2023-3-27 3.236.241.39
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GA 1264-2015
GA 1264-2015   Fixed fire extinguishing systems for compartment of bus (English Version)
Standard No.: GA 1264-2015 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 10000 words Price(USD):250.0 remind me the price change

Email:

Implemented on:2015-8-1 Delivery: via email in 1 business day
,,
Standard No.: GA 1264-2015
English Name: Fixed fire extinguishing systems for compartment of bus
Chinese Name: 公共汽车客舱固定灭火系统
Chinese Classification: C84    Fire-fighting equipment and devices
Professional Classification: GA    Professional Standard - Security
ICS Classification: 13.220.10 13.220.10    Fire-fighting 13.220.10
Issued by: MPS
Issued on: 2015-06-29
Implemented on: 2015-8-1
Status: superseded
Superseded by:XF 1264-2015 Fixed fire extinguishing systems for compartment of bus
Superseded on:2015-8-1
Language: English
File Format: PDF
Word Count: 10000 words
Price(USD): 250.0
Delivery: via email in 1 business day
1 Scope This standard specifies the terms and definitions, model compilation, requirements, test method, inspection rules, marking, packaging, transportation and storage, system design, installation, debugging and acceptance, as well as maintenance and management of fixed fire extinguishing systems for compartment of bus. This standard is applicable to fixed fire extinguishing system for compartment of single-deck bus which takes water based extinguishing agent and foam extinguishing agent as the fire extinguishing medium. 2 Normative References The following documents are indispensable for the application of this document. For dated reference, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendment) applies. GB/T 191 Packaging - Pictorial Marking for Handling of Goods GB/T 2423.1 Environmental Testing for Electric and Electronic Products - Part 1: Test Methods - Test A: Cold GB/T 2423.2 Environmental Testing for Electric and Electronic Products - Part 2: Test Methods - Test B: Dry Heat GB/T 2423.3 Environmental Testing for Electric and Electronic Products - Part 3: Test Methods - Test Cab: Damp Heat Steady State GB/T 2423.5 Environmental Testing for Electric and Electronic Products - Part 5: Test Methods - Test Ea and Guidance: Shock GB/T 2423.10 Environmental Testing for Electric and Electronic Products - Part 10: Test Methods - Test Fc: Vibration (Sinusoidal) GB 5135.3-2003 Automatic Sprinkler System - Part 3: Water Mist Nozzles GB 6245-2006 Fire Pumps GB/T 9969 General Principles for Preparation of Instructions for Use of Industrial Products GB/T 13043 Bus and Coach - Engineering Approval Evaluation Process GB 15308-2006 Foam Extinguishing Agent GB/T 17626.14-2005 Electromagnetic Compatibility - Testing and Measurement Techniques - Voltage Fluctuation Immunity Test GB 17835 Water Based Extinguishing Agent GA 306.2-2007 Flame Retardant and Fire Resistive Cables - Classification and Requirement for Flame Retardant and Fire Resistive Characteristics of Plastic Insulated Electric Cables - Part 2: Fire Resistive Cables HJ/T 153-2004 The Guidelines for the Testing of Chemicals HJ/T 154 The Guidelines for the Hazard Evaluation of New Chemical Substances 3 Terms and Definitions
