2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/TSG 11-2020/XG1-2024
TSG 11-2020/XG1-2024   Regulation on Safety Technology for Boiler,includes Amendment 1 (English Version)
Standard No.: TSG 11-2020/XG1-2024 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 52500 words Translation Price(USD):960.0 remind me the price change

Email:

Implemented on:2025-1-1 Delivery: via email in 1 business day

→ → →

,,2025-1-1,3674B811D7E6AEDE1728691837642
Standard No.: TSG 11-2020/XG1-2024
English Name: Regulation on Safety Technology for Boiler,includes Amendment 1
Chinese Name: 《锅炉安全技术规程》,含行业标准第1号修改单
Professional Classification: TSG    Special Equipment Safety Specification
Source Content Issued by: SAMR
Issued on: 2024-09-26
Implemented on: 2025-1-1
Status: valid
Superseding:TSG 11-2020 Regulation on Safety Technology for Boiler
Target Language: English
File Format: PDF
Word Count: 52500 words
Translation Price(USD): 960.0
Delivery: via email in 1 business day
TSG 11-2020/XG1-2024 Regulation on Safety Technology for Boiler,includes Amendment 1, English, Anglais, Englisch, Inglés, えいご 1 General provisions 1.1 Purpose This Regulation is formulated according to Special equipment safety Law of the People's Republic of China and Regulations on safety supervision of special equipment with a view to ensuring the safe operation of boiler, preventing and reducing accidents, protecting people's life and property safety, and promoting economic and social development. 1.2 Application scope This Regulation is applicable to steam boilers, hot water boilers and organic heat carrier boilers within the scope of Special equipment catalogue. Note 1-1: Heat recovery (waste heat) boilers manufactured according to the boiler design shall meet the requirements of this Regulation. 1.2.1 Boiler body Boiler body is a whole composed of boiler drum (shell), start-up (steam-water) separator, water storage tank, heating surface, header and its connecting pipes, hearth, combustion equipment, air preheater, boiler wall, flue (air duct), frame (including platform and escalator), etc. 1.2.2 Pipes within the boiler range (1) For power station boiler, the pipes include main water supply pipe, main steam pipe, reheat steam pipe, etc. (Note 1-2) and branch pipe within the first valve (excluding valve, the same below); (2) For boilers other than power station boilers, the pipes include pressure-bearing pipes from the outlet of feed water (oil) pump to the first circumferential weld of steam distribution header which connects the external pipes for those arranged with steam (water or oil) distribution header (hereinafter referred to as steam distribution header, Note 1-3) or include the pressure-bearing pipes from the outlet of feed water (oil) pump to the outlet valve of main steam (water or oil) for those not arranged with steam distribution header. Note 1-2: The main water supply pipe refers to the pipe from the check valve at the outlet of feed water pump to the inlet header of economizer; the main steam pipe refers to the pipe from the outlet header of the final superheater to the high-pressure main steam valve of the steam turbine (for pipe-main operating boiler, to the first valve in front of the main pipe); reheat steam cold section pipe refers to the pipe from steam turbine exhaust check valve to reheater inlet header; reheat steam hot section pipe refers to the pipe from the outlet header of the final reheater to the middle-pressure main steam valve of the steam turbine. Note 1-3: The steam distribution header shall be designed and manufactured in accordance with relevant requirements of boiler header or pressure vessel. Note 1-4: The power pipes outside the boiler scope which connect to the boiler may be installed, supervised, inspected and periodically inspected together with the boiler with reference to the requirements for pipes within the boiler range. 1.2.3 Safety accessories and instruments of boiler Safety accessories and instruments of boiler include safety valves, bursting discs, devices (instruments) for pressure measurement, water (liquid) level measurement and temperature measurement, safety protection devices, sewage and water discharge devices, etc. 1.2.4 Auxiliary equipment and system of boiler Auxiliary equipment and system of boiler include fuel preparation and water treatment equipment and systems. 