GB/T 34012-2017   Air cleaner for ventilation system (English Version)
Standard No.: GB/T 34012-2017 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 7000 words Price(USD):150.0 remind me the price change

Email:

Implemented on:2018-6-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 34012-2017
English Name: Air cleaner for ventilation system
Chinese Name: 通风系统用空气净化装置
Chinese Classification: P48    Ventilation and air conditioning engineering
Professional Classification: GB    National Standard
ICS Classification: 91.140.30 91.140.30    Ventilation and air-conditioning systems 91.140.30
Issued by: MOHURD; AQSIQ
Issued on: 2017-07-12
Implemented on: 2018-6-1
Status: valid
Language: English
File Format: PDF
Word Count: 7000 words
Price(USD): 150.0
Delivery: via email in 1 business day
SAC/TC 143 is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by Ministry of Housing and Urban-Rural Development of the People's Republic of China (MOHURD). This standard is under the jurisdiction of SAC/TC 143 National Technical Committee on Heating Ventilating and Air Conditioning of Standardization Administration of China. Air Cleaner for Ventilation System 1 Scope This standard specifies terms and definitions, classification and mark, general requirements, requirements, test methods, inspection rules as well as marking, packaging, transport and storage of air cleaner for ventilation system. This standard is applicable to production and inspection of air cleaner used for ventilation and air conditioning systems. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191 Packaging - Pictorial Marking for Handling of Goods GB/T 1019 General Requirements for the Package of Household and similar Electrical Appliances GB/T 2828.1 Sampling Procedures for Inspection by Attributes - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for Lot-by-lot Inspection GB 4706.1 Household and Similar Electrical Appliances - Safety - Part 1: General Requirements GB 4706.45 Household and Similar Electrical Appliances - Safety - Particular Requirements for Air-cleaning Appliances GB/T 13306 Plates GB/T 13554 High Efficiency Particulate Air Filter GB/T 14295 Air Filters GB/T 18883 Indoor Air Quality Standard GB/T 21087 Air-to-air Energy Recovery Equipment GB 21551.3 Antibacterial and Cleaning Function for Household and Similar Electrical Appliances - Particular Requirements of Air Cleaner GB 50243 Code of Acceptance for Construction Quality of Ventilation and Air Conditioning Works JJG 846 Dust Concentration Measuring Meter WS/T 367 Regulation of Disinfection Technique in Healthcare Settings Ministry of Health P.R China Regulation of Disinfection Technique (2002) 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. 3.1 air cleaner for ventilation system device that is possessed of a certain capacity to remove air pollutants in the air from ventilation system 3.2 air pollutants substance in the air which has harmful influence on human body or environment, including particulate matters, gaseous pollutants, microorganism and other pollutants 3.3 inhalable particulate matter (PM10) particulate matter in ambient air whose aerodynamic equivalent diameter is less than or equal to 10μm 3.4 fine particulate matter (PM2.5) particulate matter in ambient air whose aerodynamic equivalent diameter is less than or equal to 2.5μm 3.5 rated air flow air flow designed to be treated by air cleaner in unit time in the specified state 3.6 cleaning efficiency capacity of air cleaner for removing air pollutant passing the air cleaner by once at rated air flow, i.e. the ratio of the concentration difference between pollutants in the air at inlet and those at outlet of the air cleaner to the concentration of pollutant in the air at inlet 3.7 initial resistance static pressure loss of non-powered air cleaner operating at rated air flow in initial state 3.8 final resistance specified resistance value of air cleaner raised and reached due to standard synthetic dust collection at rated air flow, which is the index used to characterize the performance of isolated non-powered air cleaner 3.9 dust holding capacity total mass of standard synthetic dust collected by air cleaner reaching final resistance at rated air flow, which is the index used to characterize the performance of isolated non-powered air cleaner 3.10 rated power input power of air cleaner working at rated air flow and wind pressure in initial state 3.11 cleaning energy efficiency ratio of clean ventilation quantity to rated power when powered air cleaner operates at rated air flow and wind pressure Note: clean ventilation quantity is the product of rated air flow and cleaning efficiency. 4 Classification and Mark 4.1 Classification 4.1.1 Classified by object it acts on Air cleaner may be classified, by object on which it acts, into particulate matter type, gaseous pollutant type and microorganism type, with the codes of KL, QT and WS respectively. 4.1.2 Classified by cleaning efficiency 4.1.2.1 Air cleaner may be classified by the efficiency for cleaning the particulate matters into Grade A, Grade B, Grade C and Grade D air cleaners, with the efficiency of Grade A air cleaner being highest. 4.1.2.2 Air cleaner may be classified by the efficiency for cleaning the gaseous pollutants into Grade A, Grade B and Grade C air cleaners, with the efficiency of Grade A air cleaner being highest. 4.1.2.3 Air cleaner may be classified by the efficiency for cleaning the microorganism into Grade A, Grade B, Grade C and Grade D air cleaners, with the efficiency of Grade A air cleaner being highest. 