2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 17650.2-1998
GB/T 17650.2-1998   Test on gases evolved during combustion of materials from cables - Part 2: Determination of degree of acidity of gases by measuring pH and conductivity (English Version)
Standard No.: GB/T 17650.2-1998 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3000 words Translation Price(USD):90.0 remind me the price change

Email:

Implemented on:1999-10-1 Delivery: via email in 1 business day

→ → →

,2021-11-1,1999-10-1,141138180701119B3577B84A4FD0E
Standard No.: GB/T 17650.2-1998
English Name: Test on gases evolved during combustion of materials from cables - Part 2: Determination of degree of acidity of gases by measuring pH and conductivity
Chinese Name: 取自电缆或光缆的材料燃烧时释出气体的试验方法 第2部分:用测量pH值和电导率来测定气体的酸度
Chinese Classification: K13    Cable and its accessory
Professional Classification: GB    National Standard
ICS Classification: 29.060.01 29.060.01    Electrical wires and cables in general 29.060.01
Source Content Issued by: AQSIQ
Issued on: 1998-1-2
Implemented on: 1999-10-1
Status: superseded
Superseded by:GB/T 17650.2-2021 Test on gases evolved during combustion of materials from cables or optical fiber cables - Part 2: Determination of acidity (by pH measurement) and conductivity
Superseded on:2021-11-1
Target Language: English
File Format: PDF
Word Count: 3000 words
Translation Price(USD): 90.0
Delivery: via email in 1 business day
1 Scope Part 2 of this standard specifies a method for the determination of the degree of acidity of gases evolved during the combustion of compounds taken from the components of electric or optical cables. Note 1: The relevant cable standard should indicate which components of the cable should be tested, and which method of calculation (see clause 8) should be used in the case of dispute. Note 2: For the purposes of this standard the term “electric cable” covers all insulated metallic conductor cables used for the conveyance of energy or signals. 2 Principle of the Method A pre-determined quantity of the test material is burned in a tube furnace. The evolved gases are trapped by bubbling through bottles filled with distilled or demineralized water. The acidity is measured by determination of pH value. The conductivity of the solution is also measured. 3 Test Apparatus The principle diagram of the apparatus is shown in Figures 1 to 5. The assembly of the components which constitute the test apparatus shall be leak-tight. The connections between the tube and the first wash bottle and between the first and the second wash bottle shall be as short as possible. 3.1 Tube furnace The effective length of the heating zone of the furnace shall be 500 mm to 600 mm and its inside diameter 40 mm to 60 mm. It shall be equipped with an adjusted electric heating system.   3.2 Tube The furnace contains a fireproof tube made of silica resistant to the action of corrosive gases. The tube shall be approximately concentric to the tube furnace. The inside diameter of the silica tube shall be within the limits of 32 mm to 45 mm. The initial clearance shall only allow for thermal expansion. The tube protrudes on each side by a length L of: — on the entrance side: 60 mm ≤ L ≤ 200 mm; — on the exit side: 60 mm ≤ L ≤ 100 mm. 3.3 Combustion boats
1 Scope 2 Principle of the Method 3 Test Apparatus 4 Conditioning of the Samples 5 Test Pieces 6 Test Procedure 7 Determination of the pH Value and Conductivity 8 Expression of the Results 9 Recommended Values
GB/T 17650.2-1998 is referred in:
*CQC 1104-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems Part 2: Cables for AC Charging Systems
*CQC 1103-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems Part 1: General Requiremen
*TB/T 1484.2-2010 Specification for cables on board rolling stock - Part 2: Thin wall insulation cables
*TB/T 1484.1-2010 Specification for cables on board rolling stock - Part 1: Standard wall insulation cables up to AC 3 kV
*GB/T 12528-2008 Rail vehicle cables with rated voltages up to and including 3kV
*TB/T 1484.2-2017 Specification for cables on board rolling stock-Part 2:30kVsingle phase power cables
*GB/T 12706.1-2008 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 1: Cables for rated voltage of 1kV (Um=1.2kV) and 3kV (Um=3.6kV)
*JB/T 10491.1-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V Part1: General requirements
*JB/T 10491.2-2004 Cross-linked polyolefin insulated wires and cables with rated voltages up to and including 450/750V Part2:
*GB/T 12706.1-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 1: Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
*GB/T 12706.2-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 2: Cables for rated voltages from 6 kV(Um=7.2 kV) up to 30 kV(Um=36 kV)
