GB/T 18883-2022   Standards for indoor air quality (English Version)
Standard No.: GB/T 18883-2022 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 21000 words Price(USD):630.0 remind me the price change

Email:

Implemented on:2023-2-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 18883-2022
English Name: Standards for indoor air quality
Chinese Name: 室内空气质量标准
Chinese Classification: C51    Environmental sanitation
Professional Classification: GB    National Standard
ICS Classification: 13.040.01 13.040.01    Air quality in general 13.040.01
Issued by: SAMR; SAC
Issued on: 2022-07-11
Implemented on: 2023-2-1
Status: valid
Superseding:GB/T 18883-2002 Indoor air quality standard
Language: English
File Format: PDF
Word Count: 21000 words
Price(USD): 630.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This document is developed in accordance with the rules given in GB/T 1.1-2020 Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents. This document replaces GB/T 18883-2002 Indoor air quality standard. In addition to structural adjustments and editorial changes, the following main technical changes have been made with respect to GB/T 18883-2002: a) four terms, i.e., “fine particulate matter”, “1-hour average”, “8-hour average” and “24-hour average”, and their definitions, are added (see 3.3, 3.5~3.7); the term “normal state” and its definition is deleted (see 3.4 of Edition 2002); three terms, i.e., "indoor air quality indicator", "inhalable particulate matter" and "total volatile organic compounds", and their definitions, are modified (see 3.1, 3.2 and 3.4; 3.1~3.3 of Edition 2002); b) three indicators, i.e., trichloroethylene, tetrachloroethylene and fine particulate matter, and their requirements are added (see 4.2); c) the "air flow rate" is changed to "air velocity" (see 4.2; 4.2 of Edition 2002); d) the "air conditioning in summer" and "heating in winter" in remarks on temperature, relative humidity and air velocity are changed to "summer" and "winter" respectively (see 4.2; 4.2 of Edition 2002); e) the "total number of colonies" is changed to "total bacterial count" (see 4.2; 4.2 of Edition 2002); f) the requirements of seven indicators, i.e., nitrogen dioxide, carbon dioxide, formaldehyde, benzene, inhalable particulate matter, total bacterial count and radon, are modified (see 4.2; 4.2 of Edition 2002); g) the radon control requirements are modified, and the "action level" is changed to the "reference level" (see 4.2; 4.2 of Edition 2002); h) technical contents such as environmental requirements, sample transportation and preservation, parallel sample inspection, result expression and laboratory safety are added (see A.2.1, A.7, A.9.4, A.10.2 and A.11 in Annex A); i) the determination methods and method sources of 11 indicators, i.e., temperature, relative humidity, air velocity, fresh air volume, ozone, nitrogen dioxide, sulfur dioxide, carbon dioxide, carbon monoxide, ammonia and formaldehyde (spectrophotometry), are modified; the determination methods and method sources of trichloroethylene, tetrachloroethylene and fine particulate matter are added; the recommended sampling method parameters are added (see Annex A; Annex A of Edition 2002); j) the determination methods of 5 indicators, i.e., formaldehyde (high performance liquid chromatography), benzo[a]pyrene, inhalable particulate matter, fine particulate matter and radon, are added (see Annexes B, E, F and H), and those of benzene, total volatile organic compounds (TVOC) and total bacterial count are modified (see Annexes C, D and G; Annexes B~D of Edition 2002). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights. This document was proposed by and is under the jurisdiction of the National Health Commission of the People's Republic of China. The previous editions of this document are as follows: ——it was firstly released as GB/T 18883-2002 in 2002; ——this is the first revision. Standards for indoor air quality 1 Scope This standard specifies the physical, chemical, biological and radioactive indicators and requirements of indoor air quality, and describes the measurement methods of the indicators. This standard is applicable to residential and office buildings, and may apply to other indoor environment by reference. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 3095–2012 Ambient air quality standard GB/T 12372 Standard method for examination of nitrogen dioxide in air of residential areas-Modified Saltzman method GB/T 14669 Air quality. Determination of ammonia. Ion selective electrode method GB/T 15435 Ambient air - Determination of nitrogen dioxide - Saltzman method GB/T 16128 Standard method for hygienic examination of sulfur dioxide in air of residential areas - Formaldehyde solution sampling-pararosaniline hydrochloride spectrophotometric method GB/T 16129 Standard method for hygienic examination of formaldehyde in air of residential areas - Spectrophotometric method GB/T 18204.1 Examination methods for public places - Part 1: Physical parameters GB/T 18204.2 Examination methods for public places - Part 2: Chemical pollutants GB/T 27476.5 Safety in testing laboratories - Part 5: Chemical aspects GB/T 32465 Requirements for verification & validation of detection methods and internal quality control on chemical analysis HJ 93 Specifications and test procedures for PM10 and PM2.5 sampler HJ/T 167 Technical specification for monitoring of indoor air quality HJ 533 Air and exhaust gas - Determination of ammonia - Nessler’s reagent spectrophotometry HJ 590 Ambient air - Determination of ozone - Ultraviolet photometric method 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB 3095 - 2012 and the following apply. 3.1 indoor air quality indicator physical, chemical, biological and radioactive indicators in indoor air related to human health 3.2 inhalable particulate matter; PM10 particulate matter floating in the air, with particle size (aerodynamic equivalent diameter) less than or equal to 10μm [Source: GB 3095-2012, 3.3, modified] 3.3 fine particulate matter; PM2.5 particulate matter floating in the air, with particle size (aerodynamic equivalent diameter) less than or equal to 2.5μm [Source: GB 3095-2012, 3.4, modified] 3.4 total volatile organic compounds; TVOC volatile organic compounds with retention time between n-hexane and n-hexadecane when sampled by Tenax TA or equivalent filling adsorption tube and analyzed with a non-polar or weak-polar capillary column (polarity index: <10) 3.5 1-hour average arithmetic average of pollutant concentration in any 1 hour [Source: GB/T 3095- 2012, 3.8] 3.6 8-hour average arithmetic average of pollutant concentration in consecutive 8 hours [Source: GB 3095-2012, 3.9, modified] 3.7 24-hour average arithmetic average of pollutant concentration in consecutive 24 hours [Source: GB 3095-2012, 3.10, modified] 4 Requirement for indoor air quality 4.1 Indoor air shall be non-toxic, harmless and have no abnormal smell. 4.2 Indoor air quality indicators and requirements shall comply with the provisions of Table 1.
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Requirement for indoor air quality 5 Determination and evaluation of indoor air quality indicators Annex A (Nominative) Technical guideline for detection of indoor air quality indicators Annex B (Nominative) Determination of formaldehyde Annex C (Normative) Determination of benzene, methylbenzene and xylene Annex D (Normative) Determination of total volatile organic compounds (TVOC) Annex E (Normative) Determination of benzo[a]pyrene in inhalable particulate matter Annex F (Normative) Determination of inhalable particulate matter and fine particulate matter Annex G (Normative) Determination of total bacterial count Annex H (Normative) Determination of radon Bibliography
Referred in GB/T 18883-2022:
*GB 3095-2012/XG1-2018 Ambient air quality standard,includes Amendment 1
*GB/T 14669-1993 Air quality - Determination of ammonia - Ion selective electrode method
*GB/T 15435-1995 Ambient air-Determination of nitrogen dioxide-Saltzman method
*GB/T 16128-1995 standard method for hygienic examination of sulfur dioxide in air of residential areas-Formaldehyde solution sampling-pararosaniline hydrochloride spectrophotometric method
*GB/T 16129-1995 STANDARD method for hygienic examination of formaldehyde in air of residential areas-Spectrophotometric method
*GB/T 18204.1-2013 Examination methods for public places - Part 1: Physical parameters
*GB/T 18204.2-2014 Examination methods for public places—Part 2:Chemical pollutants
*GB/T 27476.5-2014 Safety in testing laboratories-Part 5:Chemical aspects
*GB/T 32465-2015 Requirements for verification & validation of detection methods and internal quality control on chemical analysis
*HJ 93-2013/XG1-2018 Specifications and Test Procedures for PM10 and PM2.5 Sampler , includes Amendment 1
*HJ/T 167-2004 Technical specification for monitoring of indoor air quality
*HJ 533-2009 Air and exhaust gas - Determination of ammonia - Nessler's reagent spectrophotometry
*HJ 590-2010/XG1-2018 Ambient air-Dtermination of ozone-Ultraviolet photometric method , includes Amendment 1
*GB/T 18204.3-2013 Examination Methods for Public Places - Part 3: Airborne Microorganism
*GBZ/T 182-2006 Specifications for monitoring of indoor radon and its decay products
*HJ 583-2010 Ambient air—Determination of benzene and its analogies using sorbent adsorption thermal desorption and Gas Chromatography
*HJ 584-2010 Ambient air—Determination of benzene and its analogies by activated charcoal adsorption carbon disulfide desorption and gas chromatography
*HJ 618-2011/XG1-2018 Determination of atmospheric articles PM10 and PM2.5 in ambient air by gravimetric method , includes Amendment 1
*HJ 647-2013 Ambient air and stationary source emissions - Determination of gas and particle-phase polycyclic aromatic hydrocarbons - High performance liquid chromatography
