mechanical and electrical Engineering (English Version)
Standard No.: JTG F80-2-2004 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 26000 words Translation Price(USD):520.0 remind me the price change

Email:

Implemented on:2005-1-1 Delivery: via email in 1 business day

→ → →

,,2005-1-1,14113743248752502097B172DF765
Standard No.: JTG F80-2-2004
English Name: Quality Inspection and Evaluation Standards for Highway Engineering - Volume 2: Mechanical and electrical Engineering
Chinese Name: 公路工程质量检验评定标准 第二册: 机电工程
Chinese Classification: P66    Highway engineering
Professional Classification: JT    Professional Standard - Transport
Source Content Issued by: Ministry of Transport
Issued on: 2004-09-04
Implemented on: 2005-1-1
Status: valid
Superseding:JTJ 071-1998 Quality Inspection and Evaluation Standards for Highway Engineering
Target Language: English
File Format: PDF
Word Count: 26000 words
Translation Price(USD): 520.0
Delivery: via email in 1 business day
1.0.1 Except for the provisions of this chapter, chapter 1, 2 and 3 of “Quality Inspection and Evaluation Standards for Highway Engineering” (Volume 1: Civil Engineering) is applicable to this volume. 1.0.2 This volume is applicable to mechanical and electrical works in the new, reconstructed and extended traffic engineering projects of expressways. The highway mechanical and electrical works of other highway projects can be implemented with reference to the provisions hereof. 1.0.3 The Inspection frequency of the sub-divisional work of mechanical and electrical engineering: construction organization: 100%; supervision organization: not lower than 30%. The complete inspection shall be performed if the quantity of measuring point is less than 3. 1.0.4 The weight value of the measured and inspected items in the sub-divisional work of the mechanical and electrical engineering is 1. 1.0.5 As for the mechanical and electrical projects evaluated according to this standard, they shall have true and basically complete quality assurance materials. The equipments, raw materials, semi-finished goods and finished goods shall all meet the requirements of the related standards, codes and contracts, and shall be equipped with the inspection certificates, quality certificates issued by the governmentally ratified inspection institutions.
1 General Provision 2 Monitoring Facilities 2.1 Vehicle Detector 2.2 Weather Detectors 2.3 Closed-circuit Television Supervisory System 2.4 Variable Marks 2.5 Optical Cable Line and Cable Line 2.6 Equipment Installation and System Testing At the Monitoring Centre 2.7 Large-screen Projection System 2.8 Map Board 2.9 Computer Network of the Monitoring System 3 Communication Facilities 3.1 Communication Pipelines, Optical Cable Lines and Cable Lines 3.2 Optical Fiber Digital Transmission System 3.3 Digital stored program controlled switching system 3.4 Emergency Telephone System 3.5 Wireless Mobile Communication System 3.6 Communication power sources 4 Toll Facilities 4.1 Entrance Driveway Equipments 4.2 Exit Driveway Equipments 4.3 Toll station equipments and software 4.4 Toll center equipments and software 4.5 IC card sending and coding system 4.6 Internal Wired Talkback and Urgent Alarm System 4.7 Closed-circuit Television Supervisory System 4.8 Optical cables, Cables and Plastic Pipes inside the Toll Station 4.9 Toll System Computer Network 5 Low-voltage Distribution Facilities 5.1 Low-voltage Distribution Equipments for Center Station 5.2 Power Cable Lines of Equipments in Outfield 6 Lighting Facilities 6.0.1 Basic Requirements 6.0.2 Actual Measuring Items 6.0.3 Appearance Evaluation 7 Tunnel electromechanical facilities 7.1 Vehicle Detector 7.2 Weather Detectors 7.3 Closed-circuit Television Supervisory System 7.4 Emergency telephone system 7.5 Environment testing equipments 7.6 Alarm and Inducement Facilities 7.7 Variable Marks 7.8 Ventilation Facilities 7.9 Lighting Facilities 7.10 Fire Fighting Devices 7.11 Local Controller 7.12 Equipments and Software for Tunnel Monitoring Centre 7.13 Computer network in the tunnel monitoring centre 7.14 Low voltage power supply and distribution Appendix A: Inspection and Evaluation for Trial-Operation on Communication Pipes Appendix B Wording Explanation
Code of China
Standard
JTG F80-2-2004  Quality Inspection and Evaluation Standards for Highway Engineering - Volume 2: Mechanical and electrical Engineering (English Version)