Foreword i Introduction ii 1 Scope 2 Normative References 3 Terms and Definitions 4 Model Compilation 5 Requirements 5.1 System 5.2 Nozzle 5.3 Conveying Pipe and Pipe Fittings of Extinguishing Agent 5.4 Driving Device 5.5 Extinguishing Agent Storage System 5.6 Extinguishing Agent 5.7 Actuating Device 6 Test Method 6.1 System 6.2 Nozzle 6.3 Extinguishing Agent Conveying Pipe 6.4 Driving Device 6.5 Extinguishing Agent Storage System 6.6 Extinguishing Agent 6.7 Starting Device 7 Inspection Rules 8 Marking, Packaging, Transportation and Storage 9 System Design 10 Installation, Commissioning and Acceptance 11 Maintenance Management Appendix A (Normative) System Operation Reliability Test Appendix B (Informative) Arrangement of 12m-long Bus Extinguishing Test Appendix C (Normative) System Function Test Procedure and Sample Quantity Appendix D (Normative) Nozzle Test Procedure and Sample Quantity Appendix E (Normative) Extinguishing Agent Conveying Pipeline Test Procedure and Sample Quantity Appendix F (Normative) Driving Pump Test Procedure and Sample Quantity Appendix G (Normative) Extinguishing Agent Storage Device Test Procedure and Sample Quantity Appendix H (Normative) Actuating Device Test Procedure and Sample Quantity Appendix I (Informative) Equivalent Length of Pipe Fitting and Valve Appendix J (Normative) System Installation Quality Inspection Record Appendix K (Normative) System Maintenance Inspection Items
Referred in GA 1264-2015:
* GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods
* GB/T 2423.1-2008 Environmental testing - Part 2: Test methods - Tests A: Cold
* GB/T 2423.2-2008 Environmental testing - Part 2: Test methods - Tests B: Dry heat
* GB/T 2423.3-2006 Environmental testing for electric and electronic products - Part 2: Testing method test Cab: Damp heat Steady state
* GB/T 2423.5-1995 Environmental testing for electric and electronic products Part 2:Test methods Test Ea and guidance:Shock
* GB/T 2423.10-2008 Environmental testing for electric and electronic products - Part 2: Tests methods - Test Fc: Vibration (sinusoidal)
* GB 5135.3-2003 Automatic sprinkler system—Part 3:Water mist nozzles
* GB 6245-2006 Fire Pumps
* GB/T 9969-2008 General Principles for Preparation of Instructions for Use of Industrial Products
* GB/T 13043-2006 Bus and coach - Engineering approval evaluation process
* GB 15308-2006 Foam extinguishing agent
* GB/T 17626.14-2005 Electromagetic Compatibility - Testing and measurement techniques - Voltage fluctuation immunity test
* GB 17835-2008 Water beased extinguishing agent
* GA 306.2-2007 Flame retardant and fire resistive cables—Classification and requirement for flame retardant and fire resistive characteristics of platic insulated cables—Part 2:Fire resistive cables
* HJ/T 153-2004 The guidelines for the testing of chemicals
* HJ/T 154-2004 The guidelines for the hazard evaluation of new chemical substances
GA 1264-2015 is referred in:
*GB 7258-2017 Technical Specifications for Safety of Power-driven Vehicles Operating on Roads
*GB 7258-2017/XG2-2021 Technical specifications for safety of power-driven vehicles operating on roads,includes Amendment 2
Code of China
Standard
GA 1264-2015  Fixed fire extinguishing systems for compartment of bus (English Version)
Standard No.GA 1264-2015
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count10000 words
Price(USD)250.0
Implemented on2015-8-1
Deliveryvia email in 1 business day
Detail of GA 1264-2015
Standard No.
