2025-7-15 18.97.14.89
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/YY/T 0597-2006
YY/T 0597-2006   Clip Applicator (English Version)
Standard No.: YY/T 0597-2006 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 4500 words Price(USD):130.0 remind me the price change

Email:

Implemented on:2007-5-1 Delivery: via email in 1 business day
,,
Standard No.: YY/T 0597-2006
English Name: Clip Applicator
Chinese Name: 施夹钳
Chinese Classification: C31    General and microsurgical devices
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.040.40 11.040.40    Implants for surgery, prosthetics and orthotics 11.040.40
Issued by: SFDA
Issued on: 2006-6-19
Implemented on: 2007-5-1
Status: valid
Superseding:YY 0079.3-1992 Implants for surgery -- Metallic clip
Language: English
File Format: PDF
Word Count: 4500 words
Price(USD): 130.0
Delivery: via email in 1 business day
YY/T 0597-2006 Clip applicator 1 Scope This standard specifies the types, basic dimensions, materials, requirements, test methods, inspection rules, as well as markings, packaging, transportation and storage for clip applicator. This standard is applicable to surgical clip applicator. This product is used for clamping metal clips. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments (excluding corrections) to, or revisions, of any of these publications do not apply. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition applies. GB/T 230.1 Metallic rockwell hardness test - Part 1:Test method (scales A, B, C, D, E, F, G, H, K, N, T) (GB/T 230.1-2004, ISO 6508.1:1999, MOD) GB/T 1220 Stainless steel bars (GB/T 1220-1992, neq JIS G4303:1988) GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection (GB/T 2828.1-2003, ISO 2859-1:1999, IDT) GB/T 2829 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability) GB/T 14975 Stainless steel seamless tubes for structures YY 0031-1990 Peritoneal dialysis catheters YY 0079-2006 Implants for surgery - Metallic clip YY/T 0149 Medical instruments of stainless steel - Test methods of corrosion resistance (YY/T 0149-2006, ISO 13402:1995, MOD) YY 0167-2005 Non-absorbable surgical suture YY/T 1052 Marking requirements for surgical instruments 3 Types, basic dimensions, materials 3.1 The type and basic dimensions of the clip applicator shall meet those specified in Figure 1, Figure 2, and Table 1. 3.2 The parts of clip applicator such as the forceps jaws, stem, or handle that come into contact with the human body shall be made of stainless steel materials such as 1Cr18Ni9Ti, 1Cr13, 2Cr13, and 3Cr13 as specified in GB/T 1220 and GB/T 14975.
Foreword i 1 Scope 2 Normative references 3 Types, basic dimensions, materials 4 Requirements 5 Test method 6 Inspection rules 7 Marking 8 Packaging, transportation and storage
Referred in YY/T 0597-2006:
*GB/T 230.1-2018 Metallic materials—Rockwell hardness test—Part 1:Test method
*GB/T 1220-2007 Stainless steel bars
*GB/T 2828.1-2012 Sampling procedures for inspection by attributea-Part1:Sampling schemes indexed by acceptance quality limit(AQL) for lot-by-lot inspection
*GB/T 2829-2002 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability)
*GB/T 14975-2012 Seamless stainless steel tubes for structure
*YY 0031-1990 Peritoneal dialysis catheters
*YY0079-2006
*YY/T 0149-2006 Medical instruments of stainless steel - Test methods of corrosion resistance
*YY 0167-2005 Non-absorbable surgical suture
*YY/T 1052-2004 Marking requirements for surgical instruments
YY/T 0597-2006 is referred in:
*YY/T 0079-2006 Implants for surgery -- Metallic clip
*YY/T 0079-2016 Metallic clip
Code of China
Standard
YY/T 0597-2006  Clip Applicator (English Version)
Standard No.YY/T 0597-2006
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4500 words
Price(USD)130.0
Implemented on2007-5-1
Deliveryvia email in 1 business day
Detail of YY/T 0597-2006
Standard No.
YY/T 0597-2006
English Name
Clip Applicator
Chinese Name
施夹钳
Chinese Classification
C31
Professional Classification
YY
ICS Classification
Issued by
SFDA
Issued on
2006-6-19
Implemented on
2007-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
YY 0079.3-1992 Implants for surgery -- Metallic clip
Language
English
File Format
PDF
Word Count
4500 words
Price(USD)
130.0
Keywords
YY/T 0597-2006, YY 0597-2006, YYT 0597-2006, YY/T0597-2006, YY/T 0597, YY/T0597, YY0597-2006, YY 0597, YY0597, YYT0597-2006, YYT 0597, YYT0597
Introduction of YY/T 0597-2006
YY/T 0597-2006 Clip applicator 1 Scope This standard specifies the types, basic dimensions, materials, requirements, test methods, inspection rules, as well as markings, packaging, transportation and storage for clip applicator. This standard is applicable to surgical clip applicator. This product is used for clamping metal clips. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments (excluding corrections) to, or revisions, of any of these publications do not apply. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition applies. GB/T 230.1 Metallic rockwell hardness test - Part 1:Test method (scales A, B, C, D, E, F, G, H, K, N, T) (GB/T 230.1-2004, ISO 6508.1:1999, MOD) GB/T 1220 Stainless steel bars (GB/T 1220-1992, neq JIS G4303:1988) GB/T 2828.1 Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection (GB/T 2828.1-2003, ISO 2859-1:1999, IDT) GB/T 2829 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability) GB/T 14975 Stainless steel seamless tubes for structures YY 0031-1990 Peritoneal dialysis catheters YY 0079-2006 Implants for surgery - Metallic clip YY/T 0149 Medical instruments of stainless steel - Test methods of corrosion resistance (YY/T 0149-2006, ISO 13402:1995, MOD) YY 0167-2005 Non-absorbable surgical suture YY/T 1052 Marking requirements for surgical instruments 3 Types, basic dimensions, materials 3.1 The type and basic dimensions of the clip applicator shall meet those specified in Figure 1, Figure 2, and Table 1. 3.2 The parts of clip applicator such as the forceps jaws, stem, or handle that come into contact with the human body shall be made of stainless steel materials such as 1Cr18Ni9Ti, 1Cr13, 2Cr13, and 3Cr13 as specified in GB/T 1220 and GB/T 14975.
Contents of YY/T 0597-2006
Foreword i 1 Scope 2 Normative references 3 Types, basic dimensions, materials 4 Requirements 5 Test method 6 Inspection rules 7 Marking 8 Packaging, transportation and storage
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
YY/T 0597-2006, YY 0597-2006, YYT 0597-2006, YY/T0597-2006, YY/T 0597, YY/T0597, YY0597-2006, YY 0597, YY0597, YYT0597-2006, YYT 0597, YYT0597