4.1.3 Classified by whether it possesses fan Air cleaner may be classified by whether it is with self-contained fan into non-powered and powered air cleaners, with the codes of WD and YD respectively. 4.2 Mark Air cleaner shall be marked as follows: Example 1: Non-powered particulate matter type air cleaner with cleaning efficiency of Grade A and rated air flow of 1,500 m3/h is marked as TKJ-(KL-A)-1500-WD. Example 2: Powered gaseous pollutant type air cleaner with cleaning efficiency of Grade B and rated air flow of 1,000 m3/h is marked as TKJ-(QT-B)-1000-YD. Example 3: Combined non-powered air cleaner with PM cleaning efficiency of Grade A, gaseous pollutant cleaning efficiency of Grade B, microorganism cleaning efficiency of Grade C and rated air flow of 1,500m3/h is marked as TKJ-(KL-A/QT-B/WS-C)-1500-WD. 5 General Requirements 5.1 Basic requirements 5.1.1 As for air cleaner, the rated voltage of single phase shall not be greater than 250 V, the rated voltage of three phases shall not be greater than 480 V and rated frequency shall be 50Hz. 5.1.2 As for air cleaner, power-off protection measures shall be taken to ensure the internal devices are powered off when the device is opened for repair or maintenance. 5.1.3 The electrical shock protection of air cleaner shall meet the relevant requirements of GB 4706.1. 5.1.4 The environmental protection and fireproof performances of air cleaner shall meet the requirements of the environment in which it is used. 5.2 Material Filtering material, binder, sealant, sealing gasket, protective net, frame and the like adopted for air cleaner shall meet the relevant requirements of GB/T 14295 and GB/T 13554. 5.3 Structure 5.3.1 Frame or support shall possess sufficient strength and rigidity and be able to withstand weight and pressure caused by installation, operation or repair. 5.3.2 Sealing shall be carried out between frame and device module as well as between modules. 5.3.3 It shall be convenient to disassemble and assemble the parts of air cleaner which are cleanable and replaceable. 6 Requirements 6.1 Appearance 6.1.1 The surface of air cleaner shall be smooth and clean, without scratch, rust stain, indentation or damage. 6.1.2 The sprayed coating shall be uniform, without flow mark, bubble or scaling. 6.1.3 Parts shall be fastened without looseness; components like filtering material, divider, protective net, etc. shall be free from deformation; sealing gasket shall not get loose. 6.1.4 Frame or support shall not be concavo convex, twisted or damaged, and its appearance shall be intact. 6.1.5 Text as well as graphic symbol mark stating the functions shall be correct, legible, upright and firm. 6.1.6 Electrical safety warning and electric terminal wiring diagram shall be indicated on the device enclosure. 6.2 Cleaning efficiency The efficiency of air cleaner for cleaning air pollutants at rated air flow in initial state shall be in accordance with those specified in Table l, and the measured value shall not be less than 95% of the nominal value.
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Mark 5 General Requirements 6 Requirements 7 Testing Methods 8 Inspection Rules 9 Marking, Packaging, Transport and Storage Annex A (Normative) Test Methods for PM2.5 Cleaning Efficiency Annex B (Informative) Test Methods for PM 2.5 Cleaning Effect of Air Cleaner at Project Site Annex C (Normative) Test Methods for Gaseous Pollutants Cleaning Efficiency Annex D (Normative) Test Method for Microorganism Cleaning Efficiency Annex E (Normative) Test Method for Ozone Concentration Increment and Ultraviolet Leakage Quantity
Referred in GB/T 34012-2017:
*GBT191-1990
*GB/T 1019-2008 General requirements for the package of household and similar electrical appliances
*GB/T 2828.1-2012 Sampling procedures for inspection by attributea-Part1:Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
*GB 4706.1-2005 Household and Similar Electrical Appliances – Safety - Part 1: General Requirements
*GB 4706.45-2008 Household and similar electrical appliances - Safety - Particular requirements for air-cleaning appliances
*GB/T 13306-2011 Plate
*GB/T 13554-2020 High efficiency particulate air filter
*GB/T 14295-2019 Air filter
*GB/T 18883-2022 Standards for indoor air quality
*GB/T 21087-2020 Energy recovery ventilators for outdoor air handling
*GB 21551.3-2010 Antibacterial and cleaning function for household and similar electrical appliances—Particular requirements of air cleaner
*GB 50243-2016 Code of Acceptance for Construction Quality of Ventilation and Air
*JJG 846-2015 Verification Regulation of Dust Concentration Measuring Instruments
*WS/T 367-2012 Regulation of disinfection technique in healthcare settings
GB/T 34012-2017 is referred in:
*GB/T 21087-2020 Energy recovery ventilators for outdoor air handling
*GB/T 26949.15-2017 Industrial trucks-Verification of stability- Part 15:Counterbalanced trucks with articulated steering
*GB/T 12727-2017 Qualification of safety class electrical equipment for nuclear power plants
*GB/T 9711-2017 Petroleum and natural gas industries―Steel pipe for pipeline transportation systems
*GB/T 7809-2017 Rolling bearings―Housings for insert bearings―Boundary dimensions
*GB/T 7932-2017 Pneumatic fluid power. General rules and safety requirements for systems and their components
Code of China
Standard
GB/T 34012-2017  Air cleaner for ventilation system (English Version)
Standard No.GB/T 34012-2017
Statusvalid
LanguageEnglish
File FormatPDF
Word Count7000 words
Price(USD)150.0
Implemented on2018-6-1
Deliveryvia email in 1 business day
Detail of GB/T 34012-2017
Standard No.
