2026-7-26 10.2.208.129
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY/T 0916.7-2024
YY/T 0916.7-2024   Small-bore connectors for liquids and gases in healthcare applications—Part 7:Connectors for intravascular or hypodermic applications (English)
Standard No.: YY/T 0916.7-2024 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 32760 words Translation Price(USD):1310.4 remind me the price change

Email:

Implemented on:2026-7-20 Delivery: via email in 1~8 business day

→ → →

,,2026-7-20,AF5DB6BED8D33BEC1721137484230
Standard No.: YY/T 0916.7-2024
English Name: Small-bore connectors for liquids and gases in healthcare applications—Part 7:Connectors for intravascular or hypodermic applications
Chinese Name: 医用液体和气体用小孔径连接件 第7部分:血管内或皮下应用连接件
Chinese Classification: C30    Medical apparatus and devices in general
Professional Classification: YY    Professional Standard - Pharmaceutics
Source Content Issued by: National Medical Products Adminstration
Issued on: 2024-07-08
Implemented on: 2026-7-20
Status: valid
Target Language: English
File Format: PDF
Word Count: 32760 words
Translation Price(USD): 1310.4
Delivery: via email in 1~8 business day
本文件规定了小孔径连接件的尺寸,以及设计和功能特性的要求,这些小孔径连接件预期用于医疗器械和附件的血管内应用连接或皮下应用的皮下注射连接。本文件未规定使用这些连接件的医疗器械或附件的要求。这些要求在特定医疗器械或附件的专用文件中给出。本文件未规定下列其他文件中规定的小孔径连接件的要求:血液透析器、血液透析滤过器和血液滤过器血室接口(ISO 8637和ISO 8638有关血室接口的适用部分);血液透析、血液透析滤过和血液滤过设备连接件(ISO 8637);输液系统的瓶塞穿刺连接件(ISO 8536-4)。
Foreword i Introduction ii 1 Scope 2 Normative references 3 Terms and definitions 4 General requirements 4.1 General requirements for Luer connector 4.2 Type tests 5 Dimensional requirements for Luer connectors 6 Performance requirements 6.1 Fluid leakage 6.1.1 Fluid leakage requirement 6.1.2 Leakage by pressure decay 6.1.3 Positive pressure liquid leakage 6.2 Sub-atmospheric pressure air leakage 6.3 Stress cracking 6.4 Resistance to separation from axial load 6.5 Resistance to separation from unscrewing 6.6 Resistance to overriding Annex A (Informative) Rationale and guidance for the contents of this document adopted from ISO 80369-7:2021, Annex A A.1 General guidance A.2 Rationale for particular clauses and subclauses Annex B (Normative) Luer connectors Annex C (Normative) Reference connectors C.1 General requirements for reference connectors C.2 Reference connectors Annex D (Informative) Assessment of medical devices and their attributes with connections within this application Annex E (Informative) Summary of the usability requirements for Luer connectors for intravascular or hypodermic applications E.1 User profile E.2 Use scenarios E.3 Use environments E.4 Other attributes E.5 Generic user needs Annex F (Informative) Summary of Luer connector design requirements for intravascular or hypodermic applications Annex G (Informative) Summary of assessment of the design of the Luer connector for intravascular or hypodermic applications G.1 General G.2 Summary of the engineering analysis of the design G.3 Summary of the design verification G.4 Summary of the design validation G.5 Summary of the design review Annex H (Informative) Reference to the essential principles Annex I (Informative) Reference to the general safety and performance requirements Annex J (Informative) Terminology - Alphabetized index of defined terms Bibliography Figure A.1 Lug corners that can interfere Figure A.2 Area of potential interference Figure B.1 Male Luer slip connector (L1) Figure B.2 Female Luer slip connector (L1) Figure B.3 Male Luer lock connector (L2), with fixed collar Figure B.4 Male Luer lock connector (L2), with rotatable collar Figure B.5 Female Luer lock connector (L2) Figure B.6 Female Luer lock connector with lugs at right angle to axis (L2), variant A Figure B.7 Female Luer lock connector with lugs at right angle to axis (L2), variant B Figure B.8 Female Luer lock connector with lugs at right angle to axis (L2), variant C Figure C.1 Female reference Luer lock connector for testing male Luer connectors for leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics Figure C.2 Male reference Luer slip connector for testing female Luer connectors for leakage, separation from axial load, stress cracking and non-interconnectable characteristics Figure C.3 Female reference Luer lock connector for testing male Luer lock