2023-1-28 3.235.25.27
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 12955-2008
GB 12955-2008   Fire-resistant Door Sets (English Version)
Standard No.: GB 12955-2008 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 5000 words Price(USD):80.0 remind me the price change

Email:

Implemented on:2009-1-1 Delivery: via email in 1 business day
,,
Standard No.: GB 12955-2008
English Name: Fire-resistant Door Sets
Chinese Name: 防火门
Chinese Classification: C82    Fire protection technology
Professional Classification: GB    National Standard
ICS Classification: 13.220.50 13.220.50    Fire-resistance of building materials and elements 13.220.50
Issued by: AQSIQ, SAC
Issued on: 2008-04-22
Implemented on: 2009-1-1
Status: valid
Superseding:GB 12955-1991 General technical conditions for steel fire door
GB 14101-1993 Wood fire door-General technical conditions
Language: English
File Format: PDF
Word Count: 5000 words
Price(USD): 80.0
Delivery: via email in 1 business day
1 Scope This national standard specifies the classification, code name, tag, requirement, test method, test rules, sign, packing, transportation and storage of the fire resistant door sets. This standard is applicable to timber, steel and timber-steel fire resistant hung door sets and other material fire resistant door sets. As for other open mode fire resistant door sets, refer to this standard. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this standard. For date reference, the subsequent amendments to (excluding amending error in the text) or revisions of, any of these publications do not apply. And parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. For undated references, its latest edition referred to applies. GB/T 708 Dimension shape weight and tolerance for cold-rolled steel plates and sheets GB/T 709 Dimensions, shape, weight and tolerances for hot-rolled plates and sheets GB/T 2828.1 Sampling procedures for inspection by attributea-Part1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection GB/T 4823-1995 Defects in sawn timber (eqv ISO 1029:1974) GB/T 5823-1986 Doors and windows for building-Terminology GB/T 5824 Size system of opening for windows and doors in building GB/T 5907-1986 Fundamental terminology of fire protection; Part 1 GB/T 6388 Transport package shipping mark GB/T 7633 Fire resistance tests - Door and shutter assemblies GB 8624-2006 Classification for burning behavior of building materials and products GB/T 8625-2005 Test method of difficult-flammability for building materials GB 9969.1 General principles for preparation of instructions for use of industrial products GB/T 13306 Plates GB/T 14436 General principles of industrial product guarantee documents GB 15763.1 Safety glazing materials in building Fire-resistant glass GB 16807 Fire intumescent seals GB/T 20285-2006 Toxic classification of fire effluents hazard for materials GA 93 Fire resistant door sets closer JG/T 122-2000 Wood doors and windows for building QB/T 2474 Pin tumbler mortise door lock 3 Terminologies and Definitions Terminologies and definitions stipulated in GB/T 5823-1986 and GB/T 5907-1986 as well as the following terminologies and definitions are applicable in this standard. 3.1 Fire resistant side hung door sets This is formed by door wing, fireproofing hinge and fireproofing lock. Hinge is the shaft perpendicular to the floor, this shaft can rotate clockwise or counterclockwise to open or shut the fire resistant door sets of the door wing. 3.2 Fire resistant timber door sets Use the flame resisting timber, flame resisting timberwork to make the doorframe, door wing frame, door wing panel and filling material within the door wing, then fill the fireproofing heat insulating material that is harmless for the human, then form the door with the fire resisting property by assembling with the hardware fittings. 3.3 Fire resistant steel door sets Use the steel material to make the doorframe, door wing frame, door wing panel and fill material within the door wing, then fill the fireproofing heat insulating material that is harmless for the human, then form the door with the fire resisting property by assembling with the hardware fittings. 3.4 Fire resistant timber door sets with steel structure Use the steel material, flame resisting woodiness material or flame resisting timberwork to fabricate the doorframe, door wing frame, door wing panel and filling material within the door wing, then fill the fireproofing heat insulating material that is harmless for the human, then form the door with the fire resisting property by assembling with the hardware fittings. 3.5 Other material fire resistant door sets Use the inorganic noncombustible material, steel, flame resisting timber and flame resisting timberwork but not the steel material, flame resisting wood or flame resisting timberwork to fabricate the doorframe, door wing frame, door wing panel and filling material, then fill the fireproofing heat insulating material that is harmless for the human, then form the door with fire resisting property by assembling the hardware fittings. 3.6 Fully insulated door sets Within the time specified, this door set can meet the requirements for fireproof integrality and ablative insulating quality. 3.7 Partially insulated door sets Within 0.50 h greater than or equal to the requirement, fireproof integrality and ablative insulating quality requirement can be met; when 0.50 h is exceeded, fireproof integrality requirement of the fire resistant door sets can also be met. 3.8 No insulated door sets Within the time specified, the door set can meet the requirements for fireproof integrality and ablative insulating quality.