1.3 Exclusions (1) Steam boilers with the designed normal water level water capacity (for concurrent boiler and other boilers without fixed steam-water dividing line, the water capacity shall be calculated according to the geometric total capacity in the inlet and outlet of steam-water system, the same below) than 30L, or with the rated steam pressure less than 0.1MPa; (2) Hot water boilers with rated outlet water pressure less than 0.1MPa or rated thermal power less than 0.1MW; (3) Organic heat carrier boilers with rated thermal power less than 0.1MW. 1.4 Boiler equipment Class According to the parameters, the boiler equipment shall be divided into Classes A, B, C and D. 1.4.1 Class A boiler Class A boilers refer to boilers with p (gauge pressure, the same below, Note 1-5)≥3.8MPa, including: (1) Supercritical boiler, p ≥ 22.1MPa; (2) Subcritical boiler, 16.7MPa ≤ p < 22.1MPa; (3) Superhigh pressure boiler, 13.7 MPa ≤ p < 16.7 MPa; (4) High-pressure boiler, 9.8 MPa ≤ p < 13.7 MPa; (5) Sub-high pressure boiler, 5.3 MPa ≤ p < 9.8 MPa; (6) Medium-pressure boiler, 3.8 MPa ≤ p < 5.3 MPa. 1.4.2 Class B boiler (1) Steam boiler, 0.8MPa < p < 3.8MPa; (2) Hot water boiler, p < 3.8 MPa, and t≥120℃ (t is rated outlet water temperature, the same below); (3) Gas phase organic heat carrier boiler, Q > 0.7 MW (Q is rated thermal power, the same below); liquid phase organic heat carrier boiler, Q > 4.2 MW. 1.4.3 Class C boiler (1) Steam boiler, p≤0.8MPa, and V > 50L (V is the water volume at designed normal water level, the same below); (2) Hot water boiler, 0.4MPa < p < 3.8MPa, and t < 120℃; p≤0.4MPa, and 95℃ < t < 120℃; (3) Gas phase organic heat carrier boiler, Q ≤ 0.7 MW; liquid phase organic heat carrier boiler, Q≤4.2MW. 1.4.4 Class D boiler (1) Steam boiler, p≤0.8MPa and V ≤ 50L; (2) Hot water boiler, p≤0.4MPa and t≤95℃. Note 1-5: p refers to rated working pressure of boiler, which represents the rated steam pressure for steam boiler, the rated outlet water pressure for hot water boiler and the rated outlet pressure for organic heat carrier boiler. 1.5 Boilers for which overseas standards are adopted For boilers for which overseas standards are adopted, the requirements for materials, design, manufacturing and product inspection, safety accessories and instruments, ex-factory documents, nameplate, etc. shall not be lower than the requirements of this Regulation, otherwise, technical review and approval shall be conducted in accordance with the requirements of 1.6 of this Regulation. 1.6 Handling of special cases If the relevant organizations adopt new materials, new technologies and new processes, which are inconsistent with this Regulation or are not required by this Regulation, which may have a significant impact on safety performance, they shall report to the State Administration for Market Regulation which entrusts the Special Equipment Safety and Energy Saving Technical Committee to conduct technical review, and the new materials, new technologies and new processes may be put into production and use only after the review results are approved by the State Administration for Market Regulation. 1.7 Relationship with technical standards and management system This Regulation specifies the basic safety requirements of boilers, and the technical standards and management systems adopted in the production, use, inspection and testing of boilers shall not be lower than the requirements of this Regulation. 1.8 Special requirements The special requirements for hot water boilers, organic heat carrier boilers, cast iron boilers, cast aluminum boilers and Class D boilers shall be implemented in accordance with the requirements of clause 10 of this Regulation and shall be preferentially adopted. 1.9 Other requirements (1) The energy conservation and environmental protection of the boilers shall meet the requirements of laws, regulations, safety technical regulations and relevant standards. (2) The boiler sales unit shall establish and implement the boiler inspection and acceptance and sales record system, and the boilers sold shall meet the requirements of safety technical specifications and relevant standards, and the design documents, product quality certificates and other relevant technical data and documents shall be complete; (3) The manufacturing, installation, modification, repair and using units and inspection institutions of boilers shall timely fill in the information according to the informationization requirements for special equipment. 2 Materials 2.1 Basic requirements
Contents Foreword i 1 General provisions 2 Materials 3 Design 4 Manufacture 5 Safety accessories and instruments 6 Combustion equipment, auxiliary equipment and system 7 Installation, modification and repair 8 Use management 9 Inspection 10 Special requirements 11 Supplementary provisions Annex A Selection of materials for boiler Annex B Product certificate of boilers Annexed table b Annex C Code numbering method for special equipment Annex D Principles for type test model coverage of liquid (gas) fuel burners Annex E Supervision and inspection items of boiler manufacturing Annex F Supervision and inspection items of boiler installation Annex G Certificate for supervision and inspection of boiler Annex H External inspection items of boiler Annex J Internal inspection items of boiler Previous development (revision) of relevant rules and regulations
TSG 11-2020/XG1-2024 is referred in:
*GB/T 16508-2022 锅壳锅炉(合集)
Code of China
Standard
TSG 11-2020/XG1-2024  Regulation on Safety Technology for Boiler,includes Amendment 1 (English Version)
Standard No.TSG 11-2020/XG1-2024
Statusvalid
LanguageEnglish
File FormatPDF
Word Count52500 words
Price(USD)960.0
Implemented on2025-1-1
Deliveryvia email in 1 business day
Detail of TSG 11-2020/XG1-2024
Standard No.
