2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 5135.9-2018
GB 5135.9-2018   Automatic sprinkler system—Part 9:Early suppression fast response (ESFR) sprinklers (English Version)
Standard No.: GB 5135.9-2018 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 24500 words Translation Price(USD):400.0 remind me the price change

Email:

Implemented on:2019-4-1 Delivery: via email in 1 business day

→ → →

,,2019-4-1,D8FEA7C26A214CF61538097737520
Standard No.: GB 5135.9-2018
English Name: Automatic sprinkler system—Part 9:Early suppression fast response (ESFR) sprinklers
Chinese Name: 自动喷水灭火系统 第9部分:早期抑制快速响应(ESFR)喷头
Chinese Classification: C83    Fire extinction technology
Professional Classification: GB    National Standard
ICS Classification: 13.220.10 13.220.10    Fire-fighting 13.220.10
Source Content Issued by: SAMR; SAC
Issued on: 2018-09-17
Implemented on: 2019-4-1
Status: valid
Superseding:GB 5135.9-2006 Automatic sprinkler system - Part9: Early Suppression Fast Response (ESFR) Automatic Sprinklers
Target Language: English
File Format: PDF
Word Count: 24500 words
Translation Price(USD): 400.0
Delivery: via email in 1 business day
Automatic sprinkler system — Part 9: Early suppression fast response (ESFR) sprinklers English GB 5135 Automatic sprinkler system consists or will consist of the following parts under the general title: —Part 1: Sprinklers; ─Part 2: Wet system alarm valves, retard chamber, water motor alarm; —Part 3: Water mist nozzles; —Part 4: Dry pipe valves; —Part 5: Deluge alarm valves; —Part 6: Conventional valves; —Part 7: Water flow indicators; —Part 8: Accelerator; —Part 9: Early suppression fast response (ESFR) sprinklers; —Part 10: Pressure switch; —Part 11: Grooved couplings and fittings; —Part 13: Performance requirements and test methods of drencher nozzle —Part 14: Preaction devices; —Part 15: Domestic sprinklers; —Part 16: Flexible sprinkler hose with fittings; —Part 17: Pressure reducing valves; —Part 18: Pipe hangers; —Part 19: Plastic pipe and fittings; —Part 20: Coating steel pipe; —Part 21: Inspector's test connection; —Part 22: Specific application sprinklers; ... This is Part 9 of GB 5135. 1 Scope This standard specifies the classification of ESFR sprinklers, nominal operating temperature, color identification, model specification, requirements, test methods, inspection rules, packaging, transportation and storage, etc. This standard is applicable to K202 (pendent and uprights), K242 (pendent and and upright), K323 (pendent), and K363 (pendent) ESFR sprinklers. For other types of ESFR sprinklers, refer to this part. This part is not applicable to the specific application sprinklers. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 5135.1 Automatic sprinkler system -- Part 1: Sprinklers GB/T 7306.2 Pipe threads with 55 degree thread angle where pressure-tight joints are made on the threads -- Part 2: Taper internal and external threads GB/T 9969.1 General principles for preparation of instructions for use of industrial products GB/T 31431-2015 Standard burning items for class A fire test of extinguishing system 3 Terms and definitions For the purpose of this document, the terms and definitions given in GB 5135.1 and the following apply. 