2023-1-28 3.235.25.27
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 16806-2006
GB 16806-2006   Automatic control system for fire protection (English Version)
Standard No.: GB 16806-2006 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 35000 words Price(USD):870.0 remind me the price change

Email:

Implemented on:2007-4-1 Delivery: via email in 1 business day
,,
Standard No.: GB 16806-2006
English Name: Automatic control system for fire protection
Chinese Name: 消防联动控制系统
Chinese Classification: C81    Fire monitoring, alarming and fire-fighting dispatching system
Professional Classification: GB    National Standard
ICS Classification: 13.220.20 13.220.20    Fire protection 13.220.20
Issued by: AQSIQ and SAC
Issued on: 2006-07-16
Implemented on: 2007-4-1
Status: superseded
Superseded by:GB 16806-2006/XG1-2016 Automatic control system for fire protection
Superseded on:2016-5-1
Superseding:GB 16806-1997 General technical conditions of control for fire protection equipment
Language: English
File Format: PDF
Word Count: 35000 words
Price(USD): 870.0
Delivery: via email in 1 business day
This standard specifies the definition, general requirements, requirements, test methods, inspection rules and marks of automatic control system for fire protection. This standard is applicable to the automatic control system for fire protection and various equipments thereof used for installation in general industry and civil buildings, including automatic controller for fire protection, gas fire extinguishing controller, electric fire control unit, emergency power supply for fire fighting equipment, fire emergency broadcasting equipment, fire telephone, transmission equipment, graphic display unit in fire protection control room, module, electric fire device and fire hydrant button. As for the automatic control system for fire protection and various equipments thereof with special performance used and installed in other environments, except the special requirements which are specified by relevant standards, this standard shall also be implemented.
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 General Requirements 4.1 General Requirements of Automatic Control System for Fire Protection 4.2 Automatic Controller for Fire Protection 4.3 Gas Fire Extinguishing Controller 4.4 Electric Fire Control Unit 4.5 Emergency Power Supply for Fire Fighting Equipment 4.6 Fire Emergency Broadcasting Equipment 4.7 Fire Telephone 4.8 Transmission Equipment 4.9 Graphic Display Unit in Fire Protection Control Room 4.10 Module 4.11 Electric fire device 4.12 Fire Hydrant Button 5 Requirements and Test Method 5.1 General Provisions 5.2 Basic performance tests of automatic controller for fire protection 5.3 Basic performance tests of gas fire extinguishing controller 5.4 Basic performance tests of electric fire control unit 5.5 Basic performance tests of fire-fighting emergency power supply 5.6 Basic performance tests of fire emergency broadcasting equipment 5.7 Basic performance tests of fire telephone 5.8 Basic performance tests of transmission equipment 5.9 Basic performance tests of graphic display unit in fire protection control room 5.10 Basic function test of modules 5.11 Basic performance tests of electric fire device 5.12 Basic performance tests of fire hydrant button 5.13 Insulation resistance test 5.14 Leakage current test 5.15 Electric strength test 5.16 Radio frequency electromagnetic field radiation immunity test 5.17 Radio-frequency field inductive conduction disturbances immunity test 5.18 Electrostatic discharge immunity test 5.19 Electrical fast transient burst immunity test 5.20 Surging (impact) immunity test 5.21 Power supply transient test 5.22 Immunity test of voltage dip, short interruption and voltage change 5.23 Low temperature (operation) test 5.24 Constant moist heat (operation) test 5.25 Constant moist heat (durable) test 5.26 Vibration (sine)(operation) test 5.27 Vibration (sine) (durable) experiment 5.28 Impact test 5.29 Shock test 5.30 Rain drop test 5.31 High temperature (operation) test 5.32 Alternating moist heat (operation) test 5.33 SO2 corrosion (durable) test 6 Test Rules 7 Marking Appendix A (Normative) Electromagnetic Performance Requirements
Referred in GB 16806-2006:
*GB 156-2003 STANDARD voltages
*GB 3380-1982 Ringing and tone for telephone automatic switching network
*GB 4706.1-1998 Safety of household and similar electrical appliances Part 1:General requirements
*GB 9969.1-1998 General principles for preparation of instructions for use of industrial products
*GB 12978-2003 Rules for test of fire electronic products
*GB/T 14716-1993 specification for stored program control analogue private automatic branch telephone exchange system
*GB/T 15279-2002 The specifications of automatic telephone set
*GB 16838-2005 Environmental Test Methods and Severities for Fire Electronic Products
*GB/T 17626.2-1998 Electromagnetic compatibility--Testing and measurement techniques--Electrostatic discharge immunity test
*GB/T 17626.3-1998 Electromagnetic compatibility--Testing and measurement techniques-- Radiated,radio-frequency,electromagnetic field immunity test
*GB/T 17626.4-1998 Electromagnetic compatibility-- Testing and measurement techniques --Electrical fast transient/burst immunity test
*GB/T 17626.5-1999 Electromagnetic compatibility--Testing and measurement techniques--Surge immunity test
*GB/T 17626.6-1998 Electromagnetic compatibility --Testing and measurement techniques --Immunity to conducted disturbances,induced by radio-frequency fields
*GB 19880-2005 Manual Fire Call Points
GB 16806-2006 is referred in:
* GB 4717-2005 Fire alarm control units
* GB 50606-2010 Code for installation of Intelligented building system
* GB/T 2887-2011 General specification for computer field
* GB 50116-2013 Code for design of automatic fire alarm system
* GB 50116-2013 Code for design of automatic fire alarm system
* GB/T 2887-2011 General specification for computer field
* GB 50606-2010 Code for installation of Intelligented building system
* GB 22134-2008 Compatibility Requirements of Automatic Fire Alarm System Components
Code of China
Standard
GB 16806-2006   Automatic control system for fire protection (English Version)
Standard No.GB 16806-2006
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count35000 words
Price(USD)870.0
Implemented on2007-4-1
Deliveryvia email in 1 business day
Detail of GB 16806-2006
Standard No.