Foreword 1 Scope 2 The normative references 3 Terminologies and Definition 4 Classification, code name and tag 5 Requirements 5.1 General requirements 5.2 Material 5.3 Fittings 5.4 Processing technique and appearance quality 5.5 Door wing quality 5.6 Size limit deviation 5.7 Form-position tolerance 5.8 Tolerance of fit 5.9 Flexibility 5.10 Reliability 6 Test methods 6.1 Requirement for specimen 6.2 Accuracy of instrument and equipment 6.3 Material 6.4 Fittings 6.5 Processing technique and appearance quality 6.6 Door wing quality 6.7 Dimensional Tolerance 6.8 Tolerance of Form and Position 6.9 Fit Tolerance 6.10 Flexibility 6.11 Reliability 6.12 Fire Resistance 7 Test Rules 7.1 Delivery Test 7.2 Version Inspection 8 Mark, Package, Transportation and Storage Annex A (Normative Annex) Requirements and Test Methods of Flameproof Lock Annex B (Normative Annex) Fire Resistance Requirements and Test Methods of the Fire Resistant Gemel (Hinge) Annex C (Normative Annex) Fire Resistance Requirements and Test Methods of Fire Resistant Sequence Controller Annex D (Normative Annex) Fire Resistance Requirements and Test Methods of Fire Resistant Bolt
Referred in GB 12955-2008:
*GB/T 708-2006 Dimension, Shape, Weight, and Tolerance for Cold-Rolled Steel Plat
*GB/T 709-2006 Dimension, Shape, Weight and Tolerances for Hot Rolled Sheets and
*GB/T 2828.1-2012 Sampling procedures for inspection by attributea-Part1:Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
*GB/T 4823-1995 Defects in sawn timber
*GB/T 5823-1986 Doors and windows for building-Term inology
*GB/T 5824-2008 Size system of opening for windows and doors in building
*GB/T 5907-1986
*GB/T 6388-1986
*GB/T 7633-2008 Fire resistance tests - Door and shutter assemblies
*GB 8624-2006 Classification for Burning Behavior of Building Materials and Products
*GB/T 8625-2005 Test method of difficult-flammability for building materials
*GB 9969.1-1998 General principles for preparation of instructions for use of industrial products
*GB/T 13306-2011 Plate
*GB/T 14436-1993 General Principles of Industrial Product Guarantee Documents
*GB 15763.1-2009 Safety glazing materials in building - Part 1: Fire-resistant glass
*GB 16807-2009 Fire intumescent seals
*GB/T 20285-2006 Toxic classification of fire effluents hazard for materials
*GA 93-2004 Fire - Proof door closer
*JG/T 122-2000 Wood doors and windows for building
*QB/T 2474-2017
GB 12955-2008 is referred in:
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 16807-2009 Fire intumescent seals
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
* GB 50016-2014 Code of Design on Building Fire Protection and Prevention
Code of China
Standard
GB 12955-2008  Fire-resistant Door Sets (English Version)
Standard No.GB 12955-2008
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)80.0
Implemented on2009-1-1
Deliveryvia email in 1 business day
Detail of GB 12955-2008
Standard No.
GB 12955-2008
English Name
Fire-resistant Door Sets
Chinese Name
防火门
Chinese Classification
C82
Professional Classification
GB
ICS Classification
Issued by
AQSIQ, SAC
Issued on
2008-04-22
Implemented on
2009-1-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 12955-1991 General technical conditions for steel fire door
GB 14101-1993 Wood fire door-General technical conditions
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
80.0
Keywords
GB 12955-2008, GB/T 12955-2008, GBT 12955-2008, GB12955-2008, GB 12955, GB12955, GB/T12955-2008, GB/T 12955, GB/T12955, GBT12955-2008, GBT 12955, GBT12955
Introduction of GB 12955-2008
1 Scope This national standard specifies the classification, code name, tag, requirement, test method, test rules, sign, packing, transportation and storage of the fire resistant door sets. This standard is applicable to timber, steel and timber-steel fire resistant hung door sets and other material fire resistant door sets. As for other open mode fire resistant door sets, refer to this standard. 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this standard. For date reference, the subsequent amendments to (excluding amending error in the text) or revisions of, any of these publications do not apply. And parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. For undated references, its latest edition referred to applies. GB/T 708 Dimension shape weight and tolerance for cold-rolled steel plates and sheets GB/T 709 Dimensions, shape, weight and tolerances for hot-rolled plates and sheets GB/T 2828.1 Sampling procedures for inspection by attributea-Part1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection GB/T 4823-1995 Defects in sawn timber (eqv ISO 1029:1974) GB/T 5823-1986 Doors and windows for building-Terminology GB/T 5824 Size system of opening for windows and doors in building GB/T 5907-1986 Fundamental terminology of fire