2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 31604.27-2016
GB 31604.27-2016   National Food Safety Standard - Food Contact Materials and Articles -Determination of Ethylene Oxide and Propylene Oxide in Plastics (English Version)
Standard No.: GB 31604.27-2016 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5000 words Translation Price(USD):80.0 remind me the price change

Email:

Implemented on:2017-4-19 Delivery: via email in 1 business day

→ → →

,,2017-4-19,7BF81DB7DD882F831479882834033
Standard No.: GB 31604.27-2016
English Name: National Food Safety Standard - Food Contact Materials and Articles -Determination of Ethylene Oxide and Propylene Oxide in Plastics
Chinese Name: 食品安全国家标准 食品接触材料及制品 塑料中环氧乙烷和环氧丙烷的测定
Professional Classification: GB    National Standard
Source Content Issued by: National Health and Family Planning Commission
Issued on: 2016-10-19
Implemented on: 2017-4-19
Status: valid
Superseding:GB/T 23296.11-2009 GB/T 23296.11-2009
Target Language: English
File Format: PDF
Word Count: 5000 words
Translation Price(USD): 80.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard replaces GB/T 23296.11-2009 Food Contact Materials - Determination of Ethylene Oxide and Propylene Oxide in Plastics - Gas Chromatography. The following main changes have been made with respect to GB/T 23296.11-2009 (the previous edition): ——This standard is renamed as National Food Safety Standard - Food Contact Materials and Articles - Determination of Ethylene Oxide and Propylene Oxide in Plastics; ——"Headspace gas chromatography-mass spectrometry" for determination of ethylene oxide and propylene oxide is added. National Food Safety Standard Food Contact Materials and Articles Determination of Ethylene Oxide and Propylene Oxide in Plastics 1 Scope This standard specifies determination method of ethylene oxide and propylene oxide in food contact materials and articles. This standard is applicable to determination of ethylene oxide and propylene oxide in plastic food contact materials and articles. Method I Headspace Gas chromatography-mass Spectrometry 2 Principle Extract ethylene oxide or propylene oxide in the sample with N, N-dimethyl acetamide (DMAC), conduct headspace sample injection, separate ethylene oxide or propylene oxide and ethyl ether (internal standard) and other components in chromatographic column, examine by mass spectrometry detector and carry out quantative determination by internal standard method. 3 Reagents and Materials Unless otherwise specified, analytically-pure reagents and Class-I water (defined in GB/T 6682) are adopted for the purpose of this method. 3.1 Reagents N,N-dimethyl acetamide (DMAC for short, C4H9NO, CAS No.: 127-19-5): chromatographically pure, peak area of impurity with the same retention time as ethylene oxide or propylene oxide in chromatogram shall not exceed 1%. 3.2 Standard product 3.2.1 Ethylene oxide (C2H4O, CAS No.: 75-21-8): with purity ≥99%, or reference material approved and awarded with reference material certificate by the State. 3.2.2 Propylene oxide(C3H6O, No.: 200-879-2): with purity ≥99%, or reference material approved and awarded with reference material certificate by the State. 3.2.3 Ethyl ether (C4H10O, CAS No.: 60-29-7): with purity≥99.5%, or reference material approved and awarded with reference material certificate by the State. Peak area of impurity with the same retention time as ethylene oxide or propylene oxide shall not exceed 1%. 3.3 Preparation of standard solution 3.3.1 Ethylene oxide standard stock solution Weigh 50 mg (accurate to 0.0001 g) ethylene oxide, dissolve with DMAC, scale the volume to 50mL and prepare into stock solution with concentration of 1 mg/mL. Seal preserve in dark place at 4℃, with the valid period of 2 months. 