GB/T 34012-2017
English Name
Air cleaner for ventilation system
Chinese Name
通风系统用空气净化装置
Chinese Classification
P48
Professional Classification
GB
ICS Classification
Issued by
MOHURD; AQSIQ
Issued on
2017-07-12
Implemented on
2018-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
7000 words
Price(USD)
150.0
Keywords
GB/T 34012-2017, GB 34012-2017, GBT 34012-2017, GB/T34012-2017, GB/T 34012, GB/T34012, GB34012-2017, GB 34012, GB34012, GBT34012-2017, GBT 34012, GBT34012
Introduction of GB/T 34012-2017
SAC/TC 143 is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by Ministry of Housing and Urban-Rural Development of the People's Republic of China (MOHURD). This standard is under the jurisdiction of SAC/TC 143 National Technical Committee on Heating Ventilating and Air Conditioning of Standardization Administration of China. Air Cleaner for Ventilation System 1 Scope This standard specifies terms and definitions, classification and mark, general requirements, requirements, test methods, inspection rules as well as marking, packaging, transport and storage of air cleaner for ventilation system. This standard is applicable to production and inspection of air cleaner used for ventilation and air conditioning systems. 2 Normative References The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191 Packaging - Pictorial Marking for Handling of Goods GB/T 1019 General Requirements for the Package of Household and similar Electrical Appliances GB/T 2828.1 Sampling Procedures for Inspection by Attributes - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for Lot-by-lot Inspection GB 4706.1 Household and Similar Electrical Appliances - Safety - Part 1: General Requirements GB 4706.45 Household and Similar Electrical Appliances - Safety - Particular Requirements for Air-cleaning Appliances GB/T 13306 Plates GB/T 13554 High Efficiency Particulate Air Filter GB/T 14295 Air Filters GB/T 18883 Indoor Air Quality Standard GB/T 21087 Air-to-air Energy Recovery Equipment GB 21551.3 Antibacterial and Cleaning Function for Household and Similar Electrical Appliances - Particular Requirements of Air Cleaner GB 50243 Code of Acceptance for Construction Quality of Ventilation and Air Conditioning Works JJG 846 Dust Concentration Measuring Meter WS/T 367 Regulation of Disinfection Technique in Healthcare Settings Ministry of Health P.R China Regulation of Disinfection Technique (2002) 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. 3.1 air cleaner for ventilation system device that is possessed of a certain capacity to remove air pollutants in the air from ventilation system 3.2 air pollutants substance in the air which has harmful influence on human body or environment, including particulate matters, gaseous pollutants, microorganism and other pollutants 3.3 inhalable particulate matter (PM10) particulate matter in ambient air whose aerodynamic equivalent diameter is less than or equal to 10μm 3.4 fine particulate matter (PM2.5) particulate matter in ambient air whose aerodynamic equivalent diameter is less than or equal to 2.5μm 3.5 rated air flow air flow designed to be treated by air cleaner in unit time in the specified state 3.6 cleaning efficiency capacity of air cleaner for removing air pollutant passing the air cleaner by once at rated air flow, i.e. the ratio of the concentration difference between pollutants in the air at inlet and those at outlet of the air cleaner to the concentration of pollutant in the air at inlet 3.7 initial resistance static pressure loss of non-powered air cleaner operating at rated air flow in initial state 3.8 final resistance specified resistance value of air cleaner raised and reached due to standard synthetic dust collection at rated air flow, which is the index used to characterize the performance of isolated non-powered air cleaner 3.9 dust holding capacity total mass of standard synthetic dust collected by air cleaner reaching final resistance at rated air flow, which is the index used to characterize the performance of isolated non-powered air cleaner 3.10 rated power input power of air cleaner working at rated air flow and wind pressure in initial state 3.11 cleaning energy efficiency ratio of clean ventilation quantity to rated power when powered air cleaner operates at rated air flow and wind pressure Note: clean ventilation quantity is the product of rated air flow and cleaning efficiency. 4 Classification and Mark 4.1 Classification 4.1.1 Classified by object it acts on Air cleaner may be classified, by object on which it acts, into particulate matter type, gaseous pollutant type and microorganism type, with the codes of KL, QT and WS respectively. 