2025-6-23 18.97.14.83
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 36488-2018
GB/T 36488-2018   Determination of polycyclic aromatic hydrocarbons in coatings (English Version)
Standard No.: GB/T 36488-2018 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 5500 words Price(USD):160.0 remind me the price change

Email:

Implemented on:2019-2-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 36488-2018
English Name: Determination of polycyclic aromatic hydrocarbons in coatings
Chinese Name: 涂料中多环芳烃的测定
Chinese Classification: G50    Basic standard and general method for coating
Professional Classification: GB    National Standard
Issued by: SAMR; SAC
Issued on: 2018-07-13
Implemented on: 2019-2-1
Status: valid
Language: English
File Format: PDF
Word Count: 5500 words
Price(USD): 160.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the China Petroleum and Chemical Industry Association. This standard is under the jurisdiction of National Technical Committee 5 on Paints & Pigments of Standardization Administration of China (SAC/TC 5). Determination of polycyclic aromatic hydrocarbons in coatings Warning: Users of this standard shall be experienced in normal laboratory practicing. This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to adopt appropriate safety and health measures and to ensure compliance with any national regulatory conditions. 1 Scope This standard specifies the terms and definitions, principles, reagents and materials, apparatus, samples, test procedures, test data processing, precision and test reports for the determination of polycyclic aromatic hydrocarbons in coatings by gas chromatography-mass spectrometry. This standard is applicable to the determination of polycyclic aromatic hydrocarbons in coatings and coating films, including but not limited to the polycyclic aromatic hydrocarbons listed in Table A.1 of Annex A. This standard can also be used as a reference in the determination of polycyclic aromatic hydrocarbons in raw materials for coatings. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 3186 Paints, varnishes and raw materials for paints and varnishes—Sampling GB/T 12806 Laboratory glassware—One-mark volumetric flasks 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply. 3.1 polycyclic aromatic hydrocarbons; PAHs a series of hydrocarbon compounds and their derivatives fused by two or more benzene rings which may also have short alkyl or naphthenic substituents   4 Principle The polycyclic aromatic hydrocarbons (PAHs) are extracted from samples by ultrasonic extraction with n-hexane as extraction solvent. The extraction solution is determined by the gas chromatograph-mass spectrometer (GC/MS) and quantified by external standard method. Note: Other approved suitable solvents may also apply. 5 Reagents and materials Unless otherwise specified, only reagents confirmed to be analytical grade and above are used in the analysis. 5.1 N-hexane: chromatographically pure. 5.2 The calibration compounds of PAHs (see Table A.1): the mass fraction shall not be less than 99%. 5.3 Mix standard stock solution: about 200μg/mL. Weigh about 0.02 g of each calibration compound of PAHs (5.2), accurate to 0.1 mg, put it in a 100 mL volumetric flask (6.6), and dilute it to the scale with n-hexane (5.1). Keep the standard stock solution under 4 °C in dark place for 3 months. Note: The certified PAHs mixed standard solution with known concentration may also be used directly. 5.4 Helium: with purity greater than 99.999%. 6 Apparatus 6.1 Gas chromatograph-mass spectrometer (GC/MS): equipped with EI source. 6.2 Ultrasonic generator: with power ≥500 W. 6.3 Centrifuge: with the rotating speed of 3 000 r/min ~ 6 000 r/min, and the chamber temperature of not exceed 40°C during operation. 6.4 Balance: with an accuracy of 0.1 mg. 6.5 Sample bottle: with the capacity of about 15 mL, provided with sealable bottle cover. 6.6 Volumetric flask: brown, with a capacity of 25 mL and 100 mL, at Grade A of GB/T 12806.
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Principle 5 Reagents and materials 6 Apparatus 7 Samples 8 Test procedures 9 Test data processing 10 Precision 11 Test report Annex A (Informative) List of 16 PAHs Annex B (Informative) Reference conditions for determination of 16 PAHs by gas chromatography-mass spectrometry
Referred in GB/T 36488-2018:
*GB/T 3186-2006 Paints varnishes and raw materials for paints and varnishes - Sampling
*GB/T 12806-2011 Laboratory glassware—One-mark volumetric flasks
*GB 4943.1-2011 Information technology equipment -Safety - Part 1: General requirements
*FZ/T 73020-2012 Knitted Casual Wear
*GB/T 14048.5-2017 Low-voltage switchgear and controlgear-Part 5-1:Control circuit devices and switching element-Electromechanical control circuit devices
*GB 4706.1-2005 Household and Similar Electrical Appliances – Safety - Part 1: General Requirements
*QB/T 1333-2018 Handbag and Knapsack
*GB 5749-2022 Standards for drinking water quality
*GB 150-2011 Pressure Vessels (Collection GB150.1~150.4-2011)
*QB/T 1333-2018 Handbag and Knapsack
*GB 17625.1-2022 Electromagnetic compatibility—Limits—Part 1: Limits for harmonic current emissions (equipment input current ≤ 16A per phase)
*TSG 21-2016/XG1-2020 Supervision Regulation on Safety Technology for Stationary Pressure Vessel,includes Amendment 1
*GB 14748-2006 Safety Requirements for Wheeled Child Conveyances
*GB/T 35590-2017 Information technology―General specification for portable digital equipments used power bank
*GB 3565-2005 Safety requirements for bicycles
*GB/T 3077-2015 Alloy structure steels
*GB/T 19001-2016 Quality management systems―Requirements
*GB/T 699-2015 Quality carbon structural steels
GB/T 36488-2018 is referred in:
*GB 30981-2020 Limit of harmful substances of industrial protective coatings
*GB 18581-2020 Limit of harmful substances of woodware coatings
*GB/T 3287-2024 Malleable cast iron pipe fittings
Code of China
Standard
GB/T 36488-2018  Determination of polycyclic aromatic hydrocarbons in coatings (English Version)
Standard No.GB/T 36488-2018
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5500 words
Price(USD)160.0
Implemented on2019-2-1
Deliveryvia email in 1 business day
Detail of GB/T 36488-2018
Standard No.