3.3.2 Propylene oxide standard stock solution Weigh 50 mg (accurate to 0.0001 g) propylene oxide, dissolve with DMAC, scale the volume to 50 mL and prepare into stock solution with concentration of 1 mg/mL. The storage conditions of the solution are as specified in 3.3.1. 3.3.3 Ethylene oxide and propylene oxide mixed standard intermediate solution Measure 5 mL DMAC into 50 mL volumetric flask, respectively pipet 2.0 mL ethylene oxide standard stock solution (3.3.1) and 1.0 mL propylene oxide standard stock solution (3.3.2) into the volumetric flask, scale the volume with DMAC and obtain ethylene oxide and propylene oxide mixed standard intermediate solution. In the solution, concentrations of ethylene oxide and propylene oxide are 40.0 μg/mL and 20.0 μg/mL respectively. The storage conditions of the solution are as specified in 3.3.1. 3.3.4 Ethylene oxide and propylene oxide mixed standard solution Pipet 5.0 mL DMAC into six 10 mL volumetric flasks respectively with graduated pipette, respectively pipet 25 μL, 50 μL, 100 μL, 250 μL, 500 μL and 1,000 μL ethylene oxide and propylene oxide mixed standard intermediate solution (3.3.3) into these six volumetric flasks with microinjector and scale the volume with DMAC. The concentrations of ethylene oxide are 0.1 μg/mL, 0.2 μg/mL, 0.4 μg/mL, 1.0 μg/mL, 2.0 μg/mL and 4.0 μg/mL, and those of propylene oxide are 0.05 μg/mL, 0.1 μg/mL, 0.2 μg/mL, 0.5 μg/mL, 1.0 μg/mL and 2.0 μg/mL. The storage conditions of the solution are as specified in 3.3.1. 3.3.5 Ethyl ether internal standard stock solution Weigh 50 mg (accurate to 0.0001 g) ethyl ether into 50 mL volumetric flask containing 5 mL DMAC, scale the volume with DMAC and prepare into stock solution with concentration of 1 mg/mL. The storage conditions of the solution are as specified in 3.3.1. 3.3.6 Ethyl ether internal standard intermediate solution Measure 5 mL DMAC into 10 mL volumetric flask, pipet 2.5 mL ethyl ether internal standard stock solution (3.3.5) into the volumetric flask with graduated pipette, scale the volume with DMAC and obtain ethyl ether internal standard intermediate solution. The concentration of this solution is 250.0 μg/mL. The storage conditions of the solution are as specified in 3.3.1. 4 Instruments and Apparatus 4.1 Gas chromatography - mass spectrometer: equipped with electron bombardment ion source (EI) and headspace automatic sample injector. 4.2 Microinjector: 10 μL, 100μL and 1,000 μL. 4.3 Headspace bottle: 20mL; equipped with aluminium cap and butyl rubber or silicone resin rubber isolation pad whose side contacting sample shall be coated with polytetrafluoroethylene. 4.4 Analytical balance: with sensibility of 0.0001g . 4.5 Mechanical oscillator. 5 Analysis Steps 5.1 Specimen treatment As for specimens that can be dissolved in DMAC, directly weigh them; as for specimens that are not dissolved in DMAC, weigh them as early as possible after crushing them into fragments with particle size less than 1 mm× 1mm with freezing grinder or scissor or other cutting tools and they cannot be heated or softened during cutting. 5.2 Preparation of specimen solution Weigh 1.0 g±0.1 g specimen (5.1) into headspace bottle, pipet 5.0 mL DMAC into the headspace bottle with graduated pipette, add 10 μL ethyl ether internal standard intermediate solution (3.3.6) with microinjector and seal with cap as early as possible. Oscillate headspace bottle with oscillator at frequency of one time every two seconds till specimen dissolution as for specimen that can be dissolved in DMAC and 4 h for DMAC that is not dissolved in DMAC. If sample concentration exceeds linear range, properly dilute the sample with DMAC before adding internal standard solution to make its concentration within the linear range.