GA 1264-2015
English Name
Fixed fire extinguishing systems for compartment of bus
Chinese Name
公共汽车客舱固定灭火系统
Chinese Classification
C84
Professional Classification
GA
ICS Classification
Issued by
MPS
Issued on
2015-06-29
Implemented on
2015-8-1
Status
superseded
Superseded by
XF 1264-2015 Fixed fire extinguishing systems for compartment of bus
Superseded on
2015-8-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
10000 words
Price(USD)
250.0
Keywords
GA 1264-2015, GA/T 1264-2015, GAT 1264-2015, GA1264-2015, GA 1264, GA1264, GA/T1264-2015, GA/T 1264, GA/T1264, GAT1264-2015, GAT 1264, GAT1264
Introduction of GA 1264-2015
1 Scope This standard specifies the terms and definitions, model compilation, requirements, test method, inspection rules, marking, packaging, transportation and storage, system design, installation, debugging and acceptance, as well as maintenance and management of fixed fire extinguishing systems for compartment of bus. This standard is applicable to fixed fire extinguishing system for compartment of single-deck bus which takes water based extinguishing agent and foam extinguishing agent as the fire extinguishing medium. 2 Normative References The following documents are indispensable for the application of this document. For dated reference, only the edition cited applies. For undated references, the latest edition of the normative document (including any amendment) applies. GB/T 191 Packaging - Pictorial Marking for Handling of Goods GB/T 2423.1 Environmental Testing for Electric and Electronic Products - Part 1: Test Methods - Test A: Cold GB/T 2423.2 Environmental Testing for Electric and Electronic Products - Part 2: Test Methods - Test B: Dry Heat GB/T 2423.3 Environmental Testing for Electric and Electronic Products - Part 3: Test Methods - Test Cab: Damp Heat Steady State GB/T 2423.5 Environmental Testing for Electric and Electronic Products - Part 5: Test Methods - Test Ea and Guidance: Shock GB/T 2423.10 Environmental Testing for Electric and Electronic Products - Part 10: Test Methods - Test Fc: Vibration (Sinusoidal) GB 5135.3-2003 Automatic Sprinkler System - Part 3: Water Mist Nozzles GB 6245-2006 Fire Pumps GB/T 9969 General Principles for Preparation of Instructions for Use of Industrial Products GB/T 13043 Bus and Coach - Engineering Approval Evaluation Process GB 15308-2006 Foam Extinguishing Agent GB/T 17626.14-2005 Electromagnetic Compatibility - Testing and Measurement Techniques - Voltage Fluctuation Immunity Test GB 17835 Water Based Extinguishing Agent GA 306.2-2007 Flame Retardant and Fire Resistive Cables - Classification and Requirement for Flame Retardant and Fire Resistive Characteristics of Plastic Insulated Electric Cables - Part 2: Fire Resistive Cables HJ/T 153-2004 The Guidelines for the Testing of Chemicals HJ/T 154 The Guidelines for the Hazard Evaluation of New Chemical Substances 3 Terms and Definitions
Contents of GA 1264-2015
Foreword i Introduction ii 1 Scope 2 Normative References 3 Terms and Definitions 4 Model Compilation 5 Requirements 5.1 System 5.2 Nozzle 5.3 Conveying Pipe and Pipe Fittings of Extinguishing Agent 5.4 Driving Device 5.5 Extinguishing Agent Storage System 5.6 Extinguishing Agent 5.7 Actuating Device 6 Test Method 6.1 System 6.2 Nozzle 6.3 Extinguishing Agent Conveying Pipe 6.4 Driving Device 6.5 Extinguishing Agent Storage System 6.6 Extinguishing Agent 6.7 Starting Device 7 Inspection Rules 8 Marking, Packaging, Transportation and Storage 9 System Design 10 Installation, Commissioning and Acceptance 11 Maintenance Management Appendix A (Normative) System Operation Reliability Test Appendix B (Informative) Arrangement of 12m-long Bus Extinguishing Test Appendix C (Normative) System Function Test Procedure and Sample Quantity Appendix D (Normative) Nozzle Test Procedure and Sample Quantity Appendix E (Normative) Extinguishing Agent Conveying Pipeline Test Procedure and Sample Quantity Appendix F (Normative) Driving Pump Test Procedure and Sample Quantity Appendix G (Normative) Extinguishing Agent Storage Device Test Procedure and Sample Quantity Appendix H (Normative) Actuating Device Test Procedure and Sample Quantity Appendix I (Informative) Equivalent Length of Pipe Fitting and Valve Appendix J (Normative) System Installation Quality Inspection Record Appendix K (Normative) System Maintenance Inspection Items
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GA 1264-2015, GA/T 1264-2015, GAT 1264-2015, GA1264-2015, GA 1264, GA1264, GA/T1264-2015, GA/T 1264, GA/T1264, GAT1264-2015, GAT 1264, GAT1264