2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/QB/T 4982-2016
QB/T 4982-2016   Negative ion generator for household and similar electrical appliances (English Version)
Standard No.: QB/T 4982-2016 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 8500 words Translation Price(USD):210.0 remind me the price change

Email:

Implemented on:2017-1-1 Delivery: via email in 1 business day

→ → →

,2024-7-1,2017-1-1,EC41C6DAD2F9A3D91471307412892
Standard No.: QB/T 4982-2016
English Name: Negative ion generator for household and similar electrical appliances
Chinese Name: 家用和类似用途电器用负离子发生器
Chinese Classification: Y62    Household cleaning and cosmetic appliances
Professional Classification: QB    Professional Standard - Light Industry
Source Content Issued by: MIIT
Issued on: 2016-07-11
Implemented on: 2017-1-1
Status: superseded
Superseded by:QB/T 4982-2023 Negative ion generator for household and similar electrical appliances
Superseded on:2024-7-1
Target Language: English
File Format: PDF
Word Count: 8500 words
Translation Price(USD): 210.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by China National Light Industry Council. This national standard is under the jurisdiction of the National Technical Committee on Household Appliances of Standardization Administration of China (SAC/TC 46). This standard is issued as first edition. Negative Ion Generator for Household and Similar Electrical Appliances 1 Scope This standard specifies the terms and definitions, classification and designation, requirements, test methods, inspection rules, marking, packaging, transportation and storage of negative ion generator for household and similar electrical appliances. This standard is applicable to negative ion generator for household and similar electrical appliances, with single-phase rated input voltage not exceeding 250V and other rated input voltage not exceeding 480V. This standard is not applicable to the individually used negative ion generator. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 1019 General Requirements for the Package of Household and Similar Electrical Appliances GB/T 2423.10 Environmental Testing for Electric and Electronic Products - Part 2: Tests Methods - Test Fc: Vibration (Sinusoidal) GB/T 2828.1 Sampling Procedures for Inspection by Attributes - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for Lot-by-lot Inspection" GB/T 2829 Sampling Procedures and Tables for Periodic Inspection by Attributes (Apply to Inspection of Process Stability) GB/T 3667.1-2005 AC Motor Capacitors - Part 1: General - Performance, Testing and Rating - Safety Requirements - Guide for Installation and Operation GB 4706.1-2005 Household and Similar Electrical Appliances Safety - Part 1: General Requirements GB 5296.2 Instructions for Use of Products of Consumer Interest - Part 2: Household and Similar Electrical Appliances GB/T 16292 Test Method for Airborne Particles in Clean Room (Area) of the Pharmaceutical Industry GB/T 18801 Air Cleaner GB/T 18809 General Specification for Air Ion Measuring Instruments 3 Terms and Definitions For the purpose of this document, the following terms and definitions apply. 3.1 negative air ion individual gas molecule or multiple molecular group, with negative charge, hereinafter referred to as “negative air ion” 3.2 negative ion generator device which continuously generates negative ion in air by discharging, hereinafter referred to as “generator” 3.3 negative ion density quantity of negative ions in unit volume of air Note: unit: g/cm3. 3.4 emitter medium in generator, used for air discharge 3.5 working voltage of emitter voltage-to-earth measured for negative ion emitter on voltmeter with input impedance of 1kMΩ 4 Classification and Designation See Annex A for classification and designation of generator. 5 Requirements 5.1 Appearance 5.1.1 The casing of generator shall be in good condition, free of deformation and sharp corner. 5.1.2 The surface of conductor and sheath shall be clean, free of dirt or damage 5.1.3 Coating should be uniform in color, free of odor, scratches, peeling, damaged matt surface, pores, roughness, leakage, etc. 5.1.4 Circuit shall be packaged well and fixed reliably. 5.2 Safety requirements 5.2.1 Heating Generator and its ambient environment shall not reach excessive temperature in normal use. Temperature rise shall be monitored continuously during the test. The temperature rise shall not exceed the value shown in Table 3 in Chapter 11, GB 4706.1-2005. The protective device shall not act and the sealant shall not flow out. 5.2.2 Leakage current At working temperature, the generator continues to work to the stable state specified in 6.3.2, and the leakage current shall not exceed the following values: ——For Class II structure: 0.25mA; ——For Class III structure: 0.5mA. 5.2.3 Protection against access to live parts The structure and casing of the generator shall be adequate to protect against accidental access to live parts. Note: parts that are powered by a safe ultra-low voltage are not applicable. 5.2.4 Electrical strength Where tested according to 6.3.4, no breakdown shall occur. 5.2.5 Moisture resistance After being subject to the test specified in 6.3.5, the generator, where under electrical strength test according to 6.3.4, shall be free from of breakdown. 5.2.6 Vibration resistance After being subject to the test specified in 6.3.6, the generator, where under electrical strength test according to 6.3.4, shall be free from of breakdown. 5.2.7 Installation strength Generator shall be provided with enough installation strength, of which the surface shall be free from visible damage after being subject to the test according to 6.3.7. 5.2.8 Ozone concentration Where tested according to the requirements of Annex B, the ozone concentration generated by the generator shall not exceed 0.10mg/m3.