Standard No.JTG F80-2-2004
Statusvalid
LanguageEnglish
File FormatPDF
Word Count26000 words
Price(USD)520.0
Implemented on2005-1-1
Deliveryvia email in 1 business day
Detail of JTG F80-2-2004
Standard No.
JTG F80-2-2004
English Name
Quality Inspection and Evaluation Standards for Highway Engineering - Volume 2: Mechanical and electrical Engineering
Chinese Name
公路工程质量检验评定标准 第二册: 机电工程
Chinese Classification
P66
Professional Classification
JT
ICS Classification
Issued by
Ministry of Transport
Issued on
2004-09-04
Implemented on
2005-1-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
JTJ 071-1998 Quality Inspection and Evaluation Standards for Highway Engineering
Language
English
File Format
PDF
Word Count
26000 words
Price(USD)
520.0
Keywords
JTG F80-2-2004, JTG/T F80-2-2004, JTGT F80-2-2004, JTGF80-2-2004, JTG F80, JTGF80, JTG/TF80-2-2004, JTG/T F80, JTG/TF80, JTGTF80-2-2004, JTGT F80, JTGTF80
Introduction of JTG F80-2-2004
1.0.1 Except for the provisions of this chapter, chapter 1, 2 and 3 of “Quality Inspection and Evaluation Standards for Highway Engineering” (Volume 1: Civil Engineering) is applicable to this volume. 1.0.2 This volume is applicable to mechanical and electrical works in the new, reconstructed and extended traffic engineering projects of expressways. The highway mechanical and electrical works of other highway projects can be implemented with reference to the provisions hereof. 1.0.3 The Inspection frequency of the sub-divisional work of mechanical and electrical engineering: construction organization: 100%; supervision organization: not lower than 30%. The complete inspection shall be performed if the quantity of measuring point is less than 3. 1.0.4 The weight value of the measured and inspected items in the sub-divisional work of the mechanical and electrical engineering is 1. 1.0.5 As for the mechanical and electrical projects evaluated according to this standard, they shall have true and basically complete quality assurance materials. The equipments, raw materials, semi-finished goods and finished goods shall all meet the requirements of the related standards, codes and contracts, and shall be equipped with the inspection certificates, quality certificates issued by the governmentally ratified inspection institutions.
Contents of JTG F80-2-2004
1 General Provision 2 Monitoring Facilities 2.1 Vehicle Detector 2.2 Weather Detectors 2.3 Closed-circuit Television Supervisory System 2.4 Variable Marks 2.5 Optical Cable Line and Cable Line 2.6 Equipment Installation and System Testing At the Monitoring Centre 2.7 Large-screen Projection System 2.8 Map Board 2.9 Computer Network of the Monitoring System 3 Communication Facilities 3.1 Communication Pipelines, Optical Cable Lines and Cable Lines 3.2 Optical Fiber Digital Transmission System 3.3 Digital stored program controlled switching system 3.4 Emergency Telephone System 3.5 Wireless Mobile Communication System 3.6 Communication power sources 4 Toll Facilities 4.1 Entrance Driveway Equipments 4.2 Exit Driveway Equipments 4.3 Toll station equipments and software 4.4 Toll center equipments and software 4.5 IC card sending and coding system 4.6 Internal Wired Talkback and Urgent Alarm System 4.7 Closed-circuit Television Supervisory System 4.8 Optical cables, Cables and Plastic Pipes inside the Toll Station 4.9 Toll System Computer Network 5 Low-voltage Distribution Facilities 5.1 Low-voltage Distribution Equipments for Center Station 5.2 Power Cable Lines of Equipments in Outfield 6 Lighting Facilities 6.0.1 Basic Requirements 6.0.2 Actual Measuring Items 6.0.3 Appearance Evaluation 7 Tunnel electromechanical facilities 7.1 Vehicle Detector 7.2 Weather Detectors 7.3 Closed-circuit Television Supervisory System 7.4 Emergency telephone system 7.5 Environment testing equipments 7.6 Alarm and Inducement Facilities 7.7 Variable Marks 7.8 Ventilation Facilities 7.9 Lighting Facilities 7.10 Fire Fighting Devices 7.11 Local Controller 7.12 Equipments and Software for Tunnel Monitoring Centre 7.13 Computer network in the tunnel monitoring centre 7.14 Low voltage power supply and distribution Appendix A: Inspection and Evaluation for Trial-Operation on Communication Pipes Appendix B Wording Explanation
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JTG F80-2-2004, JTG/T F80-2-2004, JTGT F80-2-2004, JTGF80-2-2004, JTG F80, JTGF80, JTG/TF80-2-2004, JTG/T F80, JTG/TF80, JTGTF80-2-2004, JTGT F80, JTGTF80