4.1.2 Classified by cleaning efficiency 4.1.2.1 Air cleaner may be classified by the efficiency for cleaning the particulate matters into Grade A, Grade B, Grade C and Grade D air cleaners, with the efficiency of Grade A air cleaner being highest. 4.1.2.2 Air cleaner may be classified by the efficiency for cleaning the gaseous pollutants into Grade A, Grade B and Grade C air cleaners, with the efficiency of Grade A air cleaner being highest. 4.1.2.3 Air cleaner may be classified by the efficiency for cleaning the microorganism into Grade A, Grade B, Grade C and Grade D air cleaners, with the efficiency of Grade A air cleaner being highest. 4.1.3 Classified by whether it possesses fan Air cleaner may be classified by whether it is with self-contained fan into non-powered and powered air cleaners, with the codes of WD and YD respectively. 4.2 Mark Air cleaner shall be marked as follows: Example 1: Non-powered particulate matter type air cleaner with cleaning efficiency of Grade A and rated air flow of 1,500 m3/h is marked as TKJ-(KL-A)-1500-WD. Example 2: Powered gaseous pollutant type air cleaner with cleaning efficiency of Grade B and rated air flow of 1,000 m3/h is marked as TKJ-(QT-B)-1000-YD. Example 3: Combined non-powered air cleaner with PM cleaning efficiency of Grade A, gaseous pollutant cleaning efficiency of Grade B, microorganism cleaning efficiency of Grade C and rated air flow of 1,500m3/h is marked as TKJ-(KL-A/QT-B/WS-C)-1500-WD. 5 General Requirements 5.1 Basic requirements 5.1.1 As for air cleaner, the rated voltage of single phase shall not be greater than 250 V, the rated voltage of three phases shall not be greater than 480 V and rated frequency shall be 50Hz. 5.1.2 As for air cleaner, power-off protection measures shall be taken to ensure the internal devices are powered off when the device is opened for repair or maintenance. 5.1.3 The electrical shock protection of air cleaner shall meet the relevant requirements of GB 4706.1. 5.1.4 The environmental protection and fireproof performances of air cleaner shall meet the requirements of the environment in which it is used. 5.2 Material Filtering material, binder, sealant, sealing gasket, protective net, frame and the like adopted for air cleaner shall meet the relevant requirements of GB/T 14295 and GB/T 13554. 5.3 Structure 5.3.1 Frame or support shall possess sufficient strength and rigidity and be able to withstand weight and pressure caused by installation, operation or repair. 5.3.2 Sealing shall be carried out between frame and device module as well as between modules. 5.3.3 It shall be convenient to disassemble and assemble the parts of air cleaner which are cleanable and replaceable. 6 Requirements 6.1 Appearance 6.1.1 The surface of air cleaner shall be smooth and clean, without scratch, rust stain, indentation or damage. 6.1.2 The sprayed coating shall be uniform, without flow mark, bubble or scaling. 6.1.3 Parts shall be fastened without looseness; components like filtering material, divider, protective net, etc. shall be free from deformation; sealing gasket shall not get loose. 6.1.4 Frame or support shall not be concavo convex, twisted or damaged, and its appearance shall be intact. 6.1.5 Text as well as graphic symbol mark stating the functions shall be correct, legible, upright and firm. 6.1.6 Electrical safety warning and electric terminal wiring diagram shall be indicated on the device enclosure. 6.2 Cleaning efficiency The efficiency of air cleaner for cleaning air pollutants at rated air flow in initial state shall be in accordance with those specified in Table l, and the measured value shall not be less than 95% of the nominal value.
Contents of GB/T 34012-2017
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Mark 5 General Requirements 6 Requirements 7 Testing Methods 8 Inspection Rules 9 Marking, Packaging, Transport and Storage Annex A (Normative) Test Methods for PM2.5 Cleaning Efficiency Annex B (Informative) Test Methods for PM 2.5 Cleaning Effect of Air Cleaner at Project Site Annex C (Normative) Test Methods for Gaseous Pollutants Cleaning Efficiency Annex D (Normative) Test Method for Microorganism Cleaning Efficiency Annex E (Normative) Test Method for Ozone Concentration Increment and Ultraviolet Leakage Quantity
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 34012-2017, GB 34012-2017, GBT 34012-2017, GB/T34012-2017, GB/T 34012, GB/T34012, GB34012-2017, GB 34012, GB34012, GBT34012-2017, GBT 34012, GBT34012