GB/T 36488-2018
English Name
Determination of polycyclic aromatic hydrocarbons in coatings
Chinese Name
涂料中多环芳烃的测定
Chinese Classification
G50
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2018-07-13
Implemented on
2019-2-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
5500 words
Price(USD)
160.0
Keywords
GB/T 36488-2018, GB 36488-2018, GBT 36488-2018, GB/T36488-2018, GB/T 36488, GB/T36488, GB36488-2018, GB 36488, GB36488, GBT36488-2018, GBT 36488, GBT36488
Introduction of GB/T 36488-2018
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard is developed in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the China Petroleum and Chemical Industry Association. This standard is under the jurisdiction of National Technical Committee 5 on Paints & Pigments of Standardization Administration of China (SAC/TC 5). Determination of polycyclic aromatic hydrocarbons in coatings Warning: Users of this standard shall be experienced in normal laboratory practicing. This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to adopt appropriate safety and health measures and to ensure compliance with any national regulatory conditions. 1 Scope This standard specifies the terms and definitions, principles, reagents and materials, apparatus, samples, test procedures, test data processing, precision and test reports for the determination of polycyclic aromatic hydrocarbons in coatings by gas chromatography-mass spectrometry. This standard is applicable to the determination of polycyclic aromatic hydrocarbons in coatings and coating films, including but not limited to the polycyclic aromatic hydrocarbons listed in Table A.1 of Annex A. This standard can also be used as a reference in the determination of polycyclic aromatic hydrocarbons in raw materials for coatings. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 3186 Paints, varnishes and raw materials for paints and varnishes—Sampling GB/T 12806 Laboratory glassware—One-mark volumetric flasks 3 Terms and definitions For the purposes of this standard, the following terms and definitions apply. 3.1 polycyclic aromatic hydrocarbons; PAHs a series of hydrocarbon compounds and their derivatives fused by two or more benzene rings which may also have short alkyl or naphthenic substituents   4 Principle The polycyclic aromatic hydrocarbons (PAHs) are extracted from samples by ultrasonic extraction with n-hexane as extraction solvent. The extraction solution is determined by the gas chromatograph-mass spectrometer (GC/MS) and quantified by external standard method. Note: Other approved suitable solvents may also apply. 5 Reagents and materials Unless otherwise specified, only reagents confirmed to be analytical grade and above are used in the analysis. 5.1 N-hexane: chromatographically pure. 5.2 The calibration compounds of PAHs (see Table A.1): the mass fraction shall not be less than 99%. 5.3 Mix standard stock solution: about 200μg/mL. Weigh about 0.02 g of each calibration compound of PAHs (5.2), accurate to 0.1 mg, put it in a 100 mL volumetric flask (6.6), and dilute it to the scale with n-hexane (5.1). Keep the standard stock solution under 4 °C in dark place for 3 months. Note: The certified PAHs mixed standard solution with known concentration may also be used directly. 5.4 Helium: with purity greater than 99.999%. 6 Apparatus 6.1 Gas chromatograph-mass spectrometer (GC/MS): equipped with EI source. 6.2 Ultrasonic generator: with power ≥500 W. 6.3 Centrifuge: with the rotating speed of 3 000 r/min ~ 6 000 r/min, and the chamber temperature of not exceed 40°C during operation. 6.4 Balance: with an accuracy of 0.1 mg. 6.5 Sample bottle: with the capacity of about 15 mL, provided with sealable bottle cover. 6.6 Volumetric flask: brown, with a capacity of 25 mL and 100 mL, at Grade A of GB/T 12806.
Contents of GB/T 36488-2018
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Principle 5 Reagents and materials 6 Apparatus 7 Samples 8 Test procedures 9 Test data processing 10 Precision 11 Test report Annex A (Informative) List of 16 PAHs Annex B (Informative) Reference conditions for determination of 16 PAHs by gas chromatography-mass spectrometry
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 36488-2018, GB 36488-2018, GBT 36488-2018, GB/T36488-2018, GB/T 36488, GB/T36488, GB36488-2018, GB 36488, GB36488, GBT36488-2018, GBT 36488, GBT36488