2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY/T 1556-2017
YY/T 1556-2017   Test methods for particle contamination of infusion, transfusion and injection equipments for medical use (English Version)
Standard No.: YY/T 1556-2017 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5500 words Translation Price(USD):165.0 remind me the price change

Email:

Implemented on:2018-4-1 Delivery: via email in 1 business day

→ → →

,,2018-4-1,95A5985012A893AD1491478296237
Standard No.: YY/T 1556-2017
English Name: Test methods for particle contamination of infusion, transfusion and injection equipments for medical use
Chinese Name: 医用输液、输血、注射器具微粒污染检验方法
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.040.20 11.040.20    Transfusion, infusion and injection equipment 11.040.20
Source Content Issued by: China Food and Drug Adminstration
Issued on: 2017-03-28
Implemented on: 2018-4-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 5500 words
Translation Price(USD): 165.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights. This standard was proposed by the China Food and Drug Administration. This standard is under the jurisdiction of the SAC/TC 106 National Technical Committee on Medical Syringes of Standardization Administration of China. Introduction During infusion, transfusion and injection, some insoluble particles enter the human body, causing harm to patients. This standard provides a general test method for particle contamination test of infusion and injection equipments. There are three kinds of fluids for washing to choose from in this standard: purified water, isopropyl alcohol and prepared Tween-80 solution with a certain concentration. The purified water is suitable for non-silicified test samples, and isopropyl alcohol and Tween-80 solution are suitable for silicified test samples. However, the particle counter method is not applicable to Tween-80 solution as it is easy to bubble in the process of shaking or stirring. It is suggested to take necessary protection in case of using isopropyl alcohol as it is volatile and toxic. The product standards shall prevail comparing with method standards in case of selecting the test method. Test methods for particle contamination of infusion, transfusion and injection equipments for medical use 1 Scope This standard specifies the test methods for particle contamination of intravenous infusion, transfusion and injection equipments. This standard is applicable to tests for particle contamination of intravenous infusion and injection equipments. Other products may refer to this standard for test methods for particle contamination. This standard is not applicable to injection devices with a nominal capacity of 1mL or less for intramuscular injection. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods (ISO 3696: 1987, MOD) GB/T 25915.1-2010 Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness (ISO 14644-1: 1999, IDT) 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply. 3.1 fluids for washing fluids that have not contacted with the test samples and are used to elute the particles contained in the test samples   3.2 fluids after washing fluids in which the particles contained in the samples have been eluted into the fluid for washing after the fluid for washing comes into contact with the test samples 3.3 blank test test conducted for particles contained in fluids for washing, glass containers and test instruments 3.4 tubings flexible tubes used outside the human body, whose inner surfaces are in direct or indirect contact with human blood, such as infusion and transfusion equipments 3.5 intravascular catheters flexible tubes inserted into human blood vessels, such as central venous catheter and angiographic catheter 3.6 injection devices apparatus at least composed of piston and barrel, such as hypodermic syringe and high-pressure angiographic syringe 3.7 containers apparatus with large internal cavity, which is in direct or indirect contact with human blood, such as liquid storage bag/bottle and blood separation cup Note: Containers with tubes shall be regarded as containers. 3.8 small entries apparatus whose outer surface is in direct or indirect contact with human blood during use, such as syringe piston and guide wire 3.9 piercing devices devices that provides infusion and injection channels for human tissue piercing, such as intravenous infusion needles and intravenous remaining needles 3.10 die lumens devices with small inner cavity, which are in direct or indirect contact with human blood, such as heparin cap and three-way valve 3.11 unit washing fluid fluid after washing prepared from single product with a specified method Note: The particle contamination of single product can be independently judged based on the test result obtained from the unit washing fluid. 3.12 collected fluid fluid after washing obtained with a specified method by gathering together the fluids after washing prepared from multiple products Note: The collected fluid is not applicable to independent judgment on particle contamination of one product, but applicable to overall judgment on particle contamination of multiple products.   4 General 4.1 The test shall be carried out under a laminar flow cleaning condition [the clean bench meeting the requirements for ISO Class 5 (100 classes) in GB/T 25915.1-2010]. The test personnel shall wear appropriate clean clothes and gloves, and the test instruments and other required articles shall be clean and free of particles, so as to ensure that external contamination will not be introduced in the test environment and thus affecting the test results. 4.2 Prior to test, the fluid for washing shall be inspected for blank test in the same way as the fluid after washing in the corresponding test. For the purpose of the blank test, the requirement that the particle contamination of 500mL of the fluid for washing is not more than 9 shall be met. If the fluid for washing required for the test is of other volumes, its contamination index shall be converted according to the multiple relationship between the volume of the fluid for washing and 500mL. 4.3 For fluids after washing in each test, the particles shall be classified and counted according to those specified in Table 1, and the contamination index shall be calculated according to clause 12. 4.4 The particle counter used shall be calibrated at least once every year. 5 Size classification and evaluation coefficients of particles See Table 1 for the size classification and corresponding evaluation coefficient of particles in the fluids for washing and fluids after washing. Table 1 Size classification and evaluation coefficients of particles causing contamination Parameter Size classification Particle size/μm 25~50 (Category I) 51~100 (Category II) >100 (Category III) Number of particles in the sample na1 na2 na3 Number of particles in blank test nb1 nb2 nb3 Evaluation coefficient 0.1 0.2 5 6 Principle Select the appropriate fluids for washing to wash the test pieces with the specified method, and use the appropriate counting method to classify and count the particles in the fluids for washing (3.2).
