2025-5-24 18.97.14.83
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 18890.2-2015
GB/T 18890.2-2015   Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 2:Power cables (English Version)
Standard No.: GB/T 18890.2-2015 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 10500 words Price(USD):120.0 remind me the price change

Email:

Implemented on:2016-5-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 18890.2-2015
English Name: Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 2:Power cables
Chinese Name: 额定电压220kV(Um=252 kV)交联聚乙烯绝缘电力电缆及其附件 第2部分:电缆
Chinese Classification: K13    Cable and its accessory
Professional Classification: GB    National Standard
Issued by: AQSIQ;SAC
Issued on: 2015-10-09
Implemented on: 2016-5-1
Status: valid
Superseding:GB/Z 18890.2-2002 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220kV (Um=252kV) - Part 2: Power cables with cross-linked polyethylene insulation fo
Language: English
File Format: PDF
Word Count: 10500 words
Price(USD): 120.0
Delivery: via email in 1 business day
1 Scope This part of GB/T 18890 specifies model naming, technical requirements, test and acceptance regulations, packaging, transport and storage of permanently installed power cables with cross-linked polyethylene insulation with rated voltage of 220kV (Um=252kV). This part is applicable to single-core cable used under general installation and operation conditions but not applicable to cable used under special conditions like submarine cable. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 494-2010 Asphalt Used in Roofing GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 11: Methods for General Application - Measurement of Thickness and Overall Dimensions - Tests for Determining The Mechanical Properties GB/T 2951.12-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 12: Methods for General Application - Thermal Ageing Methods GB/T 2951.14-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 14: Methods for General Application - Test at Low Temperature GB/T 2951.21-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 21: Methods Specific to Elastomeric Compounds - Ozone Resistance, Hot Set and Mineral Oil Immersion Tests GB/T 2951.31-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 31: Methods Specific to PVC Compounds - Pressure Test at High Temperature - Test for Resistance to Cracking GB/T 2951.32-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 32: Methods Specific to PVC Compounds - Loss of Mass Test - Thermal Stability Test GB/T 2951.41-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 41: Methods Specific to Polyethylene and Polypropylene Compounds - Resistance to Environmental Stress Cracking - Measurement of The Melt Flow Index - Carbon Black and/or Mineral Filler Content Measurement in Polyethylene by Direct Combustion – Measurement of Carbon Black Content by Thermo Gravimetric Analysis (TGA) – Assessment of Carbon Black Dispersion in Polyethylene Using a Microscope GB/T 3048.4-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 4: Test of DC Resistance of Conductors GB/T 3048.8-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 8: AC Voltage Test GB/T 3048.11-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 11: Test for Dielectric Dissipation Factor GB/T 3048.12-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 12: Partial Discharge Test
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Service Characteristics 5 Product Naming 6 Technical Requirements 7 Marking of Complete Cable 8 Test Requirements 9 Acceptance Regulations 10 Packaging, Transport and Storage Annex A (Informative) Service Conditions of Cables Annex B (Informative) Properties of Insulation Materials and Semi-conductive Materials Bibliography
Referred in GB/T 18890.2-2015:
*GB/T 494-2010 Asphalt used in roofing
*GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 11:Methods for general application - Measurement of thickness and overall dimensions
*GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 12: Methods for general application - Thermal ageing methods
*GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 14: Methods for general application - Test at low temperature
*GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 21: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral
*GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 31: Methods specific to PVC compounds - Pressure test at high temperature - Test for
*GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 32: Methods specific to PVC compounds - Loss of mass test - Thermal stability test
*GB/T 2951.41-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 41: Methods specific to polyethylene and polypropylene compounds - Resistance to envi
*GB/T 3048.4-2007 Test methods for electrical properties of electric cables and wires—Part 4:Test of DC resistance of conductors
*GB/T 3048.8-2007 Test methods for electrical properties of electric cables and wires—Part 8:AC voltage test
*GB/T 3048.11-2007 Test methods for electrical properties of electric cables and wires—Part 11:Test for dielectric dissipation factor
*GB/T 3048.12-2007 Test methods for electrical properties of electric cables and wires—Part 12:Partial discharge test
*GB/T 3048.13-2007 Test methods for electrical properties of electric cables and wires—Part 13: Impulse voltage test
*GB/T 3048.14-2007 Test methods for electrical properties of electric cables and wires—Part 14:DC voltage test
*GB/T 3880.1-2012 Wrought aluminium and aluminium alloy plates,sheets and strips for general engineering—Part 1:Technical conditions of delivery
*GB/T 3953-2009 Round copper wire for electrical purposes
*GB/T 3956-2008 Conductors of insulated cables
*GB/T 6995.3-2008 Markings for electric wires and cables - Part 3:Identifications of cables and wires
*GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions - Part 12: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1kW pre-mixed fla
*GB/T 18890.1-2015 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 1:Test methods and requirements
*GB/T 26011-2010 Lead alloy ingot for cable sheath bond
*JB/T 5268.1-2011 Metal sheaths for cables -Part 1:General requirement
*JB/T 10181.11-2014
*JB/T 10259-2014
*JB/T 10696.5-2007 Test methods for determining mechanical physical and chemical properties of electric cables and wires-Part 5:Corrosion spread test
*JB/T 10696.6-2007 Test methods for determining mechanical physical and chemical properties of electric cables and wires-Part 6:Test for abrasion of oversheaths
GB/T 18890.2-2015 is referred in:
*GB/T 18890.3-2015 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 3:Accessories
Code of China
Standard
GB/T 18890.2-2015  Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 2:Power cables (English Version)
Standard No.GB/T 18890.2-2015
Statusvalid
LanguageEnglish
File FormatPDF
Word Count10500 words
Price(USD)120.0
Implemented on2016-5-1
Deliveryvia email in 1 business day
Detail of GB/T 18890.2-2015
Standard No.