connector for separation from axial load and resistance to overriding Figure C.4 Male reference Luer lock connector for testing female Luer connectors for leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics Figure C.5 Female reference Luer slip connector for testing male Luer connectors for leakage, separation from axial load, stress cracking and non-interconnectable characteristics Figure C.6 Male reference connector for testing female Luer lock connector for separation from axial load and resistance to overriding Figure G.1 Illustration Luer connector male to N1 male misconnection Table B.1 Male Luer slip connector dimensions (L1) Table B.2 Female Luer slip connector dimensions (L1) Table B.3 Male Luer lock connector, with fixed collar dimensions (L2) Table B.4 Male Luer lock connector (L2), with rotatable collar dimensions Table B.5 Female Luer lock connector dimensions (L2) Table B.6 Female Luer lock connector dimensions (L2), variant A Table B.7 Female Luer lock connector dimensions (L2), variant B Table B.8 Female Luer lock connector dimensions (L2), variant C Table D.1 Examples of medical devices with connections within this application and their attributes Table E.1 User profile Table E.2 Use scenarios Table F.1 Luer connector specific design requirements for intravascular or hypodermic applications Table G.1 Summary of possible misconnection from CAD analysis Table H.1 Correspondence between this document and the essential principles Table I.1 Correspondence between this document and the general safety and performance requirements Table I.2 Correspondence between this document and relevant essential health and safety requirements from Directive 2006/42/EC on machinery
Referred in YY/T 0916.7-2024:
*YY/T 0916.1-2021 Small-bore connectors for liquids and gases in healthcare applications―Part 1:General requirements
*YY/T 0916.6-2022 Small-bore connectors for liquids and gases in healthcare applications-Part 6:Connectors for neuraxial applications
*YY/T 0916.20-2019 Small-bore connectors for liquids and gases in healthcare applications―Part 20:Common test methods
YY/T 0916.7-2024 is referred in:
*YY 0267-2025 Extracorporeal systems for blood purification Extracorporeal blood and fluid circuits for haemodialysers, haemodiafilters, haemofilters and haemoconcentrators
Code of China
Standard
YY/T 0916.7-2024  Small-bore connectors for liquids and gases in healthcare applications—Part 7:Connectors for intravascular or hypodermic applications (English)
Standard No.YY/T 0916.7-2024
Statusvalid
LanguageEnglish
File FormatPDF
Word Count32760 words
Translation Price(USD)1310.4
Implemented on2026-7-20
Deliveryvia email in 1~8 business day
Detail of YY/T 0916.7-2024
Standard No.
YY/T 0916.7-2024
English Name
Small-bore connectors for liquids and gases in healthcare applications—Part 7:Connectors for intravascular or hypodermic applications
Chinese Name
医用液体和气体用小孔径连接件 第7部分:血管内或皮下应用连接件
Chinese Classification
C30
Professional Classification
YY
ICS Classification
Issued by
National Medical Products Adminstration
Issued on
2024-07-08
Implemented on
2026-7-20
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
32760 words
Translation Price(USD)
1310.4
Keywords
YY/T 0916.7-2024, YY 0916.7-2024, YYT 0916.7-2024, YY/T0916.7-2024, YY/T 0916.7, YY/T0916.7, YY0916.7-2024, YY 0916.7, YY0916.7, YYT0916.7-2024, YYT 0916.7, YYT0916.7
Introduction of YY/T 0916.7-2024
本文件规定了小孔径连接件的尺寸,以及设计和功能特性的要求,这些小孔径连接件预期用于医疗器械和附件的血管内应用连接或皮下应用的皮下注射连接。本文件未规定使用这些连接件的医疗器械或附件的要求。这些要求在特定医疗器械或附件的专用文件中给出。本文件未规定下列其他文件中规定的小孔径连接件的要求:血液透析器、血液透析滤过器和血液滤过器血室接口(ISO 8637和ISO 8638有关血室接口的适用部分);血液透析、血液透析滤过和血液滤过设备连接件(ISO 8637);输液系统的瓶塞穿刺连接件(ISO 8536-4)。
Contents of YY/T 0916.7-2024