Foreword i 1 Scope 2 Principle 3 Reagents and Materials 4 Instruments and Apparatus 5 Analysis Steps 6 Expression of Analysis Result 7 Accuracy 8 Other 9 Principle 10 Reagents and Materials 11 Instruments and Apparatus 12 Analysis Steps 13 Expression of Analysis Result 14 Accuracy 15 Other Annex A Standard Chromatogram of Ethylene Oxide and Propylene Oxide
Referred in GB 31604.27-2016:
*GB 31604.18-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of Migration of Acrylamide
*GB 31604.48-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of Formaldehyde Migration
*GB 31604.40-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Migration of Maleic Acid and Its Acid Anhydride
*GB 31604.44-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Migration of Ethylene Glycol and Diethylene Glycol
*GB 31604.43-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Migration of Ethylenediamine and Hexamethylene Diamine
*GB 31604.35-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Perfluorooctane Sulfonate (PFOS) and Perfluorooctanoate (PFOA)
*GB 31604.46-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Free Phenols and Determination of Migration
*GB/T 33107-2016 Dimethyl carbonate for industrial use
*GB/T 33014.5-2016 Road vehicles一Component test methods for electrical/electronic disturbances from narrowband radiated electroagnetic energy一Parts:Stripline
*GB/T 33014.2-2016 Road vehicles一Component test methods for electrical/electronic disturbances from narrowband radiated electromagnetic energy一 Part2:Absorbe-lined shielded enclosure
*GB 2099.3-2015 Plugs and socket-outlets for household and similar purposes―Part 2-5:Particular requirements for adaptors
*GB 9685-2016 National Food Safety Standard Standard for Uses of Additives in Food Contact Materials and Their Products
*JB/T 12968-2016 Three-phase induction motor for variable frequency speed adjusting control for shield machine-Specification
GB 31604.27-2016 is referred in:
*GB 31604.19-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Caprolactam and Determination of Migration
*GB 31604.17-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of the Content and Migration of Acrylonitrile
*GB 31604.16-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of Styrene and Ethylbenzene
*GB 31604.14-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Migration of 1-octene and Tetrahydrofuran
*GB 31604.13-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of Migration of 11-aminoundecanoic Acid
*GB 31604.12-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of 1,3-butadiene and Determination of Migration
*GB 31604.11-2016 National Food Safety Standard - Food Contact Materials and Articles - Determination of Migration of 1,3-benzenedimethanamine
*GB 14934-2016 National food safety standard - Disinfection of dinner and drinking set
*GB 31604.49-2016 National Food Safety Standard -Food Contact Materials and Articles – Determination of Arsenic, Cadmium, Chromium and Lead; Migration of Arsenic, Cadmium, Chromium, Nickel, Lead, Antimony and Zinc
*GB/T 33093-2016 Determination of chromium(Ⅵ)content in textiles dyeing and finishing auxiliaries
*GB/T 33084-2016 Heavy alloy structural steel forgings―Technical specification
*GB/T 601-2016 Chemical Reagent - Preparations of Standard Volumetric Solutions
*GB 31604.15-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Migration of 2,4,6-triamino-1,3,5-triazine(melamine)
Code of China
Standard
GB 31604.27-2016  National Food Safety Standard - Food Contact Materials and Articles -Determination of Ethylene Oxide and Propylene Oxide in Plastics (English Version)
Standard No.GB 31604.27-2016
Statusvalid
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)80.0
Implemented on2017-4-19
Deliveryvia email in 1 business day
Detail of GB 31604.27-2016
Standard No.
