2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY/T 0851-2023
YY/T 0851-2023   Medical thrombosis prophylaxis hosiery (English Version)
Standard No.: YY/T 0851-2023 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 13500 words Translation Price(USD):405.0 remind me the price change

Email:

Implemented on:2024-9-15 Delivery: via email in 1 business day

→ → →

,,2024-9-15,322600083BB1BA8F1694589393718
Standard No.: YY/T 0851-2023
English Name: Medical thrombosis prophylaxis hosiery
Chinese Name: 医用防血栓袜
Chinese Classification: C31    General and microsurgical devices
Professional Classification: YY    Professional Standard - Pharmaceutics
Source Content Issued by: National Medical Products Adminstration
Issued on: 2023-09-05
Implemented on: 2024-9-15
Status: valid
Superseding:YY/T 0851-2011 Medical thrombosis prophylaxis hosiery
Target Language: English
File Format: PDF
Word Count: 13500 words
Translation Price(USD): 405.0
Delivery: via email in 1 business day
YY/T 0851-2023 Medical thrombosis prophylaxis hosiery 1 Scope This document specifies requirements and gives test methods for medical thrombosis prophylaxis hosiery knitted from threads made of natural fibres or synthetic fibres. This document is applicable to thrombosis prophylaxis hosiery which is used as a medical device for the prevention of venous thrombosis. This document is not applicable to custom made hosiery. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6529-2008 Textiles - Standard atmospheres for conditioning and testing GB/T 8629-2017 Textiles - Domestic washing and drying procedures for textile testing GB/T 13634 Metallic materials - Calibration of force-proving instruments used for the verification of uniaxial testing machines YY/T 0466.1 Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: general requirements 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 compression pressure exerted on the leg by the thrombosis prophylaxis hosiery (3.8) 3.2 durability ability of thrombosis prophylaxis hosiery (3.8) to retain its designated compression 3.3 extensibility maximum degree, expressed as a percentage of the unloaded size of the thrombosis prophylaxis hosiery (3.8), in which the thrombosis prophylaxis hosiery (3.8) can be stretched in the transverse (circumferential) or in the longitudinal direction (lengthwise direction of the leg) under the test procedure specified in this document 3.4 practical elongation elongation of hosiery in the circumferential direction with the hosiery on the leg, expressed as a percentage of the difference between the designated and non-stretched girths to the non-stretched girth 3.5 pressure profile representation of the compression (3.1) exerted by the thrombosis prophylaxis hosiery (3.8) along the leg 3.6 residual pressure compression (3.1) at a certain point expressed as a percentage of the compression (3.1) at the ankle 3.7 standard size hosiery thrombosis prophylaxis hosiery (3.8) manufactured in the types and sizes specified in this document 3.8 medical thrombosis prophylaxis hosiery hosiery which when worn on the leg exerts graduated compression on the leg surface and is intended to reduce the incidence of venous thrombosis Note: It is abbreviated in this document to “thrombosis prophylaxis hosiery”. 4 Compression The compression of the thrombosis prophylaxis hosiery on the ankle shall be labeled in one of the following two ways: Where it is labeled by range, the compression shall range from 17.5 hPa to 24 hPa (13 mmHg to 18 mmHg); Where it is labeled by nominal value, the tolerance shall not exceed ±4.0 hPa (3 mmHg). The compression shall be measured in accordance with Annex A.
Foreword i Introduction iii 1 Scope 2 Normative references 3 Terms and definitions 4 Compression 5 Nominal dimensions and standard sizes 6 Heel 7 Ease of examination 8 Seams 9 Edges 10 Achievement of pressure profile 11 Mechanical properties 12 Packaging 13 Marking and instructions for use Annex A (Normative) Method for testing compressive properties of thrombosis prophylaxis hosiery Annex B (Normative) Method of determination of extensibility of thrombosis prophylaxis hosiery Annex C (Normative) Method of determination of durability of thrombosis prophylaxis hosiery Bibliography
Referred in YY/T 0851-2023:
*GB/T 6529-2008 Textiles—Standard atmospheres for conditioning and testing
*GB/T 8629-2017 Textiles―Domestic washing and drying procedures for textile testing
*GB/T 13634-2019 Metallic materials—Calibration of force-proving instruments used for the verification of uniaxial testing machines