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Designation 5 Requirements 6 Test Methods 7 Inspection Rules 8 Marking, Packaging, Transportation and Storage Annex A (Informative) Classification and Designation Annex B (Normative) Test Method for Ozone Concentration Annex C (Normative) Test Method for Concentration of Negative Ion
Referred in QB/T 4982-2016:
*GB/T 1019-2008 General requirements for the package of household and similar electrical appliances
*GB/T 2423.10-2019 Environmental testing—Part 2:Test methods—Test Fc: Vibration (sinusoidal)
*GB/T 2828.1-2012 Sampling procedures for inspection by attributea-Part1:Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
*GB/T 2829-2002 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability)
*GB/T 3667.1-2005 AC motor capacitors - Part 1: General - Performance, testing and rating - Safety requirements - install and run Guidelines
*GB 4706.1-2005 Household and Similar Electrical Appliances – Safety - Part 1: General Requirements
*GB 5296.2-2008 Instructions for use of products of consumer interest - Part 2: Household and similar electrical appliances
*GB/T 16292-2010 Test method for airborne particles in clean room(zone) of the pharmaceutical industry
*GB/T 18801-2022 Air cleaner
*GB/T 18809-2019 General specification for air ion measuring instruments
QB/T 4982-2016 is referred in:
*16G101-3 Drawing Rules and Standard Detailing Drawings of Ichnographic Representing Method for Construction Drawings of R.C. Structures (Spread Footings, Strip Foundations, Raft Foundations and Pile Foundations)
*16G101-1 Drawing Rules and Standard Detailing Drawings of Ichnographic Representing Method for Construction Drawings of R.C. Structures (Cast-in-situ R.C. frames, shear walls, beams and slabs)
*16G101-2 Drawing Rules and Standard Detailing Drawings of Ichnographic Representing Method for Construction Drawings of R.C. Structures (Cast-in-situ Concrete Slab-stairs)
*HG/T 4997-2016 Determination of pull-out force of eyelets
*China RoHS2 Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products
*GB 4806.2-2015 National food safety standard — Nipple
*JIANKE2015-108 Technical Guidelines for Assessment of Green Building 2015
*GB 3633-1983 Technical requirements for sets of torshear type high strength bolt hexagon nut and plain washer for steel structures
*JTBL1999-5 Rules of Automobile Freight Transportation -(Decree No.5 [1999] of the Ministry of Communications)
*YD/T 3168-2016 Radio frequency technical requirement and test method for public wireless LAN equipment
*HDB/FZ100-2012
*HDB/FZ 104-2013 Made of cotton and chemical fiber belts, conveyor and processing trade consumption standards
*HDB/FZ070-2011 Standard for Unit Consumption in the Processing Trade of Men's Cotton and Chemical Fibre Knitted Vest
*HDB/FZ056-2009 Standard for Unit Consumption in the Processing Trade of Yarn-Dyed Woven Fabrics Made from Pure Mulberry Silk
*HDB/FZ055-2009 Standard for Unit Consumption in the Processing Trade of Cotton and Syntlhetic Fibre Weft Knitted Fabrics
*HDB/FZ054-2009 Standard for Unit Consumption in the Processing Trade of Linen and Cotton, Artificial Fibre Blended Yarn-Dyed Woven Fabrics (Grey Cloth)
*HDB/FZ053-2009 Standard for Unit Consumption in the Processing Trade of Blenched, Dyed and Printed Woven Fabrics Made from Linen and Cotton, Chemical Fibre Blends
*HDB/FZ052-2009 Standard for Unit Consumption in the Processing Trade of Nylon-6 Fabric Tapes
*HDB/FZ051-2009 Standard for Unit Consumption in the Processing Trade of Combed Wool and Chemical Fibre Blended Woven Fabrics
*HDB/FZ131-2016 Standard for Unit Consumption in the Processing Trade of Chinlon-6 Drawn Single Yarn
*China-RoHS2 Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products
Code of China
Standard
QB/T 4982-2016  Negative ion generator for household and similar electrical appliances (English Version)
Standard No.QB/T 4982-2016
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count8500 words
Price(USD)210.0
Implemented on2017-1-1
Deliveryvia email in 1 business day
Detail of QB/T 4982-2016
Standard No.