GB 31604.27-2016
English Name
National Food Safety Standard - Food Contact Materials and Articles -Determination of Ethylene Oxide and Propylene Oxide in Plastics
Chinese Name
食品安全国家标准 食品接触材料及制品 塑料中环氧乙烷和环氧丙烷的测定
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
National Health and Family Planning Commission
Issued on
2016-10-19
Implemented on
2017-4-19
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB/T 23296.11-2009 GB/T 23296.11-2009
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
80.0
Keywords
GB 31604.27-2016, GB/T 31604.27-2016, GBT 31604.27-2016, GB31604.27-2016, GB 31604.27, GB31604.27, GB/T31604.27-2016, GB/T 31604.27, GB/T31604.27, GBT31604.27-2016, GBT 31604.27, GBT31604.27
Introduction of GB 31604.27-2016
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard replaces GB/T 23296.11-2009 Food Contact Materials - Determination of Ethylene Oxide and Propylene Oxide in Plastics - Gas Chromatography. The following main changes have been made with respect to GB/T 23296.11-2009 (the previous edition): ——This standard is renamed as National Food Safety Standard - Food Contact Materials and Articles - Determination of Ethylene Oxide and Propylene Oxide in Plastics; ——"Headspace gas chromatography-mass spectrometry" for determination of ethylene oxide and propylene oxide is added. National Food Safety Standard Food Contact Materials and Articles Determination of Ethylene Oxide and Propylene Oxide in Plastics 1 Scope This standard specifies determination method of ethylene oxide and propylene oxide in food contact materials and articles. This standard is applicable to determination of ethylene oxide and propylene oxide in plastic food contact materials and articles. Method I Headspace Gas chromatography-mass Spectrometry 2 Principle Extract ethylene oxide or propylene oxide in the sample with N, N-dimethyl acetamide (DMAC), conduct headspace sample injection, separate ethylene oxide or propylene oxide and ethyl ether (internal standard) and other components in chromatographic column, examine by mass spectrometry detector and carry out quantative determination by internal standard method. 3 Reagents and Materials Unless otherwise specified, analytically-pure reagents and Class-I water (defined in GB/T 6682) are adopted for the purpose of this method. 3.1 Reagents N,N-dimethyl acetamide (DMAC for short, C4H9NO, CAS No.: 127-19-5): chromatographically pure, peak area of impurity with the same retention time as ethylene oxide or propylene oxide in chromatogram shall not exceed 1%. 3.2 Standard product 3.2.1 Ethylene oxide (C2H4O, CAS No.: 75-21-8): with purity ≥99%, or reference material approved and awarded with reference material certificate by the State. 3.2.2 Propylene oxide(C3H6O, No.: 200-879-2): with purity ≥99%, or reference material approved and awarded with reference material certificate by the State. 3.2.3 Ethyl ether (C4H10O, CAS No.: 60-29-7): with purity≥99.5%, or reference material approved and awarded with reference material certificate by the State. Peak area of impurity with the same retention time as ethylene oxide or propylene oxide shall not exceed 1%. 3.3 Preparation of standard solution 3.3.1 Ethylene oxide standard stock solution Weigh 50 mg (accurate to 0.0001 g) ethylene oxide, dissolve with DMAC, scale the volume to 50mL and prepare into stock solution with concentration of 1 mg/mL. Seal preserve in dark place at 4℃, with the valid period of 2 months. 3.3.2 Propylene oxide standard stock solution Weigh 50 mg (accurate to 0.0001 g) propylene oxide, dissolve with DMAC, scale the volume to 50 mL and prepare into stock solution with concentration of 1 mg/mL. The storage conditions of the solution are as specified in 3.3.1. 