3.1 conductivity factor C a measure of the heat conductance between the sprinkler's heat responsive element and the other components of the sprinkler, expressed in unit of (m/s)1/2 3.2 actual delivered density ADD density of water discharge penetrating the fire plume and reaching the surface of the comburent 3.3 early suppression a characteristic of sprinkler performance whereby the first few operating sprinklers are able to deliver sufficient water to the fire to promptly reduce the fire growth and ultimately suppress the fire to an acceptable level 3.4 early suppression fast response (ESFR) automatic sprinklers sprinklers that discharge water over a designed protection area in certain shape and density to provide early suppression against fire after the heat-sensitive elements are automatically started with prescribed temperature range under thermal action 4 Classification 4.1 Classification according to heat-sensitive elements 4.1.1 Fusible element ESFR sprinkler ESFR sprinkler that opens by the melting of the heated alloy of a fusible element 4.1.2 Glass bulb ESFR sprinkler ESFR sprinkler that is opened by the bursting of the glass bulb resulting from thermal expansion of the fluid filled in the glass bulb 4.2 Classification according to installation positions 4.2.1 Pendent ESFR sprinkler ESFR sprinkler arranged by pendent installation such that the water flow is directed downwards against the deflector 4.2.2 Upright ESFR sprinkler ESFR sprinkler arranged by upright installation such that the water flow is directed upwards against the deflector 5 Nominal operating temperature, color identification and model specification 5.1 Nominal operating temperature and color coding See Table 1 for the nominal operating temperature and color identification of ESFR sprinkler. Table 1 Nominal operating temperature and color identification
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Classification 5 Nominal operating temperature, color identification and model specification 6 Requirements 7 Test methods 8 Inspection rules 9 Packaging, transportation and storage Annex A (Informative) Calculation method of error limit Annex C (Informative) Analysis of the strength test for fusible elements Annex D (Normative) Routine inspection
Referred in GB 5135.9-2018:
*GB 5135.1-2019 Automatic sprinkler system—Part 1:Sprinkler
*GB/T 7306.2-2000 Pipe threads with 55 degree thread angle where pressure-tight joints are made on the threads--Part 2:Taper internal and external threads
*GB/T 9969.1-1988 General principles for preparation of instructions for use of industrial products
*GB/T 31431-2015 Standard burning items for class A fire test of extinguishing system
*GB 2762-2022 National Food Safety Standard - Maximum Levels of Contaminants in Foods
*GB/T 8897.2-2021 Primary batteries—Part 2: Physical and electrical specifications
*FZ/T 81007-2003 Casual wear
*GB 8898-2011 Audio,video and similar electronic apparatus—Safety requirements
*GB/T 22849-2014 Knitted T-shirt
*FZ/T 81007-2012 Casual wear
*GB/T 8163-2018 Seamless steel pipes for liquid service
*GA 374-2019 Burglary-resistant electronic locks
*GB 50009-2012 Load Code for the Design of Building Structures
*GB/T 26572-2011 Requirements of concentration limits for certain restricted substances in electrical and electronic products
*GB 4806.7-2016 National Food Safety Standard - Food Contact Plastic Materials and Articles
*GB/T 1591-2018 High strength low alloy structural steels
*FZ/T 81006-2017 Jeanswear
*GB 2763-2021 National Food Safety Standard-Maximum Residue Limits for Pesticides in Food
*GB 9706.1-2020 Medical electrical equipment—Part 1: General requirements for basic safety and essential performance
*SJ/T 11364-2014/XG1-2017 Marking for the restriction of the use of hazardous substances in electrical and electronic product,including Amendment 1
*GBT32960-
*GB/T 22849-2014 Knitted T-shirt
Code of China
Standard
GB 5135.9-2018  Automatic sprinkler system—Part 9:Early suppression fast response (ESFR) sprinklers (English Version)
Standard No.GB 5135.9-2018
Statusvalid
LanguageEnglish
File FormatPDF
Word Count24500 words
Price(USD)400.0
Implemented on2019-4-1
Deliveryvia email in 1 business day
Detail of GB 5135.9-2018
Standard No.
