2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY/T 0729.1-2009
YY/T 0729.1-2009   Test methods for boning properties of tissue adhesives—Part 1:Strength in lap-shear by tension loading (English Version)
Standard No.: YY/T 0729.1-2009 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 6000 words Translation Price(USD):180.0 remind me the price change

Email:

Implemented on:2010-12-1 Delivery: via email in 1 business day

→ → →

,,2010-12-1,14113767867253D358D397EC245B7
Standard No.: YY/T 0729.1-2009
English Name: Test methods for boning properties of tissue adhesives—Part 1:Strength in lap-shear by tension loading
Chinese Name: 组织粘合剂粘接性能试验方法 第1部分:搭接-剪切拉伸承载强度
Chinese Classification: C48    Medical sanitary products
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.120.20 11.120.20    Wound dressings and compresses 11.120.20
Source Content Issued by: AQSIQ; SAC
Issued on: 2009-06-16
Implemented on: 2010-12-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 6000 words
Translation Price(USD): 180.0
Delivery: via email in 1 business day
YY/T 0729.1-2009 Test methods for bonding properties of tissue adhesives - Part 1: Strength in lap-shear by tension loading 1 Scope The test methods specified in this part of YY/T 0729 are intended to provide a means for comparison of the adhesive strengths of tissue adhesives intended for use as surgical adhesives or sealants, or both, on soft tissue. With the appropriate choice of substrate, this part may also be used for purposes of quality control in the manufacture of tissue adhesive. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of YY/T 0729. For dated references, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. For undated references, the latest edition of the normative document applies. GB/T 16825.1 Verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Verification and calibration of the force-measuring system (GB/T 16825.1-2008, ISO 7500-1:2004, IDT) 3 Terms and definitions For the purposes of this part of YY/T 0729, the following terms and definitions apply. 3.1 tissue adhesive for the purposes of this part, tissue adhesive is defined as a compound or system intended for use in closing wounds (surgical or traumatic) or for sealing against leakage of body fluids 3.2 tissue sealant a surface coating with adequate adhesive strength to prevent leakage of body fluids   3.3 strength in lap-shear by tension loading average load per unit bonded area required to produce progressive separation of two adherends, under conditions designated in this part, expressed in megapascals (MPa) 4 Apparatus 4.1 Testing machine 4.1.1 Fixed member, a fixed or essentially stationary member carrying one grip. 4.1.2 Movable member, a movable member carrying a second grip. 4.1.3 Grips, for holding the test specimen between the fixed member and the movable member of the testing machine, can be either the fixed or self-aligning type. 4.1.3.1 Fixed grips are rigidly attached to the fixed and movable members of the testing machine. When this type of grip is used, extreme care should be taken to ensure that the test specimen is inserted and clamped so that the long axis of the test specimen coincides with the direction of pull through the centerline of the grip assembly.
Foreword I Introduction II 1 Scope 2 Normative references 3 Terms and definitions 4 Apparatus 5 Test substrate 6 Test specimen 7 Sample preparation 8 Test procedure 9 Calculations 10 Report Annex A (Normative) Rationale for test temperature used for comparative testing Annex B (Informative) Procedure for preparation of fresh porcine skin graft
Referred in YY/T 0729.1-2009:
*GB/T 16825.1-2022 Metallic materials—Calibration and verification of static uniaxial testing machines—Part1:Tension/compression testing machines—Calibration and verification of the force-measuring system
Code of China
Standard
YY/T 0729.1-2009  Test methods for boning properties of tissue adhesives—Part 1:Strength in lap-shear by tension loading (English Version)
Standard No.YY/T 0729.1-2009
Statusvalid
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)180.0
Implemented on2010-12-1
Deliveryvia email in 1 business day
Detail of YY/T 0729.1-2009
Standard No.
YY/T 0729.1-2009
English Name
Test methods for boning properties of tissue adhesives—Part 1:Strength in lap-shear by tension loading
Chinese Name
组织粘合剂粘接性能试验方法 第1部分:搭接-剪切拉伸承载强度
Chinese Classification
C48
Professional Classification
YY
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2009-06-16
Implemented on
2010-12-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
180.0
Keywords
YY/T 0729.1-2009, YY 0729.1-2009, YYT 0729.1-2009, YY/T0729.1-2009, YY/T 0729.1, YY/T0729.1, YY0729.1-2009, YY 0729.1, YY0729.1, YYT0729.1-2009, YYT 0729.1, YYT0729.1
Introduction of YY/T 0729.1-2009
YY/T 0729.1-2009 Test methods for bonding properties of tissue adhesives - Part 1: Strength in lap-shear by tension loading 1 Scope The test methods specified in this part of YY/T 0729 are intended to provide a means for comparison of the adhesive strengths of tissue adhesives intended for use as surgical adhesives or sealants, or both, on soft tissue. With the appropriate choice of substrate, this part may also be used for purposes of quality control in the manufacture of tissue adhesive. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of YY/T 0729. For dated references, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. For undated references, the latest edition of the normative document applies. GB/T 16825.1 Verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Verification and calibration of the force-measuring system (GB/T 16825.1-2008, ISO 7500-1:2004, IDT) 3 Terms and definitions For the purposes of this part of YY/T 0729, the following terms and definitions apply. 3.1 tissue adhesive for the purposes of this part, tissue adhesive is defined as a compound or system intended for use in closing wounds (surgical or traumatic) or for sealing against leakage of body fluids 3.2 tissue sealant a surface coating with adequate adhesive strength to prevent leakage of body fluids   3.3 strength in lap-shear by tension loading average load per unit bonded area required to produce progressive separation of two adherends, under conditions designated in this part, expressed in megapascals (MPa) 4 Apparatus 4.1 Testing machine 4.1.1 Fixed member, a fixed or essentially stationary member carrying one grip. 4.1.2 Movable member, a movable member carrying a second grip. 4.1.3 Grips, for holding the test specimen between the fixed member and the movable member of the testing machine, can be either the fixed or self-aligning type. 4.1.3.1 Fixed grips are rigidly attached to the fixed and movable members of the testing machine. When this type of grip is used, extreme care should be taken to ensure that the test specimen is inserted and clamped so that the long axis of the test specimen coincides with the direction of pull through the centerline of the grip assembly.
Contents of YY/T 0729.1-2009
Foreword I Introduction II 1 Scope 2 Normative references 3 Terms and definitions 4 Apparatus 5 Test substrate 6 Test specimen 7 Sample preparation 8 Test procedure 9 Calculations 10 Report Annex A (Normative) Rationale for test temperature used for comparative testing Annex B (Informative) Procedure for preparation of fresh porcine skin graft
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YY/T 0729.1-2009, YY 0729.1-2009, YYT 0729.1-2009, YY/T0729.1-2009, YY/T 0729.1, YY/T0729.1, YY0729.1-2009, YY 0729.1, YY0729.1, YYT0729.1-2009, YYT 0729.1, YYT0729.1