*YY/T 0466.1-2023 Medical devices―Symbols to be used with information to be supplied by the manufacturer―Part 1:General requirements
Code of China
Standard
YY/T 0851-2023  Medical thrombosis prophylaxis hosiery (English Version)
Standard No.YY/T 0851-2023
Statusvalid
LanguageEnglish
File FormatPDF
Word Count13500 words
Price(USD)405.0
Implemented on2024-9-15
Deliveryvia email in 1 business day
Detail of YY/T 0851-2023
Standard No.
YY/T 0851-2023
English Name
Medical thrombosis prophylaxis hosiery
Chinese Name
医用防血栓袜
Chinese Classification
C31
Professional Classification
YY
ICS Classification
Issued by
National Medical Products Adminstration
Issued on
2023-09-05
Implemented on
2024-9-15
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
YY/T 0851-2011 Medical thrombosis prophylaxis hosiery
Language
English
File Format
PDF
Word Count
13500 words
Price(USD)
405.0
Keywords
YY/T 0851-2023, YY 0851-2023, YYT 0851-2023, YY/T0851-2023, YY/T 0851, YY/T0851, YY0851-2023, YY 0851, YY0851, YYT0851-2023, YYT 0851, YYT0851
Introduction of YY/T 0851-2023
YY/T 0851-2023 Medical thrombosis prophylaxis hosiery 1 Scope This document specifies requirements and gives test methods for medical thrombosis prophylaxis hosiery knitted from threads made of natural fibres or synthetic fibres. This document is applicable to thrombosis prophylaxis hosiery which is used as a medical device for the prevention of venous thrombosis. This document is not applicable to custom made hosiery. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6529-2008 Textiles - Standard atmospheres for conditioning and testing GB/T 8629-2017 Textiles - Domestic washing and drying procedures for textile testing GB/T 13634 Metallic materials - Calibration of force-proving instruments used for the verification of uniaxial testing machines YY/T 0466.1 Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: general requirements 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 compression pressure exerted on the leg by the thrombosis prophylaxis hosiery (3.8) 3.2 durability ability of thrombosis prophylaxis hosiery (3.8) to retain its designated compression 3.3 extensibility maximum degree, expressed as a percentage of the unloaded size of the thrombosis prophylaxis hosiery (3.8), in which the thrombosis prophylaxis hosiery (3.8) can be stretched in the transverse (circumferential) or in the longitudinal direction (lengthwise direction of the leg) under the test procedure specified in this document 3.4 practical elongation elongation of hosiery in the circumferential direction with the hosiery on the leg, expressed as a percentage of the difference between the designated and non-stretched girths to the non-stretched girth 3.5 pressure profile representation of the compression (3.1) exerted by the thrombosis prophylaxis hosiery (3.8) along the leg 3.6 residual pressure compression (3.1) at a certain point expressed as a percentage of the compression (3.1) at the ankle 3.7 standard size hosiery thrombosis prophylaxis hosiery (3.8) manufactured in the types and sizes specified in this document 3.8 medical thrombosis prophylaxis hosiery hosiery which when worn on the leg exerts graduated compression on the leg surface and is intended to reduce the incidence of venous thrombosis Note: It is abbreviated in this document to “thrombosis prophylaxis hosiery”. 4 Compression The compression of the thrombosis prophylaxis hosiery on the ankle shall be labeled in one of the following two ways: Where it is labeled by range, the compression shall range from 17.5 hPa to 24 hPa (13 mmHg to 18 mmHg); Where it is labeled by nominal value, the tolerance shall not exceed ±4.0 hPa (3 mmHg). The compression shall be measured in accordance with Annex A.
Contents of YY/T 0851-2023
Foreword i Introduction iii 1 Scope 2 Normative references 3 Terms and definitions 4 Compression 5 Nominal dimensions and standard sizes 6 Heel 7 Ease of examination 8 Seams 9 Edges 10 Achievement of pressure profile 11 Mechanical properties 12 Packaging 13 Marking and instructions for use Annex A (Normative) Method for testing compressive properties of thrombosis prophylaxis hosiery Annex B (Normative) Method of determination of extensibility of thrombosis prophylaxis hosiery Annex C (Normative) Method of determination of durability of thrombosis prophylaxis hosiery Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YY/T 0851-2023, YY 0851-2023, YYT 0851-2023, YY/T0851-2023, YY/T 0851, YY/T0851, YY0851-2023, YY 0851, YY0851, YYT0851-2023, YYT 0851, YYT0851