*GB/T 12706.3-2020 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV)—Part 3: Cables for rated voltages of 35kV(Um=40.5kV)
*GB/T 17650.1-1998 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas
*YD/T 1155-2001 Figure 8 Self - support Optical Fiber Cables for Outdoor Telecommunication
*YD/T 3350.1-2018 Gel-free optical fiber cables for outdoor application for telecommunication Part 1:Stranded loose tube cables
*GB/T 28427-2012 27.5 kV single-phase AC XLPE insulation cable and accessories for electrification railway
*YD/T 769-2018 Central gel-filled loose tube optical fibre cables for outdoor application for telecommunication
*GB/T 32129-2015 Halogen free low smoke and flame-retardant compounds for wires and cables
*GB/T 19666-2005 Flame retardant and fire resistant wires and cables
*GB/T 33594-2017 Charging cables for electric vehicles
*CQC 1105-2015 Technical Specification for Cables of Electric Vehicles Conductive Charging Systems Part 3: Cables for DC Charging Systems
Code of China
Standard
GB/T 17650.2-1998  Test on gases evolved during combustion of materials from cables - Part 2: Determination of degree of acidity of gases by measuring pH and conductivity (English Version)
Standard No.GB/T 17650.2-1998
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count3000 words
Price(USD)90.0
Implemented on1999-10-1
Deliveryvia email in 1 business day
Detail of GB/T 17650.2-1998
Standard No.
GB/T 17650.2-1998
English Name
Test on gases evolved during combustion of materials from cables - Part 2: Determination of degree of acidity of gases by measuring pH and conductivity
Chinese Name
取自电缆或光缆的材料燃烧时释出气体的试验方法 第2部分:用测量pH值和电导率来测定气体的酸度
Chinese Classification
K13
Professional Classification
GB
ICS Classification
Issued by
AQSIQ
Issued on
1998-1-2
Implemented on
1999-10-1
Status
superseded
Superseded by
GB/T 17650.2-2021 Test on gases evolved during combustion of materials from cables or optical fiber cables - Part 2: Determination of acidity (by pH measurement) and conductivity
Superseded on
2021-11-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
3000 words
Price(USD)
90.0
Keywords
GB/T 17650.2-1998, GB 17650.2-1998, GBT 17650.2-1998, GB/T17650.2-1998, GB/T 17650.2, GB/T17650.2, GB17650.2-1998, GB 17650.2, GB17650.2, GBT17650.2-1998, GBT 17650.2, GBT17650.2
Introduction of GB/T 17650.2-1998
1 Scope Part 2 of this standard specifies a method for the determination of the degree of acidity of gases evolved during the combustion of compounds taken from the components of electric or optical cables. Note 1: The relevant cable standard should indicate which components of the cable should be tested, and which method of calculation (see clause 8) should be used in the case of dispute. Note 2: For the purposes of this standard the term “electric cable” covers all insulated metallic conductor cables used for the conveyance of energy or signals. 2 Principle of the Method A pre-determined quantity of the test material is burned in a tube furnace. The evolved gases are trapped by bubbling through bottles filled with distilled or demineralized water. The acidity is measured by determination of pH value. The conductivity of the solution is also measured. 3 Test Apparatus The principle diagram of the apparatus is shown in Figures 1 to 5. The assembly of the components which constitute the test apparatus shall be leak-tight. The connections between the tube and the first wash bottle and between the first and the second wash bottle shall be as short as possible. 3.1 Tube furnace The effective length of the heating zone of the furnace shall be 500 mm to 600 mm and its inside diameter 40 mm to 60 mm. It shall be equipped with an adjusted electric heating system.   3.2 Tube The furnace contains a fireproof tube made of silica resistant to the action of corrosive gases. The tube shall be approximately concentric to the tube furnace. The inside diameter of the silica tube shall be within the limits of 32 mm to 45 mm. The initial clearance shall only allow for thermal expansion. The tube protrudes on each side by a length L of: — on the entrance side: 60 mm ≤ L ≤ 200 mm; — on the exit side: 60 mm ≤ L ≤ 100 mm. 3.3 Combustion boats
Contents of GB/T 17650.2-1998
1 Scope 2 Principle of the Method 3 Test Apparatus 4 Conditioning of the Samples 5 Test Pieces 6 Test Procedure 7 Determination of the pH Value and Conductivity 8 Expression of the Results 9 Recommended Values
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 17650.2-1998, GB 17650.2-1998, GBT 17650.2-1998, GB/T17650.2-1998, GB/T 17650.2, GB/T17650.2, GB17650.2-1998, GB 17650.2, GB17650.2, GBT17650.2-1998, GBT 17650.2, GBT17650.2