QB/T 4982-2016
English Name
Negative ion generator for household and similar electrical appliances
Chinese Name
家用和类似用途电器用负离子发生器
Chinese Classification
Y62
Professional Classification
QB
ICS Classification
Issued by
MIIT
Issued on
2016-07-11
Implemented on
2017-1-1
Status
superseded
Superseded by
QB/T 4982-2023 Negative ion generator for household and similar electrical appliances
Superseded on
2024-7-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
8500 words
Price(USD)
210.0
Keywords
QB/T 4982-2016, QB 4982-2016, QBT 4982-2016, QB/T4982-2016, QB/T 4982, QB/T4982, QB4982-2016, QB 4982, QB4982, QBT4982-2016, QBT 4982, QBT4982
Introduction of QB/T 4982-2016
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by China National Light Industry Council. This national standard is under the jurisdiction of the National Technical Committee on Household Appliances of Standardization Administration of China (SAC/TC 46). This standard is issued as first edition. Negative Ion Generator for Household and Similar Electrical Appliances 1 Scope This standard specifies the terms and definitions, classification and designation, requirements, test methods, inspection rules, marking, packaging, transportation and storage of negative ion generator for household and similar electrical appliances. This standard is applicable to negative ion generator for household and similar electrical appliances, with single-phase rated input voltage not exceeding 250V and other rated input voltage not exceeding 480V. This standard is not applicable to the individually used negative ion generator. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 1019 General Requirements for the Package of Household and Similar Electrical Appliances GB/T 2423.10 Environmental Testing for Electric and Electronic Products - Part 2: Tests Methods - Test Fc: Vibration (Sinusoidal) GB/T 2828.1 Sampling Procedures for Inspection by Attributes - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for Lot-by-lot Inspection" GB/T 2829 Sampling Procedures and Tables for Periodic Inspection by Attributes (Apply to Inspection of Process Stability) GB/T 3667.1-2005 AC Motor Capacitors - Part 1: General - Performance, Testing and Rating - Safety Requirements - Guide for Installation and Operation GB 4706.1-2005 Household and Similar Electrical Appliances Safety - Part 1: General Requirements GB 5296.2 Instructions for Use of Products of Consumer Interest - Part 2: Household and Similar Electrical Appliances GB/T 16292 Test Method for Airborne Particles in Clean Room (Area) of the Pharmaceutical Industry GB/T 18801 Air Cleaner GB/T 18809 General Specification for Air Ion Measuring Instruments 3 Terms and Definitions For the purpose of this document, the following terms and definitions apply. 3.1 negative air ion individual gas molecule or multiple molecular group, with negative charge, hereinafter referred to as “negative air ion” 3.2 negative ion generator device which continuously generates negative ion in air by discharging, hereinafter referred to as “generator” 3.3 negative ion density quantity of negative ions in unit volume of air Note: unit: g/cm3. 3.4 emitter medium in generator, used for air discharge 3.5 working voltage of emitter voltage-to-earth measured for negative ion emitter on voltmeter with input impedance of 1kMΩ 4 Classification and Designation See Annex A for classification and designation of generator. 5 Requirements 5.1 Appearance 5.1.1 The casing of generator shall be in good condition, free of deformation and sharp corner. 5.1.2 The surface of conductor and sheath shall be clean, free of dirt or damage 5.1.3 Coating should be uniform in color, free of odor, scratches, peeling, damaged matt surface, pores, roughness, leakage, etc. 5.1.4 Circuit shall be packaged well and fixed reliably. 5.2 Safety requirements 5.2.1 Heating Generator and its ambient environment shall not reach excessive temperature in normal use. Temperature rise shall be monitored continuously during the test. The temperature rise shall not exceed the value shown in Table 3 in Chapter 11, GB 4706.1-2005. The protective device shall not act and the sealant shall not flow out. 5.2.2 Leakage current At working temperature, the generator continues to work to the stable state specified in 6.3.2, and the leakage current shall not exceed the following values: ——For Class II structure: 0.25mA; ——For Class III structure: 0.5mA. 5.2.3 Protection against access to live parts The structure and casing of the generator shall be adequate to protect against accidental access to live parts. Note: parts that are powered by a safe ultra-low voltage are not applicable. 5.2.4 Electrical strength Where tested according to 6.3.4, no breakdown shall occur. 5.2.5 Moisture resistance After being subject to the test specified in 6.3.5, the generator, where under electrical strength test according to 6.3.4, shall be free from of breakdown. 5.2.6 Vibration resistance After being subject to the test specified in 6.3.6, the generator, where under electrical strength test according to 6.3.4, shall be free from of breakdown. 5.2.7 Installation strength Generator shall be provided with enough installation strength, of which the surface shall be free from visible damage after being subject to the test according to 6.3.7. 5.2.8 Ozone concentration Where tested according to the requirements of Annex B, the ozone concentration generated by the generator shall not exceed 0.10mg/m3.
Contents of QB/T 4982-2016
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Designation 5 Requirements 6 Test Methods 7 Inspection Rules 8 Marking, Packaging, Transportation and Storage Annex A (Informative) Classification and Designation Annex B (Normative) Test Method for Ozone Concentration Annex C (Normative) Test Method for Concentration of Negative Ion
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
QB/T 4982-2016, QB 4982-2016, QBT 4982-2016, QB/T4982-2016, QB/T 4982, QB/T4982, QB4982-2016, QB 4982, QB4982, QBT4982-2016, QBT 4982, QBT4982