Foreword i Introduction ii 1 Scope 2 Normative references 3 Terms and definitions 4 General requirements 4.1 General requirements for Luer connector 4.2 Type tests 5 Dimensional requirements for Luer connectors 6 Performance requirements 6.1 Fluid leakage 6.1.1 Fluid leakage requirement 6.1.2 Leakage by pressure decay 6.1.3 Positive pressure liquid leakage 6.2 Sub-atmospheric pressure air leakage 6.3 Stress cracking 6.4 Resistance to separation from axial load 6.5 Resistance to separation from unscrewing 6.6 Resistance to overriding Annex A (Informative) Rationale and guidance for the contents of this document adopted from ISO 80369-7:2021, Annex A A.1 General guidance A.2 Rationale for particular clauses and subclauses Annex B (Normative) Luer connectors Annex C (Normative) Reference connectors C.1 General requirements for reference connectors C.2 Reference connectors Annex D (Informative) Assessment of medical devices and their attributes with connections within this application Annex E (Informative) Summary of the usability requirements for Luer connectors for intravascular or hypodermic applications E.1 User profile E.2 Use scenarios E.3 Use environments E.4 Other attributes E.5 Generic user needs Annex F (Informative) Summary of Luer connector design requirements for intravascular or hypodermic applications Annex G (Informative) Summary of assessment of the design of the Luer connector for intravascular or hypodermic applications G.1 General G.2 Summary of the engineering analysis of the design G.3 Summary of the design verification G.4 Summary of the design validation G.5 Summary of the design review Annex H (Informative) Reference to the essential principles Annex I (Informative) Reference to the general safety and performance requirements Annex J (Informative) Terminology - Alphabetized index of defined terms Bibliography Figure A.1 Lug corners that can interfere Figure A.2 Area of potential interference Figure B.1 Male Luer slip connector (L1) Figure B.2 Female Luer slip connector (L1) Figure B.3 Male Luer lock connector (L2), with fixed collar Figure B.4 Male Luer lock connector (L2), with rotatable collar Figure B.5 Female Luer lock connector (L2) Figure B.6 Female Luer lock connector with lugs at right angle to axis (L2), variant A Figure B.7 Female Luer lock connector with lugs at right angle to axis (L2), variant B Figure B.8 Female Luer lock connector with lugs at right angle to axis (L2), variant C Figure C.1 Female reference Luer lock connector for testing male Luer connectors for leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics Figure C.2 Male reference Luer slip connector for testing female Luer connectors for leakage, separation from axial load, stress cracking and non-interconnectable characteristics Figure C.3 Female reference Luer lock connector for testing male Luer lock connector for separation from axial load and resistance to overriding Figure C.4 Male reference Luer lock connector for testing female Luer connectors for leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics Figure C.5 Female reference Luer slip connector for testing male Luer connectors for leakage, separation from axial load, stress cracking and non-interconnectable characteristics Figure C.6 Male reference connector for testing female Luer lock connector for separation from axial load and resistance to overriding Figure G.1 Illustration Luer connector male to N1 male misconnection Table B.1 Male Luer slip connector dimensions (L1) Table B.2 Female Luer slip connector dimensions (L1) Table B.3 Male Luer lock connector, with fixed collar dimensions (L2) Table B.4 Male Luer lock connector (L2), with rotatable collar dimensions Table B.5 Female Luer lock connector dimensions (L2) Table B.6 Female Luer lock connector dimensions (L2), variant A Table B.7 Female Luer lock connector dimensions (L2), variant B Table B.8 Female Luer lock connector dimensions (L2), variant C Table D.1 Examples of medical devices with connections within this application and their attributes Table E.1 User profile Table E.2 Use scenarios Table F.1 Luer connector specific design requirements for intravascular or hypodermic applications Table G.1 Summary of possible misconnection from CAD analysis Table H.1 Correspondence between this document and the essential principles Table I.1 Correspondence between this document and the general safety and performance requirements Table I.2 Correspondence between this document and relevant essential health and safety requirements from Directive 2006/42/EC on machinery
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 3680948734
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YY/T 0916.7-2024, YY 0916.7-2024, YYT 0916.7-2024, YY/T0916.7-2024, YY/T 0916.7, YY/T0916.7, YY0916.7-2024, YY 0916.7, YY0916.7, YYT0916.7-2024, YYT 0916.7, YYT0916.7