Foreword i Introduction ii 1 Scope 2 Normative references 3 Terms and definitions 4 General 5 Size classification and evaluation coefficients of particles 6 Principle 7 Apparatus and materials 8 Selection of fluids for washing 9 Selection of counting methods 10 Preparation of fluids after washing 11 Particle counting methods 12 Expression of results 13 Test report
Referred in YY/T 1556-2017:
*GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods
*GB/T 25915.1-2010 Cleanrooms and associated controlled environments—Part 1:Classification of air cleanliness
*YY/T 0654-2017 Automatic chemistry analyzer
*GB 50227-2017 Code for design of installation of shunt capacitors
*QB/T 2658-2017 Lavatory for sanitary fittings
*QB/T 2551-2008 Technological condition of cast iron dryers used in paper machinery
*QB/T 2584-2007 Shower room
*GB 31638-2016 National food safety standard - Casein
*GB/T 18241.1-2014 Rubber lining―Part 1:Anticorrosion lining for equipment
*GB/T 18209.2-2010 Electrical safety of machinery―Indication marking and actuation―Part 2:Requirements for marking
*GB/T 16895.2-2005 Electrical installations of buildings--Part 4-42:Protection for safety--Protection against--Thermal effects
*GB/T 10827.5-2013 Industrial trucks―Safety requirements and verification―Part 5:Pedestrian-propelled trucks
*GB/T 12668.3-2012 Adjustable speed electrical power drive systems―Part 3:EMC requirements and specific test methods
*GB/T 15574-2016 Steel products classification
YY/T 1556-2017 is referred in:
*GB/T 19335-2022 Blood flow products for single use-General specification
*GB 5009.138-2017 Food safety national standard -- Determination of nickel in food
*GB 5009.93-2017 Food safety national standard -- Determination of selenium in food
*GB 5009.91-2017 National Food Safety Standard -- Determination of potassium and sodium in food
*GB 5009.13-2017 National food safety standard -- Determination of copper in foods
*GB 5009.12-2017 Food safety national standard -- Determination of lead in food
*GB 2761-2017 Food safety national standard -- Fungi toxins in food
*JG/T 510-2016 Textile wallcovering
*HJ 828-2017 Water quality-Determination of the chemical oxygen demand-Dichromate method
*GB/T 26369-2010 Hygienic standard for quaternary ammonium disinfectant
*GB/T 15766.1-2008 Lamps for road vehicles - Dimensional electrical and luminous requirements
*YY/T 1898-2024 Intravascular catheter and guidewire -Testing method for fastness of the coating
Code of China
Standard
YY/T 1556-2017  Test methods for particle contamination of infusion, transfusion and injection equipments for medical use (English Version)
Standard No.YY/T 1556-2017
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)165.0
Implemented on2018-4-1
Deliveryvia email in 1 business day
Detail of YY/T 1556-2017
Standard No.