protection; Part 1 GB/T 6388 Transport package shipping mark GB/T 7633 Fire resistance tests - Door and shutter assemblies GB 8624-2006 Classification for burning behavior of building materials and products GB/T 8625-2005 Test method of difficult-flammability for building materials GB 9969.1 General principles for preparation of instructions for use of industrial products GB/T 13306 Plates GB/T 14436 General principles of industrial product guarantee documents GB 15763.1 Safety glazing materials in building Fire-resistant glass GB 16807 Fire intumescent seals GB/T 20285-2006 Toxic classification of fire effluents hazard for materials GA 93 Fire resistant door sets closer JG/T 122-2000 Wood doors and windows for building QB/T 2474 Pin tumbler mortise door lock 3 Terminologies and Definitions Terminologies and definitions stipulated in GB/T 5823-1986 and GB/T 5907-1986 as well as the following terminologies and definitions are applicable in this standard. 3.1 Fire resistant side hung door sets This is formed by door wing, fireproofing hinge and fireproofing lock. Hinge is the shaft perpendicular to the floor, this shaft can rotate clockwise or counterclockwise to open or shut the fire resistant door sets of the door wing. 3.2 Fire resistant timber door sets Use the flame resisting timber, flame resisting timberwork to make the doorframe, door wing frame, door wing panel and filling material within the door wing, then fill the fireproofing heat insulating material that is harmless for the human, then form the door with the fire resisting property by assembling with the hardware fittings. 3.3 Fire resistant steel door sets Use the steel material to make the doorframe, door wing frame, door wing panel and fill material within the door wing, then fill the fireproofing heat insulating material that is harmless for the human, then form the door with the fire resisting property by assembling with the hardware fittings. 3.4 Fire resistant timber door sets with steel structure Use the steel material, flame resisting woodiness material or flame resisting timberwork to fabricate the doorframe, door wing frame, door wing panel and filling material within the door wing, then fill the fireproofing heat insulating material that is harmless for the human, then form the door with the fire resisting property by assembling with the hardware fittings. 3.5 Other material fire resistant door sets Use the inorganic noncombustible material, steel, flame resisting timber and flame resisting timberwork but not the steel material, flame resisting wood or flame resisting timberwork to fabricate the doorframe, door wing frame, door wing panel and filling material, then fill the fireproofing heat insulating material that is harmless for the human, then form the door with fire resisting property by assembling the hardware fittings. 3.6 Fully insulated door sets Within the time specified, this door set can meet the requirements for fireproof integrality and ablative insulating quality. 3.7 Partially insulated door sets Within 0.50 h greater than or equal to the requirement, fireproof integrality and ablative insulating quality requirement can be met; when 0.50 h is exceeded, fireproof integrality requirement of the fire resistant door sets can also be met. 3.8 No insulated door sets Within the time specified, the door set can meet the requirements for fireproof integrality and ablative insulating quality.
Contents of GB 12955-2008
Foreword 1 Scope 2 The normative references 3 Terminologies and Definition 4 Classification, code name and tag 5 Requirements 5.1 General requirements 5.2 Material 5.3 Fittings 5.4 Processing technique and appearance quality 5.5 Door wing quality 5.6 Size limit deviation 5.7 Form-position tolerance 5.8 Tolerance of fit 5.9 Flexibility 5.10 Reliability 6 Test methods 6.1 Requirement for specimen 6.2 Accuracy of instrument and equipment 6.3 Material 6.4 Fittings 6.5 Processing technique and appearance quality 6.6 Door wing quality 6.7 Dimensional Tolerance 6.8 Tolerance of Form and Position 6.9 Fit Tolerance 6.10 Flexibility 6.11 Reliability 6.12 Fire Resistance 7 Test Rules 7.1 Delivery Test 7.2 Version Inspection 8 Mark, Package, Transportation and Storage Annex A (Normative Annex) Requirements and Test Methods of Flameproof Lock Annex B (Normative Annex) Fire Resistance Requirements and Test Methods of the Fire Resistant Gemel (Hinge) Annex C (Normative Annex) Fire Resistance Requirements and Test Methods of Fire Resistant Sequence Controller Annex D (Normative Annex) Fire Resistance Requirements and Test Methods of Fire Resistant Bolt
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 12955-2008, GB/T 12955-2008, GBT 12955-2008, GB12955-2008, GB 12955, GB12955, GB/T12955-2008, GB/T 12955, GB/T12955, GBT12955-2008, GBT 12955, GBT12955