2025-12-15 10.2.82.121
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YD/T 5040-2005
YD/T 5040-2005   Design Specifications of Engineering for Telecommunication Power Supply Equipment Installation (excluding the Annexes) (English Version)
Standard No.: YD/T 5040-2005 Status:abolished remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 8000 words Translation Price(USD):200.0 remind me the price change

Email:

Implemented on:2006-10-1 Delivery: via email in 1 business day

→ → →

2017-05-12 ,,2006-10-1,1411374704128181262F10E1E83F0
Standard No.: YD/T 5040-2005
English Name: Design Specifications of Engineering for Telecommunication Power Supply Equipment Installation (excluding the Annexes)
Chinese Name: 通信电源设备安装工程设计规范
Chinese Classification: M41    Telecommunication power supply equipment
Professional Classification: YD    Professional Standard - Telecommunication
ICS Classification: 33.040.50 33.040.50    Lines, connections and circuits 33.040.50
Source Content Issued by: MIIT
Issued on: 2006-7-25
Implemented on: 2006-10-1
Status: abolished
Abolished on:2017-05-12
Superseding:YD 5040-1997 Design Standard for Telecommunications Power Supply Equipment Installation
YD 5046-1997 Temporary Design Specifications for Installation of Unattended Power Supply Equipments in Optical Fibre Cable Telecommunications Projects
Target Language: English
File Format: PDF
Word Count: 8000 words
Translation Price(USD): 200.0
Delivery: via email in 1 business day
1 General 1.0.1 This specification is applicable to the newly-built telecommunication power supply equipment installation. Extension and reconstruction engineering may refer to this specification. 1.0.2 Telecommunication power supply equipment installation design must implement the national technical policies, rationally utilize resource, and comply with the requirements of relevant national standards on aerial defense, shock resistance, firefighting and environmental protection etc. 1.0.3 Telecommunication power supply equipment installation design must take into account the convenience of installation, maintenance and use under the premise of ensuring power supply quality, and pay attention to the telecommunication security under special conditions such as wars or natural disasters etc. 1.0.4 The telecommunication equipments adopted in engineering design shall have the telecommunication equipment network access license issued by the Ministry of Information Industry. The equipments without telecommunication equipment network access license issued by the Ministry of Information Industry shall not be used in the engineering. The transmission and exchange equipments, as well as telecommunication power supplies etc., which are used in public telecommunication networks of the areas with the seismic fortification intensity of 7 in our country, shall have telecommunication equipment seismic performance testing quality certificates issued by the Ministry of Information Industry, and the telecommunication equipments without telecommunication equipment seismic performance testing quality certificate issued by the Ministry of Information Industry shall not be used in the engineering. 1.0.5 Short-term construction scale such as overall scheme and equipment selection shall be combined with long-term development plan, besides, multi-scheme technical and economical comparison shall be carried out according to factors such as construction and development conditions, economic effect, equipment service life and the possibility of extension and reconstruction, in order to select the scheme with high reliability, low construction cost and maintenance cost. 1.0.6 The design shall be practical, technologically advanced, economical and rational, safe and usable. The extension and reconstruction engineering shall take full consideration of the characteristics of the former telecommunication equipments, rationally use the former buildings, equipments and materials, and positively take innovative measures, in order to reach the objective of advanced, applicable and economical. 1.0.7 When this specification conflicts with relevant national standards and specifications, it shall be subject to national standards and specifications. When it is difficult to implement some provision of this specification, sufficient reasons shall be stated in the design and shall be examined and approved by competent department.
1 General 2 Mains Supply Classification and Power Supply 3 Power Supply System 3.1 AC Power Supply System 3.2 DC Power Supply System 3.3 Lightning Protection and Earthing System 3.4 Monitoring System 4 Equipment Configuration 4.1 Equipment Configuration Principles 4.2 Configuration of Emergency Generating Sets 4.3 Configuration of Storage Battery Set 4.4 Configuration of Conversion Equipment 5 Selection and Laying of Conductors 6 Machine Room and Equipment Layout 6.1 Machine Room Requirements 6.2 Equipment Layout
Code of China
