2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YD/T 1597.1-2007
YD/T 1597.1-2007   Requirements and Measurement Methods of Electromagnetic Compatibility for 2GHz cdma2000 Digital Cellular Mobile Communications System Part 1:User Equipment and Ancillary Equipment (English Version)
Standard No.: YD/T 1597.1-2007 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 9000 words Translation Price(USD):270.0 remind me the price change

Email:

Implemented on:2007-5-16 Delivery: via email in 1~3 business day

→ → →

,,2007-5-16,14113756813162E443C8A9B5386BF
Standard No.: YD/T 1597.1-2007
English Name: Requirements and Measurement Methods of Electromagnetic Compatibility for 2GHz cdma2000 Digital Cellular Mobile Communications System Part 1:User Equipment and Ancillary Equipment
Chinese Name: 2GHz cdma2000数字蜂窝移动通信系统电磁兼容性要求和测量方法 第1部分:用户设备及其辅助设备
Chinese Classification: M37    Mobile communication equipment
Professional Classification: YD    Professional Standard - Telecommunication
ICS Classification: 33.040.01 33.040.01    Telecommunication systems in general 33.040.01
Issued on: 2007-5-16
Implemented on: 2007-5-16
Status: valid
Target Language: English
File Format: PDF
Word Count: 9000 words
Translation Price(USD): 270.0
Delivery: via email in 1~3 business day
1 Scope This part specifies the requirements, including limits, performance criteria and measuring methods, of electromagnetic compatibility (EMC) for user equipment and ancillary equipment of 2GHz cdma2000 digital cellular mobile communications system. This part is applicable to cdma2000 and cdma2000 HRPD user side equipment, including portable and on-board user equipment, for sending and receiving voice and/or data as well as those user equipment powered by AC supply and used in fixed position. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this part. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. GB 9254 Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement GB/T 17618 Information Technology Equipment - Immunity Characteristics - Limits and Methods of Measurement GB 17625.1 The Limits for the Harmonic Current Emissions Caused by Low-voltage Electrical and Electronic Equipment (Equipment Input Current≤16A per Phase) GB 17625.2 Electromagnetic Compatibility (EMC) – Limits - Limitation of Voltage Changes, Voltage Fluctuations and Flicker in Public Low-voltage Supply Systems, for Equipment with Rated Current ≤16 A per Phase and Not Subject to Conditional Connection GB/T 17626.2 Electromagnetic Compatibility (EMC) - Testing and Measurement Techniques - Electrostatic Discharge Immunity Test GB/T 17626.3 Electromagnetic Compatibility - Testing and Measurement Techniques - Radiated Radio-frequency Electromagnetic Field Immunity Test GB/T 17626.4 Electromagnetic Compatibility - Testing and Measurement Techniques - Electrical Fast Transient/Burst Immunity Test GB/T 17626.5 Electromagnetic Compatibility - Testing and Measurement Techniques - Surge Immunity Test GB/T 17626.6 Electromagnetic Compatibility - Testing and Measurement Techniques - Immunity to Conducted Disturbances, Induced by Radio-frequency Fields GB/T 17626.8 Electromagnetic Compatibility - Testing and Measurement Techniques - Power Frequency Magnetic Field Immunity Test GB/T 17626.11 Electromagnetic Compatibility - Testing and Measurement Techniques - Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests YD/T 1312.1 Requirements and Measurement Methods of Electromagnetic Compatibility for Radio Communication Equipment - Part 1: Common Technical Requirements YD/T 1484-2006 Measurement Method for Radiated RF Power and Receiver Performance of Mobile Stations CISPR16-1-4 Specifications for Radio Disturbance and Immunity Measuring Apparatus ISO 7637-2 Road Vehicles - Electrical Disturbances from Conduction and Coupling - Part 2: Electrical Transient Conduction Along Supply Lines Only IEC 61000-4-29 Electromagnetic Compatibility - Testing and Measurement Techniques - Voltage Dips, Short Interruptions and Voltage Variations on D.C. Input Power Port Immunity Tests ITU-R SM.329 Spurious Emissions 3GPP2 C.S0033-0 Recommended Minimum Performance Standards for cdma2000 High Rate Packet Data Access Terminal 3GPP2 C.S0029 Test Application Specification for cdma2000 High Rate Packet Data Air Interface 3 Definitions and Abbreviations 3.1 Definitions For the purposes of this document, the following definitions apply. 3.1.1 data application ancillary ancillary equipment providing data access (sending and receiving) service between user equipment and server 3.1.2 forward CDMA channel
Foreword i 1 Scope 2 Normative References 3 Definitions and Abbreviations 4 Test Conditions 5 Performance Evaluation Method 6 Performance Criteria 7 Applicability 8 Measurement Methods and Limits of Disturbance 9 Immunity Test Method and Grade
Referred in YD/T 1597.1-2007:
*GB 9254-2008/XG1-2013 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
*GB/T 17618-2015 Information technology equipment―Immunity characteristics―Limits and methods of measurement
*GB 17625.1-2012 Electromagnetic compatibility—Limits—Limits for harmonic current emissions(equipment input current ≤16 A per phase)
*GB 17625.2-2007 Electromagnetic compatibility (EMC)—Limits—Limitation of voltage changes,voltage fluctuations and flicker in public low-voltage supply systems,for equipment with rated current ≤16 A pe
*GB/T 17626.2-l998
*GB/T 17626.3-2016 Electromagnetic compatibility- Testing and measurement techniques- Radiated,radio-frequency,electromagnetic field immunity test
*GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient/burst immunity test
*GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge immunity test
*GB/T 17626.6-2008 Electromagnetic compatibility - Testing and measurement techniques - Immunity to conducted disturbances induced by radio-frequency fields
*GB/T 17626.8-2006 Electromagnetic compatibility (EMC) - Part 8: Testing and measurement techniques - Power frequency magnetic field immunity test
*GB/T17626.11-1998
*YD/T 1312.1-2015
*YD/T 1484-2006 Measurement Method for Radiated RF Power and Receiver Performance of Mobile Stations
YD/T 1597.1-2007 is referred in:
*YD/T 1680-2013 Test method for 800MHz/2GHz cdma2000 digital cellular mobile telecommunication network equipment-High data rate packet data (Phase 2) - Access terminal
Code of China
Standard
YD/T 1597.1-2007  Requirements and Measurement Methods of Electromagnetic Compatibility for 2GHz cdma2000 Digital Cellular Mobile Communications System Part 1:User Equipment and Ancillary Equipment (English Version)
Standard No.YD/T 1597.1-2007
Statusvalid
LanguageEnglish
File FormatPDF
Word Count9000 words
Price(USD)270.0
Implemented on2007-5-16
Deliveryvia email in 1~3 business day
Detail of YD/T 1597.1-2007
Standard No.
YD/T 1597.1-2007
English Name
Requirements and Measurement Methods of Electromagnetic Compatibility for 2GHz cdma2000 Digital Cellular Mobile Communications System Part 1:User Equipment and Ancillary Equipment
Chinese Name
2GHz cdma2000数字蜂窝移动通信系统电磁兼容性要求和测量方法 第1部分:用户设备及其辅助设备
Chinese Classification
M37
Professional Classification
YD
ICS Classification
Issued by
Issued on
2007-5-16
Implemented on
2007-5-16
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
9000 words
Price(USD)
270.0
Keywords
YD/T 1597.1-2007, YD 1597.1-2007, YDT 1597.1-2007, YD/T1597.1-2007, YD/T 1597.1, YD/T1597.1, YD1597.1-2007, YD 1597.1, YD1597.1, YDT1597.1-2007, YDT 1597.1, YDT1597.1
Introduction of YD/T 1597.1-2007
1 Scope This part specifies the requirements, including limits, performance criteria and measuring methods, of electromagnetic compatibility (EMC) for user equipment and ancillary equipment of 2GHz cdma2000 digital cellular mobile communications system. This part is applicable to cdma2000 and cdma2000 HRPD user side equipment, including portable and on-board user equipment, for sending and receiving voice and/or data as well as those user equipment powered by AC supply and used in fixed position. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this part. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. GB 9254 Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement GB/T 17618 Information Technology Equipment - Immunity Characteristics - Limits and Methods of Measurement GB 17625.1 The Limits for the Harmonic Current Emissions Caused by Low-voltage Electrical and Electronic Equipment (Equipment Input Current≤16A per Phase) GB 17625.2 Electromagnetic Compatibility (EMC) – Limits - Limitation of Voltage Changes, Voltage Fluctuations and Flicker in Public Low-voltage Supply Systems, for Equipment with Rated Current ≤16 A per Phase and Not Subject to Conditional Connection GB/T 17626.2 Electromagnetic Compatibility (EMC) - Testing and Measurement Techniques - Electrostatic Discharge Immunity Test GB/T 17626.3 Electromagnetic Compatibility - Testing and Measurement Techniques - Radiated Radio-frequency Electromagnetic Field Immunity Test GB/T 17626.4 Electromagnetic Compatibility - Testing and Measurement Techniques - Electrical Fast Transient/Burst Immunity Test GB/T 17626.5 Electromagnetic Compatibility - Testing and Measurement Techniques - Surge Immunity Test GB/T 17626.6 Electromagnetic Compatibility - Testing and Measurement Techniques - Immunity to Conducted Disturbances, Induced by Radio-frequency Fields GB/T 17626.8 Electromagnetic Compatibility - Testing and Measurement Techniques - Power Frequency Magnetic Field Immunity Test GB/T 17626.11 Electromagnetic Compatibility - Testing and Measurement Techniques - Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests YD/T 1312.1 Requirements and Measurement Methods of Electromagnetic Compatibility for Radio Communication Equipment - Part 1: Common Technical Requirements YD/T 1484-2006 Measurement Method for Radiated RF Power and Receiver Performance of Mobile Stations CISPR16-1-4 Specifications for Radio Disturbance and Immunity Measuring Apparatus ISO 7637-2 Road Vehicles - Electrical Disturbances from Conduction and Coupling - Part 2: Electrical Transient Conduction Along Supply Lines Only IEC 61000-4-29 Electromagnetic Compatibility - Testing and Measurement Techniques - Voltage Dips, Short Interruptions and Voltage Variations on D.C. Input Power Port Immunity Tests ITU-R SM.329 Spurious Emissions 3GPP2 C.S0033-0 Recommended Minimum Performance Standards for cdma2000 High Rate Packet Data Access Terminal 3GPP2 C.S0029 Test Application Specification for cdma2000 High Rate Packet Data Air Interface 3 Definitions and Abbreviations 3.1 Definitions For the purposes of this document, the following definitions apply. 3.1.1 data application ancillary ancillary equipment providing data access (sending and receiving) service between user equipment and server 3.1.2 forward CDMA channel
Contents of YD/T 1597.1-2007
Foreword i 1 Scope 2 Normative References 3 Definitions and Abbreviations 4 Test Conditions 5 Performance Evaluation Method 6 Performance Criteria 7 Applicability 8 Measurement Methods and Limits of Disturbance 9 Immunity Test Method and Grade
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YD/T 1597.1-2007, YD 1597.1-2007, YDT 1597.1-2007, YD/T1597.1-2007, YD/T 1597.1, YD/T1597.1, YD1597.1-2007, YD 1597.1, YD1597.1, YDT1597.1-2007, YDT 1597.1, YDT1597.1