3.3.3 Ethylene oxide and propylene oxide mixed standard intermediate solution Measure 5 mL DMAC into 50 mL volumetric flask, respectively pipet 2.0 mL ethylene oxide standard stock solution (3.3.1) and 1.0 mL propylene oxide standard stock solution (3.3.2) into the volumetric flask, scale the volume with DMAC and obtain ethylene oxide and propylene oxide mixed standard intermediate solution. In the solution, concentrations of ethylene oxide and propylene oxide are 40.0 μg/mL and 20.0 μg/mL respectively. The storage conditions of the solution are as specified in 3.3.1. 3.3.4 Ethylene oxide and propylene oxide mixed standard solution Pipet 5.0 mL DMAC into six 10 mL volumetric flasks respectively with graduated pipette, respectively pipet 25 μL, 50 μL, 100 μL, 250 μL, 500 μL and 1,000 μL ethylene oxide and propylene oxide mixed standard intermediate solution (3.3.3) into these six volumetric flasks with microinjector and scale the volume with DMAC. The concentrations of ethylene oxide are 0.1 μg/mL, 0.2 μg/mL, 0.4 μg/mL, 1.0 μg/mL, 2.0 μg/mL and 4.0 μg/mL, and those of propylene oxide are 0.05 μg/mL, 0.1 μg/mL, 0.2 μg/mL, 0.5 μg/mL, 1.0 μg/mL and 2.0 μg/mL. The storage conditions of the solution are as specified in 3.3.1. 3.3.5 Ethyl ether internal standard stock solution Weigh 50 mg (accurate to 0.0001 g) ethyl ether into 50 mL volumetric flask containing 5 mL DMAC, scale the volume with DMAC and prepare into stock solution with concentration of 1 mg/mL. The storage conditions of the solution are as specified in 3.3.1. 3.3.6 Ethyl ether internal standard intermediate solution Measure 5 mL DMAC into 10 mL volumetric flask, pipet 2.5 mL ethyl ether internal standard stock solution (3.3.5) into the volumetric flask with graduated pipette, scale the volume with DMAC and obtain ethyl ether internal standard intermediate solution. The concentration of this solution is 250.0 μg/mL. The storage conditions of the solution are as specified in 3.3.1. 4 Instruments and Apparatus 4.1 Gas chromatography - mass spectrometer: equipped with electron bombardment ion source (EI) and headspace automatic sample injector. 4.2 Microinjector: 10 μL, 100μL and 1,000 μL. 4.3 Headspace bottle: 20mL; equipped with aluminium cap and butyl rubber or silicone resin rubber isolation pad whose side contacting sample shall be coated with polytetrafluoroethylene. 4.4 Analytical balance: with sensibility of 0.0001g . 4.5 Mechanical oscillator. 5 Analysis Steps 5.1 Specimen treatment As for specimens that can be dissolved in DMAC, directly weigh them; as for specimens that are not dissolved in DMAC, weigh them as early as possible after crushing them into fragments with particle size less than 1 mm× 1mm with freezing grinder or scissor or other cutting tools and they cannot be heated or softened during cutting. 5.2 Preparation of specimen solution Weigh 1.0 g±0.1 g specimen (5.1) into headspace bottle, pipet 5.0 mL DMAC into the headspace bottle with graduated pipette, add 10 μL ethyl ether internal standard intermediate solution (3.3.6) with microinjector and seal with cap as early as possible. Oscillate headspace bottle with oscillator at frequency of one time every two seconds till specimen dissolution as for specimen that can be dissolved in DMAC and 4 h for DMAC that is not dissolved in DMAC. If sample concentration exceeds linear range, properly dilute the sample with DMAC before adding internal standard solution to make its concentration within the linear range.
Contents of GB 31604.27-2016
Foreword i 1 Scope 2 Principle 3 Reagents and Materials 4 Instruments and Apparatus 5 Analysis Steps 6 Expression of Analysis Result 7 Accuracy 8 Other 9 Principle 10 Reagents and Materials 11 Instruments and Apparatus 12 Analysis Steps 13 Expression of Analysis Result 14 Accuracy 15 Other Annex A Standard Chromatogram of Ethylene Oxide and Propylene Oxide
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 31604.27-2016, GB/T 31604.27-2016, GBT 31604.27-2016, GB31604.27-2016, GB 31604.27, GB31604.27, GB/T31604.27-2016, GB/T 31604.27, GB/T31604.27, GBT31604.27-2016, GBT 31604.27, GBT31604.27