*HJ 683-2014 Ambient air-Determination of aldehyde and ketone compounds-High performance liquid chromatography
*HJ 956-2018 Ambient air - Determination of benzo[a]pyrene - High performance liquid chromatography
*HJ 1212-2021 Measurement methods for determination of radon in environmental air
GB/T 18883-2022 is referred in:
*GB 50174-2017 Code for design of electronic information systern room
*GB/T 18801-2022 Air cleaner
*GB/T 50378-2019 Assessment standard for green building
*GB/T 34012-2017 Air cleaner for ventilation system
*GB/T 18801-2015 Air Cleaner
*YY 0783-2010 Medical electrical equipment—Part 2-34:Particular requirements for the safety,including essential performance,of invasive blood pressure monitoring equipments
*FZ/T 73013-1998 Knitted swiming suits
*GB/T 18386-2001 Electric vehicles-Reference energy consumption and range-Test procedures
*GB 50174-2017-TWSM Explanation of Provisions of Code for Design of Data Centers
*GB/T 50378-2014 Assessment Standard for Green Building
*T/CEA 0054-2024 Evaluation requirements of green product —Traction lift
*JGJ/T 67-2019 Standard for design of office building
*GB/T 17988-2024 Performance requirement and test method for disinfecting tableware cabinet
*GB/T 21551.6-2024 Antimicrobial and cleaning function of household and similar electrical appliances—Part 6:Particular requirements for air conditioner
*GB/T 21551.1-2024 Antimicrobial and cleaning function of household and similar electrical appliances—Part 1:General requirement
*GB/T 21551.4-2024 Antimicrobial and cleaning function of household and similar electrical appliances—Part 4:Particular requirements for refrigerator
*GB/T 21551.3-2024 Antimicrobial and cleaning function of household and similar electrical appliances—Part 3 : Particular requirements for air cleaner
*GB/T 17216-2025 Hygienic requirement for peacetime utilization of civil air defence works
*GB/T 9981-2025 Hygienic specification for rural residential buildings
Code of China
Standard
GB/T 18883-2022  Standards for indoor air quality (English Version)
Standard No.GB/T 18883-2022
Statusvalid
LanguageEnglish
File FormatPDF
Word Count21000 words
Price(USD)630.0
Implemented on2023-2-1
Deliveryvia email in 1 business day
Detail of GB/T 18883-2022
Standard No.
GB/T 18883-2022
English Name
Standards for indoor air quality
Chinese Name
室内空气质量标准
Chinese Classification
C51
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2022-07-11
Implemented on
2023-2-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 18883-2002 Indoor air quality standard
Language
English
File Format
PDF
Word Count
21000 words
Price(USD)
630.0
Keywords
GB/T 18883-2022, GB 18883-2022, GBT 18883-2022, GB/T18883-2022, GB/T 18883, GB/T18883, GB18883-2022, GB 18883, GB18883, GBT18883-2022, GBT 18883, GBT18883
Introduction of GB/T 18883-2022
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This document is developed in accordance with the rules given in GB/T 1.1-2020 Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents. This document replaces GB/T 18883-2002 Indoor air quality standard. In addition to structural adjustments and editorial changes, the following main technical changes have been made with respect to GB/T 18883-2002: a) four terms, i.e., “fine particulate matter”, “1-hour average”, “8-hour average” and “24-hour average”, and their definitions, are added (see 3.3, 3.5~3.7); the term “normal state” and its definition is deleted (see 3.4 of Edition 2002); three terms, i.e., "indoor air quality indicator", "inhalable particulate matter" and "total volatile organic compounds", and their definitions, are modified (see 3.1, 3.2 and 3.4; 3.1~3.3 of Edition 2002); b) three indicators, i.e., trichloroethylene, tetrachloroethylene and fine particulate matter, and their requirements are added (see 4.2); c) the "air flow rate" is changed to "air velocity" (see 4.2; 4.2 of Edition 2002); d) the "air conditioning in summer" and "heating in winter" in remarks on temperature, relative humidity and air velocity are changed to "summer" and "winter" respectively (see 4.2; 4.2 of Edition 2002); e) the "total number of colonies" is changed to "total bacterial count" (see 4.2; 4.2 of Edition 2002); f) the requirements of seven indicators, i.e., nitrogen dioxide, carbon dioxide, formaldehyde, benzene, inhalable particulate matter, total bacterial count and radon, are modified (see 4.2; 4.2 of Edition 2002); g) the radon control requirements are modified, and the "action level" is changed to the "reference level" (see 4.2; 4.2 of Edition 2002); h) technical contents such as environmental requirements, sample transportation and preservation, parallel sample inspection, result expression and laboratory safety are added (see A.2.1, A.7, A.9.4, A.10.2 and A.11 in Annex A); i) the determination methods and method sources of 11 indicators, i.e., temperature, relative humidity, air velocity, fresh air volume, ozone, nitrogen dioxide, sulfur dioxide, carbon dioxide, carbon monoxide, ammonia and formaldehyde (spectrophotometry), are modified; the determination methods and method sources of trichloroethylene, tetrachloroethylene and fine particulate matter are added; the recommended sampling method parameters are added (see Annex A; Annex A of Edition 2002); j) the determination methods of 5 indicators, i.e., formaldehyde (high performance liquid chromatography), benzo[a]pyrene, inhalable particulate matter, fine particulate matter and radon, are added (see Annexes B, E, F and H), and those of benzene, total volatile organic compounds (TVOC) and total bacterial count are modified (see Annexes C, D and G; Annexes B~D of Edition 2002). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights. This document was proposed by and is under the jurisdiction of the National Health Commission of the People's Republic of China. The previous editions of this document are as follows: ——it was firstly released as GB/T 18883-2002 in 2002; ——this is the first revision. Standards for indoor air quality 1 Scope This standard specifies the physical, chemical, biological and radioactive indicators and requirements of indoor air quality, and describes the measurement methods of the indicators. This standard is applicable to residential and office buildings, and may apply to other indoor environment by reference. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 3095–2012 Ambient air quality standard GB/T 12372 Standard method for examination of nitrogen dioxide in air of residential areas-Modified Saltzman method GB/T 14669 Air quality. Determination of ammonia. Ion selective electrode method GB/T 15435 Ambient air - Determination of nitrogen dioxide - Saltzman method GB/T 16128 Standard method for hygienic examination of sulfur dioxide in air of residential areas - Formaldehyde solution sampling-pararosaniline hydrochloride spectrophotometric method GB/T 16129 Standard method for hygienic examination of formaldehyde in air of residential areas - Spectrophotometric method GB/T 18204.1 Examination methods for public places - Part 1: Physical parameters GB/T 18204.2 Examination methods for public places - Part 2: Chemical pollutants GB/T 27476.5 Safety in testing laboratories - Part 5: Chemical aspects GB/T 32465 Requirements for verification & validation of detection methods and internal quality control on chemical analysis HJ 93 Specifications and test procedures for PM10 and PM2.5 sampler HJ/T 167 Technical specification for monitoring of indoor air quality HJ 533 Air and exhaust gas - Determination of ammonia - Nessler’s reagent spectrophotometry HJ 590 Ambient air - Determination of ozone - Ultraviolet photometric method 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB 3095 - 2012 and the following apply. 3.1 indoor air quality indicator physical, chemical, biological and radioactive indicators in indoor air related to human health 3.2 inhalable particulate matter; PM10 particulate matter floating in the air, with particle size (aerodynamic equivalent diameter) less than or equal to 10μm [Source: GB 3095-2012, 3.3, modified] 3.3 fine particulate matter; PM2.5 particulate matter floating in the air, with particle size (aerodynamic equivalent diameter) less than or equal to 2.5μm [Source: GB 3095-2012, 3.4, modified] 3.4 total volatile organic compounds; TVOC volatile organic compounds with retention time between n-hexane and n-hexadecane when sampled by Tenax TA or equivalent filling adsorption tube and analyzed with a non-polar or weak-polar capillary column (polarity index: <10) 3.5 1-hour average arithmetic average of pollutant concentration in any 1 hour [Source: GB/T 3095- 2012, 3.8] 3.6 8-hour average arithmetic average of pollutant concentration in consecutive 8 hours [Source: GB 3095-2012, 3.9, modified] 3.7 24-hour average arithmetic average of pollutant concentration in consecutive 24 hours [Source: GB 3095-2012, 3.10, modified] 4 Requirement for indoor air quality 4.1 Indoor air shall be non-toxic, harmless and have no abnormal smell. 4.2 Indoor air quality indicators and requirements shall comply with the provisions of Table 1.
Contents of GB/T 18883-2022
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Requirement for indoor air quality 5 Determination and evaluation of indoor air quality indicators Annex A (Nominative) Technical guideline for detection of indoor air quality indicators Annex B (Nominative) Determination of formaldehyde Annex C (Normative) Determination of benzene, methylbenzene and xylene Annex D (Normative) Determination of total volatile organic compounds (TVOC) Annex E (Normative) Determination of benzo[a]pyrene in inhalable particulate matter Annex F (Normative) Determination of inhalable particulate matter and fine particulate matter Annex G (Normative) Determination of total bacterial count Annex H (Normative) Determination of radon Bibliography