Standard
YD/T 5040-2005  Design Specifications of Engineering for Telecommunication Power Supply Equipment Installation (excluding the Annexes) (English Version)
Standard No.YD/T 5040-2005
Statusabolished
LanguageEnglish
File FormatPDF
Word Count8000 words
Price(USD)200.0
Implemented on2006-10-1
Deliveryvia email in 1 business day
Detail of YD/T 5040-2005
Standard No.
YD/T 5040-2005
English Name
Design Specifications of Engineering for Telecommunication Power Supply Equipment Installation (excluding the Annexes)
Chinese Name
通信电源设备安装工程设计规范
Chinese Classification
M41
Professional Classification
YD
ICS Classification
Issued by
MIIT
Issued on
2006-7-25
Implemented on
2006-10-1
Status
abolished
Superseded by
Superseded on
Abolished on
2017-05-12
Superseding
YD 5040-1997 Design Standard for Telecommunications Power Supply Equipment Installation
YD 5046-1997 Temporary Design Specifications for Installation of Unattended Power Supply Equipments in Optical Fibre Cable Telecommunications Projects
Language
English
File Format
PDF
Word Count
8000 words
Price(USD)
200.0
Keywords
YD/T 5040-2005, YD 5040-2005, YDT 5040-2005, YD/T5040-2005, YD/T 5040, YD/T5040, YD5040-2005, YD 5040, YD5040, YDT5040-2005, YDT 5040, YDT5040
Introduction of YD/T 5040-2005
1 General 1.0.1 This specification is applicable to the newly-built telecommunication power supply equipment installation. Extension and reconstruction engineering may refer to this specification. 1.0.2 Telecommunication power supply equipment installation design must implement the national technical policies, rationally utilize resource, and comply with the requirements of relevant national standards on aerial defense, shock resistance, firefighting and environmental protection etc. 1.0.3 Telecommunication power supply equipment installation design must take into account the convenience of installation, maintenance and use under the premise of ensuring power supply quality, and pay attention to the telecommunication security under special conditions such as wars or natural disasters etc. 1.0.4 The telecommunication equipments adopted in engineering design shall have the telecommunication equipment network access license issued by the Ministry of Information Industry. The equipments without telecommunication equipment network access license issued by the Ministry of Information Industry shall not be used in the engineering. The transmission and exchange equipments, as well as telecommunication power supplies etc., which are used in public telecommunication networks of the areas with the seismic fortification intensity of 7 in our country, shall have telecommunication equipment seismic performance testing quality certificates issued by the Ministry of Information Industry, and the telecommunication equipments without telecommunication equipment seismic performance testing quality certificate issued by the Ministry of Information Industry shall not be used in the engineering. 1.0.5 Short-term construction scale such as overall scheme and equipment selection shall be combined with long-term development plan, besides, multi-scheme technical and economical comparison shall be carried out according to factors such as construction and development conditions, economic effect, equipment service life and the possibility of extension and reconstruction, in order to select the scheme with high reliability, low construction cost and maintenance cost. 1.0.6 The design shall be practical, technologically advanced, economical and rational, safe and usable. The extension and reconstruction engineering shall take full consideration of the characteristics of the former telecommunication equipments, rationally use the former buildings, equipments and materials, and positively take innovative measures, in order to reach the objective of advanced, applicable and economical. 1.0.7 When this specification conflicts with relevant national standards and specifications, it shall be subject to national standards and specifications. When it is difficult to implement some provision of this specification, sufficient reasons shall be stated in the design and shall be examined and approved by competent department.
Contents of YD/T 5040-2005
1 General 2 Mains Supply Classification and Power Supply 3 Power Supply System 3.1 AC Power Supply System 3.2 DC Power Supply System 3.3 Lightning Protection and Earthing System 3.4 Monitoring System 4 Equipment Configuration 4.1 Equipment Configuration Principles 4.2 Configuration of Emergency Generating Sets 4.3 Configuration of Storage Battery Set 4.4 Configuration of Conversion Equipment 5 Selection and Laying of Conductors 6 Machine Room and Equipment Layout 6.1 Machine Room Requirements 6.2 Equipment Layout
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YD/T 5040-2005, YD 5040-2005, YDT 5040-2005, YD/T5040-2005, YD/T 5040, YD/T5040, YD5040-2005, YD 5040, YD5040, YDT5040-2005, YDT 5040, YDT5040