GB/T 18890.2-2015
English Name
Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(Um=252 kV)―Part 2:Power cables
Chinese Name
额定电压220kV(Um=252 kV)交联聚乙烯绝缘电力电缆及其附件 第2部分:电缆
Chinese Classification
K13
Professional Classification
GB
ICS Classification
Issued by
AQSIQ;SAC
Issued on
2015-10-09
Implemented on
2016-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/Z 18890.2-2002 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220kV (Um=252kV) - Part 2: Power cables with cross-linked polyethylene insulation fo
Language
English
File Format
PDF
Word Count
10500 words
Price(USD)
120.0
Keywords
GB/T 18890.2-2015, GB 18890.2-2015, GBT 18890.2-2015, GB/T18890.2-2015, GB/T 18890.2, GB/T18890.2, GB18890.2-2015, GB 18890.2, GB18890.2, GBT18890.2-2015, GBT 18890.2, GBT18890.2
Introduction of GB/T 18890.2-2015
1 Scope This part of GB/T 18890 specifies model naming, technical requirements, test and acceptance regulations, packaging, transport and storage of permanently installed power cables with cross-linked polyethylene insulation with rated voltage of 220kV (Um=252kV). This part is applicable to single-core cable used under general installation and operation conditions but not applicable to cable used under special conditions like submarine cable. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 494-2010 Asphalt Used in Roofing GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 11: Methods for General Application - Measurement of Thickness and Overall Dimensions - Tests for Determining The Mechanical Properties GB/T 2951.12-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 12: Methods for General Application - Thermal Ageing Methods GB/T 2951.14-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 14: Methods for General Application - Test at Low Temperature GB/T 2951.21-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 21: Methods Specific to Elastomeric Compounds - Ozone Resistance, Hot Set and Mineral Oil Immersion Tests GB/T 2951.31-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 31: Methods Specific to PVC Compounds - Pressure Test at High Temperature - Test for Resistance to Cracking GB/T 2951.32-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 32: Methods Specific to PVC Compounds - Loss of Mass Test - Thermal Stability Test GB/T 2951.41-2008 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables - Part 41: Methods Specific to Polyethylene and Polypropylene Compounds - Resistance to Environmental Stress Cracking - Measurement of The Melt Flow Index - Carbon Black and/or Mineral Filler Content Measurement in Polyethylene by Direct Combustion – Measurement of Carbon Black Content by Thermo Gravimetric Analysis (TGA) – Assessment of Carbon Black Dispersion in Polyethylene Using a Microscope GB/T 3048.4-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 4: Test of DC Resistance of Conductors GB/T 3048.8-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 8: AC Voltage Test GB/T 3048.11-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 11: Test for Dielectric Dissipation Factor GB/T 3048.12-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 12: Partial Discharge Test
Contents of GB/T 18890.2-2015
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Service Characteristics 5 Product Naming 6 Technical Requirements 7 Marking of Complete Cable 8 Test Requirements 9 Acceptance Regulations 10 Packaging, Transport and Storage Annex A (Informative) Service Conditions of Cables Annex B (Informative) Properties of Insulation Materials and Semi-conductive Materials Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 18890.2-2015, GB 18890.2-2015, GBT 18890.2-2015, GB/T18890.2-2015, GB/T 18890.2, GB/T18890.2, GB18890.2-2015, GB 18890.2, GB18890.2, GBT18890.2-2015, GBT 18890.2, GBT18890.2