TSG 11-2020/XG1-2024
English Name
Regulation on Safety Technology for Boiler,includes Amendment 1
Chinese Name
《锅炉安全技术规程》,含行业标准第1号修改单
Chinese Classification
Professional Classification
TSG
ICS Classification
Issued by
SAMR
Issued on
2024-09-26
Implemented on
2025-1-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
TSG 11-2020 Regulation on Safety Technology for Boiler
Language
English
File Format
PDF
Word Count
52500 words
Price(USD)
960.0
Keywords
TSG 11-2020/XG1-2024, TSGT 11-2020/XG1-2024, TSGT 11-2020XG1-2024, TSG11-2020/XG1-2024, TSG 11, TSG11, TSGT11-2020/XG1-2024, TSGT 11, TSGT11, TSGT11-2020XG1-2024, TSGT 11, TSGT11
Introduction of TSG 11-2020/XG1-2024
TSG 11-2020/XG1-2024 Regulation on Safety Technology for Boiler,includes Amendment 1, English, Anglais, Englisch, Inglés, えいご 1 General provisions 1.1 Purpose This Regulation is formulated according to Special equipment safety Law of the People's Republic of China and Regulations on safety supervision of special equipment with a view to ensuring the safe operation of boiler, preventing and reducing accidents, protecting people's life and property safety, and promoting economic and social development. 1.2 Application scope This Regulation is applicable to steam boilers, hot water boilers and organic heat carrier boilers within the scope of Special equipment catalogue. Note 1-1: Heat recovery (waste heat) boilers manufactured according to the boiler design shall meet the requirements of this Regulation. 1.2.1 Boiler body Boiler body is a whole composed of boiler drum (shell), start-up (steam-water) separator, water storage tank, heating surface, header and its connecting pipes, hearth, combustion equipment, air preheater, boiler wall, flue (air duct), frame (including platform and escalator), etc. 1.2.2 Pipes within the boiler range (1) For power station boiler, the pipes include main water supply pipe, main steam pipe, reheat steam pipe, etc. (Note 1-2) and branch pipe within the first valve (excluding valve, the same below); (2) For boilers other than power station boilers, the pipes include pressure-bearing pipes from the outlet of feed water (oil) pump to the first circumferential weld of steam distribution header which connects the external pipes for those arranged with steam (water or oil) distribution header (hereinafter referred to as steam distribution header, Note 1-3) or include the pressure-bearing pipes from the outlet of feed water (oil) pump to the outlet valve of main steam (water or oil) for those not arranged with steam distribution header. Note 1-2: The main water supply pipe refers to the pipe from the check valve at the outlet of feed water pump to the inlet header of economizer; the main steam pipe refers to the pipe from the outlet header of the final superheater to the high-pressure main steam valve of the steam turbine (for pipe-main operating boiler, to the first valve in front of the main pipe); reheat steam cold section pipe refers to the pipe from steam turbine exhaust check valve to reheater inlet header; reheat steam hot section pipe refers to the pipe from the outlet header of the final reheater to the middle-pressure main steam valve of the steam turbine. Note 1-3: The steam distribution header shall be designed and manufactured in accordance with relevant requirements of boiler header or pressure vessel. Note 1-4: The power pipes outside the boiler scope which connect to the boiler may be installed, supervised, inspected and periodically inspected together with the boiler with reference to the requirements for pipes within the boiler range. 1.2.3 Safety accessories and instruments of boiler Safety accessories and instruments of boiler include safety valves, bursting discs, devices (instruments) for pressure measurement, water (liquid) level measurement and temperature measurement, safety protection devices, sewage and water discharge devices, etc. 1.2.4 Auxiliary equipment and system of boiler Auxiliary equipment and system of boiler include fuel preparation and water treatment equipment and systems. 1.3 Exclusions (1) Steam boilers with the designed normal water level water capacity (for concurrent boiler and other boilers without fixed steam-water dividing line, the water capacity shall be calculated according to the geometric total capacity in the inlet and outlet of steam-water system, the same below) than 30L, or with the rated steam pressure less than 0.1MPa; (2) Hot water boilers with rated outlet water pressure less than 0.1MPa or rated thermal power less than 0.1MW; (3) Organic heat carrier boilers with rated thermal power less than 0.1MW. 1.4 Boiler equipment Class According to the parameters, the boiler equipment shall be divided into Classes A, B, C and D. 1.4.1 Class A boiler Class A boilers refer to boilers with p (gauge pressure, the same below, Note 1-5)≥3.8MPa, including: (1) Supercritical boiler, p ≥ 22.1MPa; (2) Subcritical boiler, 16.7MPa ≤ p < 22.1MPa; (3) Superhigh pressure boiler, 13.7 MPa ≤ p < 16.7 MPa; (4) High-pressure boiler, 9.8 MPa ≤ p < 13.7 MPa; (5) Sub-high pressure boiler, 5.3 MPa ≤ p < 9.8 MPa; (6) Medium-pressure boiler, 3.8 MPa ≤ p < 5.3 MPa. 1.4.2 Class B boiler (1) Steam boiler, 0.8MPa < p < 3.8MPa; (2) Hot water boiler, p < 3.8 MPa, and t≥120℃ (t is rated outlet water temperature, the same below); (3) Gas phase organic heat carrier boiler, Q > 0.7 MW (Q is rated thermal power, the same below); liquid phase organic heat carrier boiler, Q > 4.2 MW. 1.4.3 Class C boiler (1) Steam boiler, p≤0.8MPa, and V > 50L (V is the water volume at designed normal water level, the same below); (2) Hot water boiler, 0.4MPa < p < 3.8MPa, and t < 120℃; p≤0.4MPa, and 95℃ < t < 120℃; (3) Gas phase organic heat carrier boiler, Q ≤ 0.7 MW; liquid phase organic heat carrier boiler, Q≤4.2MW. 1.4.4 Class D boiler (1) Steam boiler, p≤0.8MPa and V ≤ 50L; (2) Hot water boiler, p≤0.4MPa and t≤95℃. Note 1-5: p refers to rated working pressure of boiler, which represents the rated steam pressure for steam boiler, the rated outlet water pressure for hot water boiler and the rated outlet pressure for organic heat carrier boiler. 1.5 Boilers for which overseas standards are adopted For boilers for which overseas standards are adopted, the requirements for materials, design, manufacturing and product inspection, safety accessories and instruments, ex-factory documents, nameplate, etc. shall not be lower than the requirements of this Regulation, otherwise, technical review and approval shall be conducted in accordance with the requirements of 1.6 of this Regulation. 1.6 Handling of special cases If the relevant organizations adopt new materials, new technologies and new processes, which are inconsistent with this Regulation or are not required by this Regulation, which may have a significant impact on safety performance, they shall report to the State Administration for Market Regulation which entrusts the Special Equipment Safety and Energy Saving Technical Committee to conduct technical review, and the new materials, new technologies and new processes may be put into production and use only after the review results are approved by the State Administration for Market Regulation. 1.7 Relationship with technical standards and management system This Regulation specifies the basic safety requirements of boilers, and the technical standards and management systems adopted in the production, use, inspection and testing of boilers shall not be lower than the requirements of this Regulation. 1.8 Special requirements The special requirements for hot water boilers, organic heat carrier boilers, cast iron boilers, cast aluminum boilers and Class D boilers shall be implemented in accordance with the requirements of clause 10 of this Regulation and shall be preferentially adopted. 1.9 Other requirements (1) The energy conservation and environmental protection of the boilers shall meet the requirements of laws, regulations, safety technical regulations and relevant standards. (2) The boiler sales unit shall establish and implement the boiler inspection and acceptance and sales record system, and the boilers sold shall meet the requirements of safety technical specifications and relevant standards, and the design documents, product quality certificates and other relevant technical data and documents shall be complete; (3) The manufacturing, installation, modification, repair and using units and inspection institutions of boilers shall timely fill in the information according to the informationization requirements for special equipment. 2 Materials 2.1 Basic requirements
Contents of TSG 11-2020/XG1-2024
Contents Foreword i 1 General provisions 2 Materials 3 Design 4 Manufacture 5 Safety accessories and instruments 6 Combustion equipment, auxiliary equipment and system 7 Installation, modification and repair 8 Use management 9 Inspection 10 Special requirements 11 Supplementary provisions Annex A Selection of materials for boiler Annex B Product certificate of boilers Annexed table b Annex C Code numbering method for special equipment Annex D Principles for type test model coverage of liquid (gas) fuel burners Annex E Supervision and inspection items of boiler manufacturing Annex F Supervision and inspection items of boiler installation Annex G Certificate for supervision and inspection of boiler Annex H External inspection items of boiler Annex J Internal inspection items of boiler Previous development (revision) of relevant rules and regulations
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
TSG 11-2020/XG1-2024, TSGT 11-2020/XG1-2024, TSGT 11-2020XG1-2024, TSG11-2020/XG1-2024, TSG 11, TSG11, TSGT11-2020/XG1-2024, TSGT 11, TSGT11, TSGT11-2020XG1-2024, TSGT 11, TSGT11