GB 16806-2006
English Name
Automatic control system for fire protection
Chinese Name
消防联动控制系统
Chinese Classification
C81
Professional Classification
GB
ICS Classification
Issued by
AQSIQ and SAC
Issued on
2006-07-16
Implemented on
2007-4-1
Status
superseded
Superseded by
GB 16806-2006/XG1-2016 Automatic control system for fire protection
Superseded on
2016-5-1
Abolished on
Superseding
GB 16806-1997 General technical conditions of control for fire protection equipment
Language
English
File Format
PDF
Word Count
35000 words
Price(USD)
870.0
Keywords
GB 16806-2006, GB/T 16806-2006, GBT 16806-2006, GB16806-2006, GB 16806, GB16806, GB/T16806-2006, GB/T 16806, GB/T16806, GBT16806-2006, GBT 16806, GBT16806
Introduction of GB 16806-2006
This standard specifies the definition, general requirements, requirements, test methods, inspection rules and marks of automatic control system for fire protection. This standard is applicable to the automatic control system for fire protection and various equipments thereof used for installation in general industry and civil buildings, including automatic controller for fire protection, gas fire extinguishing controller, electric fire control unit, emergency power supply for fire fighting equipment, fire emergency broadcasting equipment, fire telephone, transmission equipment, graphic display unit in fire protection control room, module, electric fire device and fire hydrant button. As for the automatic control system for fire protection and various equipments thereof with special performance used and installed in other environments, except the special requirements which are specified by relevant standards, this standard shall also be implemented.
Contents of GB 16806-2006
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 General Requirements 4.1 General Requirements of Automatic Control System for Fire Protection 4.2 Automatic Controller for Fire Protection 4.3 Gas Fire Extinguishing Controller 4.4 Electric Fire Control Unit 4.5 Emergency Power Supply for Fire Fighting Equipment 4.6 Fire Emergency Broadcasting Equipment 4.7 Fire Telephone 4.8 Transmission Equipment 4.9 Graphic Display Unit in Fire Protection Control Room 4.10 Module 4.11 Electric fire device 4.12 Fire Hydrant Button 5 Requirements and Test Method 5.1 General Provisions 5.2 Basic performance tests of automatic controller for fire protection 5.3 Basic performance tests of gas fire extinguishing controller 5.4 Basic performance tests of electric fire control unit 5.5 Basic performance tests of fire-fighting emergency power supply 5.6 Basic performance tests of fire emergency broadcasting equipment 5.7 Basic performance tests of fire telephone 5.8 Basic performance tests of transmission equipment 5.9 Basic performance tests of graphic display unit in fire protection control room 5.10 Basic function test of modules 5.11 Basic performance tests of electric fire device 5.12 Basic performance tests of fire hydrant button 5.13 Insulation resistance test 5.14 Leakage current test 5.15 Electric strength test 5.16 Radio frequency electromagnetic field radiation immunity test 5.17 Radio-frequency field inductive conduction disturbances immunity test 5.18 Electrostatic discharge immunity test 5.19 Electrical fast transient burst immunity test 5.20 Surging (impact) immunity test 5.21 Power supply transient test 5.22 Immunity test of voltage dip, short interruption and voltage change 5.23 Low temperature (operation) test 5.24 Constant moist heat (operation) test 5.25 Constant moist heat (durable) test 5.26 Vibration (sine)(operation) test 5.27 Vibration (sine) (durable) experiment 5.28 Impact test 5.29 Shock test 5.30 Rain drop test 5.31 High temperature (operation) test 5.32 Alternating moist heat (operation) test 5.33 SO2 corrosion (durable) test 6 Test Rules 7 Marking Appendix A (Normative) Electromagnetic Performance Requirements
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 16806-2006, GB/T 16806-2006, GBT 16806-2006, GB16806-2006, GB 16806, GB16806, GB/T16806-2006, GB/T 16806, GB/T16806, GBT16806-2006, GBT 16806, GBT16806