GB 50311-2007   Code for Engineering Design of Generic Cabling System (English Version)
Standard No.: GB 50311-2007 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 32000 words Price(USD):220.0 remind me the price change

Email:

Implemented on:2007-10-1 Delivery: via email in 1 business day
,,
Standard No.: GB 50311-2007
English Name: Code for Engineering Design of Generic Cabling System
Chinese Name: 综合布线工程设计规范
Chinese Classification: P30    Industrial and civil construction engineering in general
Professional Classification: GB    National Standard
Issued by: Ministry of Construction
Issued on: 2007-04-06
Implemented on: 2007-10-1
Status: superseded
Superseded by:GB 50311-2016 Code for engineering design of generic cabling system
Superseded on:2017-4-1
Superseding:GB/T 50311-2000 Code for engineering design of generic cabling system for building and campus
Language: English
File Format: PDF
Word Count: 32000 words
Price(USD): 220.0
Delivery: via email in 1 business day
1.0.1 So as to coordinate the development of modernization town information communication network to digitalization direction and specify the integrated network construction of the voice, data, image and multimedia business of building and campus, the code is worked out. 1.0.2 The code is suitable for newly-built, extended and rebuilt construction and campus integrative wiring system engineering design. 1.0.3 The integrative wiring system facility and pipeline construction should bring under relevant planning and design for construction and campus. In the engineering design, it should be designed according to engineering project property, function, environmental condition and short-term and long-term user requirement, and the construction and maintenance convenience should be taken into consideration, ensuring quality and security of integrative wiring system engineering as well as achieving state-of-art technology and economic feasibility. 1.0.4 The integrative wiring system should be planned and coordinated together with information facility system, informatization application System, public safety system, building equipment management system, and the design should be optimized according to various system information transmission requirement. 1.0.5 As the public communication self-contained facilities of the building, the integrative wiring system should satisfy demand of providing business for many telecommunication service operators. 1.0.6 The integrative wiring system equipment should adopt the approved products which are ratified by state approved production quality test organization and conformed to related technical standards. 1.0.7 Besides this Code, the integrative wiring system also should conform to prescription of state current related standards.
1. General principles 2. Terms and symbols 2.1 Terms 2.2 Symbol and abbreviation 3 System Design 3.1 System formation 3.2 System classification and composition 3.3 Cable length division 3.4 System applications 3.5 Screened cabling system 3.6 Open type office wiring system 3.7 Industrial grade wiring system 4 System Configuration Design 4.1 Work area 4.2 Cabling subsystem 4.3 Backbone subsystem 4.4 Campus subsystem 4.5 Equipment room 4.6 Lead-in room 4.7 Management 5 System Indicator 6 Installation Process Requirement 6.1 Work area 6.2 Telecommunications room 6.3 Equipment room 6.4 Lead-in room 6.5 Cable distributing 7 Electric Protection and Earthing 8 Fire Prevention
GB 50311-2007 is referred in:
* JGJ 218-2010 Design code for exhibition building
* GB 50606-2010 Code for installation of Intelligented building system
* GB 50049-2011 Code for design of small fossil fired power plant
* GB 50049-2011 Code for design of small fossil fired power plant
* JGJ 218-2010 Design code for exhibition building
* GB 50606-2010 Code for installation of Intelligented building system
* GB 50049-2011 Code for design of small fossil fired power plant
* JGJ 62-2014 Code for Design of Hotel Building
* QX/T 162-2012 Technical Specification for Lightning Protection of Wind Profiler Station
* GB 51039-2014 Code for design of general hospital
* JGJ 312-2013 Code for Electrical Design of Medical Buildings
* GB 50314-2015 Standard for design of intelligent building
* GB 51093-2015 Technical code for hydrochloric acid regeneration engineering according to spraying and roasting technology of iron and steel enterprises
*NB/T 20263-2014 Design Standard of Communication System of Nuclear Power Plants
Code of China
Standard
GB 50311-2007  Code for Engineering Design of Generic Cabling System (English Version)
Standard No.GB 50311-2007
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count32000 words
Price(USD)220.0
Implemented on2007-10-1
Deliveryvia email in 1 business day
Detail of GB 50311-2007
Standard No.
GB 50311-2007
English Name
Code for Engineering Design of Generic Cabling System
Chinese Name
综合布线工程设计规范
Chinese Classification
P30
Professional Classification
GB
ICS Classification
Issued by
Ministry of Construction
Issued on
2007-04-06
Implemented on
2007-10-1
Status
superseded
Superseded by
GB 50311-2016 Code for engineering design of generic cabling system
Superseded on
2017-4-1
Abolished on
Superseding
GB/T 50311-2000 Code for engineering design of generic cabling system for building and campus
Language
English
File Format
PDF
Word Count
32000 words
Price(USD)
220.0
Keywords
GB 50311-2007, GB/T 50311-2007, GBT 50311-2007, GB50311-2007, GB 50311, GB50311, GB/T50311-2007, GB/T 50311, GB/T50311, GBT50311-2007, GBT 50311, GBT50311
Introduction of GB 50311-2007
1.0.1 So as to coordinate the development of modernization town information communication network to digitalization direction and specify the integrated network construction of the voice, data, image and multimedia business of building and campus, the code is worked out. 1.0.2 The code is suitable for newly-built, extended and rebuilt construction and campus integrative wiring system engineering design. 1.0.3 The integrative wiring system facility and pipeline construction should bring under relevant planning and design for construction and campus. In the engineering design, it should be designed according to engineering project property, function, environmental condition and short-term and long-term user requirement, and the construction and maintenance convenience should be taken into consideration, ensuring quality and security of integrative wiring system engineering as well as achieving state-of-art technology and economic feasibility. 1.0.4 The integrative wiring system should be planned and coordinated together with information facility system, informatization application System, public safety system, building equipment management system, and the design should be optimized according to various system information transmission requirement. 1.0.5 As the public communication self-contained facilities of the building, the integrative wiring system should satisfy demand of providing business for many telecommunication service operators. 1.0.6 The integrative wiring system equipment should adopt the approved products which are ratified by state approved production quality test organization and conformed to related technical standards. 1.0.7 Besides this Code, the integrative wiring system also should conform to prescription of state current related standards.
Contents of GB 50311-2007
1. General principles 2. Terms and symbols 2.1 Terms 2.2 Symbol and abbreviation 3 System Design 3.1 System formation 3.2 System classification and composition 3.3 Cable length division 3.4 System applications 3.5 Screened cabling system 3.6 Open type office wiring system 3.7 Industrial grade wiring system 4 System Configuration Design 4.1 Work area 4.2 Cabling subsystem 4.3 Backbone subsystem 4.4 Campus subsystem 4.5 Equipment room 4.6 Lead-in room 4.7 Management 5 System Indicator 6 Installation Process Requirement 6.1 Work area 6.2 Telecommunications room 6.3 Equipment room 6.4 Lead-in room 6.5 Cable distributing 7 Electric Protection and Earthing 8 Fire Prevention