YY/T 1556-2017
English Name
Test methods for particle contamination of infusion, transfusion and injection equipments for medical use
Chinese Name
医用输液、输血、注射器具微粒污染检验方法
Chinese Classification
Professional Classification
YY
ICS Classification
Issued by
China Food and Drug Adminstration
Issued on
2017-03-28
Implemented on
2018-4-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
165.0
Keywords
YY/T 1556-2017, YY 1556-2017, YYT 1556-2017, YY/T1556-2017, YY/T 1556, YY/T1556, YY1556-2017, YY 1556, YY1556, YYT1556-2017, YYT 1556, YYT1556
Introduction of YY/T 1556-2017
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights. This standard was proposed by the China Food and Drug Administration. This standard is under the jurisdiction of the SAC/TC 106 National Technical Committee on Medical Syringes of Standardization Administration of China. Introduction During infusion, transfusion and injection, some insoluble particles enter the human body, causing harm to patients. This standard provides a general test method for particle contamination test of infusion and injection equipments. There are three kinds of fluids for washing to choose from in this standard: purified water, isopropyl alcohol and prepared Tween-80 solution with a certain concentration. The purified water is suitable for non-silicified test samples, and isopropyl alcohol and Tween-80 solution are suitable for silicified test samples. However, the particle counter method is not applicable to Tween-80 solution as it is easy to bubble in the process of shaking or stirring. It is suggested to take necessary protection in case of using isopropyl alcohol as it is volatile and toxic. The product standards shall prevail comparing with method standards in case of selecting the test method. Test methods for particle contamination of infusion, transfusion and injection equipments for medical use 1 Scope This standard specifies the test methods for particle contamination of intravenous infusion, transfusion and injection equipments. This standard is applicable to tests for particle contamination of intravenous infusion and injection equipments. Other products may refer to this standard for test methods for particle contamination. This standard is not applicable to injection devices with a nominal capacity of 1mL or less for intramuscular injection. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods (ISO 3696: 1987, MOD) GB/T 25915.1-2010 Cleanrooms and associated controlled environments - Part 1: Classification of air cleanliness (ISO 14644-1: 1999, IDT) 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply. 3.1 fluids for washing fluids that have not contacted with the test samples and are used to elute the particles contained in the test samples   3.2 fluids after washing fluids in which the particles contained in the samples have been eluted into the fluid for washing after the fluid for washing comes into contact with the test samples 3.3 blank test test conducted for particles contained in fluids for washing, glass containers and test instruments 3.4 tubings flexible tubes used outside the human body, whose inner surfaces are in direct or indirect contact with human blood, such as infusion and transfusion equipments 3.5 intravascular catheters flexible tubes inserted into human blood vessels, such as central venous catheter and angiographic catheter 3.6 injection devices apparatus at least composed of piston and barrel, such as hypodermic syringe and high-pressure angiographic syringe 3.7 containers apparatus with large internal cavity, which is in direct or indirect contact with human blood, such as liquid storage bag/bottle and blood separation cup Note: Containers with tubes shall be regarded as containers. 3.8 small entries apparatus whose outer surface is in direct or indirect contact with human blood during use, such as syringe piston and guide wire 3.9 piercing devices devices that provides infusion and injection channels for human tissue piercing, such as intravenous infusion needles and intravenous remaining needles 3.10 die lumens devices with small inner cavity, which are in direct or indirect contact with human blood, such as heparin cap and three-way valve 3.11 unit washing fluid fluid after washing prepared from single product with a specified method Note: The particle contamination of single product can be independently judged based on the test result obtained from the unit washing fluid. 3.12 collected fluid fluid after washing obtained with a specified method by gathering together the fluids after washing prepared from multiple products Note: The collected fluid is not applicable to independent judgment on particle contamination of one product, but applicable to overall judgment on particle contamination of multiple products.   4 General 4.1 The test shall be carried out under a laminar flow cleaning condition [the clean bench meeting the requirements for ISO Class 5 (100 classes) in GB/T 25915.1-2010]. The test personnel shall wear appropriate clean clothes and gloves, and the test instruments and other required articles shall be clean and free of particles, so as to ensure that external contamination will not be introduced in the test environment and thus affecting the test results. 4.2 Prior to test, the fluid for washing shall be inspected for blank test in the same way as the fluid after washing in the corresponding test. For the purpose of the blank test, the requirement that the particle contamination of 500mL of the fluid for washing is not more than 9 shall be met. If the fluid for washing required for the test is of other volumes, its contamination index shall be converted according to the multiple relationship between the volume of the fluid for washing and 500mL. 4.3 For fluids after washing in each test, the particles shall be classified and counted according to those specified in Table 1, and the contamination index shall be calculated according to clause 12. 4.4 The particle counter used shall be calibrated at least once every year. 5 Size classification and evaluation coefficients of particles See Table 1 for the size classification and corresponding evaluation coefficient of particles in the fluids for washing and fluids after washing. Table 1 Size classification and evaluation coefficients of particles causing contamination Parameter Size classification Particle size/μm 25~50 (Category I) 51~100 (Category II) >100 (Category III) Number of particles in the sample na1 na2 na3 Number of particles in blank test nb1 nb2 nb3 Evaluation coefficient 0.1 0.2 5 6 Principle Select the appropriate fluids for washing to wash the test pieces with the specified method, and use the appropriate counting method to classify and count the particles in the fluids for washing (3.2).
Contents of YY/T 1556-2017
Foreword i Introduction ii 1 Scope 2 Normative references 3 Terms and definitions 4 General 5 Size classification and evaluation coefficients of particles 6 Principle 7 Apparatus and materials 8 Selection of fluids for washing 9 Selection of counting methods 10 Preparation of fluids after washing 11 Particle counting methods 12 Expression of results 13 Test report