GB/T 223.21-1994 Methods for chemical analysis of iron steel and alloy.The 5-CL-PADAB spectrophotometric method for the determination of cobalt content (English Version)
This standard specifies the 5-Cl-PADAB spectrophotometric method for determination of cobalt content.
This standard is applicable to the determination of cobalt content in carbon steel and alloy steel. Determination range: 0.0050%~0.50%.
2 Principle
After the sample is dissolved with acid, in the solution of pH 7~8, the coordination compound generated by 5-Cl -PADAB and cobalt is acidified with dilute sulfuric acid, and takes on stable aubergine; measure the absorbance.
1 Subject Content and Application Scope 2 Principle 3 Reagent 4 Analytical Procedures 5 Calculation of Analysis Results 6 Precision Appendix A Source Data of Precision Test (Additional) Additional Explanations
GB/T 223.21-1994 Methods for chemical analysis of iron steel and alloy.The 5-CL-PADAB spectrophotometric method for the determination of cobalt content (English Version)
Standard No.
GB/T 223.21-1994
Status
valid
Language
English
File Format
PDF
Word Count
2000 words
Price(USD)
40.0
Implemented on
1994-10-1
Delivery
via email in 1 business day
Detail of GB/T 223.21-1994
Standard No.
GB/T 223.21-1994
English Name
Methods for chemical analysis of iron steel and alloy.The 5-CL-PADAB spectrophotometric method for the determination of cobalt content
1 Subject Content and Application Scope
This standard specifies the 5-Cl-PADAB spectrophotometric method for determination of cobalt content.
This standard is applicable to the determination of cobalt content in carbon steel and alloy steel. Determination range: 0.0050%~0.50%.
2 Principle
After the sample is dissolved with acid, in the solution of pH 7~8, the coordination compound generated by 5-Cl -PADAB and cobalt is acidified with dilute sulfuric acid, and takes on stable aubergine; measure the absorbance.
Contents of GB/T 223.21-1994
1 Subject Content and Application Scope
2 Principle
3 Reagent
4 Analytical Procedures
5 Calculation of Analysis Results
6 Precision
Appendix A Source Data of Precision Test (Additional)