This method is applicable to determine the water content (expressed in percent) in petroleum products.
1 Summary of Method
Certain amount of the sample is mixed with the anhydrous solvent and then is distilled to determine its water content (expressed in percent).
2 Instrument
Water content tester (Figure 1): including the round-bottom flask 1 with a volume of 500mL, acceptor 2 (Figure 2) and straight condenser 3 with a length of 250~300mm.
1 Summary of Method 2 Instrument 3 Material 4 Test Procedures 5 Calculation 6 Precision 7 Report Additional Explanation
This method is applicable to determine the water content (expressed in percent) in petroleum products.
1 Summary of Method
Certain amount of the sample is mixed with the anhydrous solvent and then is distilled to determine its water content (expressed in percent).
2 Instrument
Water content tester (Figure 1): including the round-bottom flask 1 with a volume of 500mL, acceptor 2 (Figure 2) and straight condenser 3 with a length of 250~300mm.
Contents of GB/T 260-1977
1 Summary of Method
2 Instrument
3 Material
4 Test Procedures
5 Calculation
6 Precision
7 Report
Additional Explanation