GB 5135.9-2018
English Name
Automatic sprinkler system—Part 9:Early suppression fast response (ESFR) sprinklers
Chinese Name
自动喷水灭火系统 第9部分:早期抑制快速响应(ESFR)喷头
Chinese Classification
C83
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2018-09-17
Implemented on
2019-4-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 5135.9-2006 Automatic sprinkler system - Part9: Early Suppression Fast Response (ESFR) Automatic Sprinklers
Language
English
File Format
PDF
Word Count
24500 words
Price(USD)
400.0
Keywords
GB 5135.9-2018, GB/T 5135.9-2018, GBT 5135.9-2018, GB5135.9-2018, GB 5135.9, GB5135.9, GB/T5135.9-2018, GB/T 5135.9, GB/T5135.9, GBT5135.9-2018, GBT 5135.9, GBT5135.9
Introduction of GB 5135.9-2018
Automatic sprinkler system — Part 9: Early suppression fast response (ESFR) sprinklers English GB 5135 Automatic sprinkler system consists or will consist of the following parts under the general title: —Part 1: Sprinklers; ─Part 2: Wet system alarm valves, retard chamber, water motor alarm; —Part 3: Water mist nozzles; —Part 4: Dry pipe valves; —Part 5: Deluge alarm valves; —Part 6: Conventional valves; —Part 7: Water flow indicators; —Part 8: Accelerator; —Part 9: Early suppression fast response (ESFR) sprinklers; —Part 10: Pressure switch; —Part 11: Grooved couplings and fittings; —Part 13: Performance requirements and test methods of drencher nozzle —Part 14: Preaction devices; —Part 15: Domestic sprinklers; —Part 16: Flexible sprinkler hose with fittings; —Part 17: Pressure reducing valves; —Part 18: Pipe hangers; —Part 19: Plastic pipe and fittings; —Part 20: Coating steel pipe; —Part 21: Inspector's test connection; —Part 22: Specific application sprinklers; ... This is Part 9 of GB 5135. 1 Scope This standard specifies the classification of ESFR sprinklers, nominal operating temperature, color identification, model specification, requirements, test methods, inspection rules, packaging, transportation and storage, etc. This standard is applicable to K202 (pendent and uprights), K242 (pendent and and upright), K323 (pendent), and K363 (pendent) ESFR sprinklers. For other types of ESFR sprinklers, refer to this part. This part is not applicable to the specific application sprinklers. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB 5135.1 Automatic sprinkler system -- Part 1: Sprinklers GB/T 7306.2 Pipe threads with 55 degree thread angle where pressure-tight joints are made on the threads -- Part 2: Taper internal and external threads GB/T 9969.1 General principles for preparation of instructions for use of industrial products GB/T 31431-2015 Standard burning items for class A fire test of extinguishing system 3 Terms and definitions For the purpose of this document, the terms and definitions given in GB 5135.1 and the following apply. 3.1 conductivity factor C a measure of the heat conductance between the sprinkler's heat responsive element and the other components of the sprinkler, expressed in unit of (m/s)1/2 3.2 actual delivered density ADD density of water discharge penetrating the fire plume and reaching the surface of the comburent 3.3 early suppression a characteristic of sprinkler performance whereby the first few operating sprinklers are able to deliver sufficient water to the fire to promptly reduce the fire growth and ultimately suppress the fire to an acceptable level 3.4 early suppression fast response (ESFR) automatic sprinklers sprinklers that discharge water over a designed protection area in certain shape and density to provide early suppression against fire after the heat-sensitive elements are automatically started with prescribed temperature range under thermal action 4 Classification 4.1 Classification according to heat-sensitive elements 4.1.1 Fusible element ESFR sprinkler ESFR sprinkler that opens by the melting of the heated alloy of a fusible element 4.1.2 Glass bulb ESFR sprinkler ESFR sprinkler that is opened by the bursting of the glass bulb resulting from thermal expansion of the fluid filled in the glass bulb 4.2 Classification according to installation positions 4.2.1 Pendent ESFR sprinkler ESFR sprinkler arranged by pendent installation such that the water flow is directed downwards against the deflector 4.2.2 Upright ESFR sprinkler ESFR sprinkler arranged by upright installation such that the water flow is directed upwards against the deflector 5 Nominal operating temperature, color identification and model specification 5.1 Nominal operating temperature and color coding See Table 1 for the nominal operating temperature and color identification of ESFR sprinkler. Table 1 Nominal operating temperature and color identification
Contents of GB 5135.9-2018
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Classification 5 Nominal operating temperature, color identification and model specification 6 Requirements 7 Test methods 8 Inspection rules 9 Packaging, transportation and storage Annex A (Informative) Calculation method of error limit Annex C (Informative) Analysis of the strength test for fusible elements Annex D (Normative) Routine inspection
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 5135.9-2018, GB/T 5135.9-2018, GBT 5135.9-2018, GB5135.9-2018, GB 5135.9, GB5135.9, GB/T5135.9-2018, GB/T 5135.9, GB/T5135.9, GBT5135.9-2018, GBT 5135.9, GBT5135.9