2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 19666-2005
GB/T 19666-2005   Flame retardant and fire resistant wires and cables (English Version)
Standard No.: GB/T 19666-2005 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 3500 words Translation Price(USD):70.0 remind me the price change

Email:

Implemented on:2005-8-1 Delivery: via email in 1 business day

→ → →

2020-07-01 ,2020-7-1,2005-8-1,14113818180967A1FB5DA7AF165DB
Standard No.: GB/T 19666-2005
English Name: Flame retardant and fire resistant wires and cables
Chinese Name: 阻燃和耐火电线电缆通则
Chinese Classification: K13    Cable and its accessory
Professional Classification: GB    National Standard
ICS Classification: 29.060.20 29.060.20    Cables 29.060.20
Source Content Issued by: AQSIQ; SAC
Issued on: 2005-4-4
Implemented on: 2005-8-1
Status: superseded
Superseded by:GB/T 19666-2019 General rules for flame retardant and fire resistant electric wires and cables or optical fiber cables
Superseded on:2020-7-1
Abolished on:2020-07-01
Target Language: English
File Format: PDF
Word Count: 3500 words
Translation Price(USD): 70.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. Flame-retardant and fire-resistant wires and cables, including halogen-containing, halogen-free, low-smoke ones, have been produced and used for more than ten years in China and are of far reaching importance to fire safety. However, on account of lack of international standards and national standards, the products are in chaos in terms of name, model, technical requirements, test methods etc., some of which are also inconsistent with international requirements. This standard is formulated to unify domestic manufacturing and application and meets the requirements of international trade and economic & technical interchange. Provided that almost all electrical wires and cables are required to be flame-retardant and fire-resistant, in general, the materials adopted need to be changed instead of the structure of wires and cables to achieve this goal. Therefore, this standard is formulated instead of formulation of product standards one by one, in which combustion characteristics requirements (flame retardance and fire resistance etc.) different from current common product standards are specified, available flame-retardant or fire-resistant materials are recommended, and corresponding marks are added before common product models to make distinction from common products. In this standard, test methods and performance requirements for relevant halogen free, low smoke, flame retardance and fire resistance characteristics are all in accordance with latest editions of the following international standards: IEC 60331: 1999 Tests for Electric Cables under Fire Conditions - Circuit Integrity IEC 60332: 2000 Tests on Electric and Optical Fibre Cables under Fire Conditions IEC 60754: 1997 Tests on Gases Evolved during Combustion of Electrical Cables IEC 61034: 1997 Determination of Smoke Density for Combustion of Electrical Cables under Specified Conditions This standard may be used as product standard directly. In case the standards for single-series products are required to be prepared, relevant contents must be in accordance with those specified in this standard. Appendixes A, B and C of this standard are informative. This standard is a national standard formulated for the first time. This standard is proposed by China Electrical Equipment Industrial Association. This standard is under the jurisdiction of National Technical Committee on Wire and Cables of Standardization Administration of China. Drafting organization of this standard: Shanghai Electric Cable Research Institute. Participating drafting organizations of this standard: Tianjin Fire Research Institute of Ministry of Public Security, East China Architectural Design & Research Institute Co., Ltd., Yangzhou Shuguang Cable Factory, Shanghai Maqiao Cable Factory, Baosheng Science and Technology Innovation Co., Ltd., Jiangsu Shangshang Cable Group Co., Ltd., Hengtong Group Co., Ltd., Far East Cable Factory, Jiangsu Samson Cable Co., Ltd., Foshan Zhongbao Cable Factory, Shanghai Cable Works Shifen Factory, Huaian Bafang Cable Factory, Wuxi El Pont Polymer Co.,Ltd. Drafting staff of this standard: Xu Yinglin, Dai Dianfeng, Shen Yuxiang, Gu Liyun, Zhou Yan, Tang Chongjian, Wang Songming, Liu Genrong, Wang Chuanbin, Sun Ping, Luo Pinguang, Zhang Zhiqing, Sun Yueming, You Yong. NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA 中华人民共和国国家标准 GB/T 19666-2005 Flame Retardant and Fire Resistant Wires and Cables 阻燃和耐火电线电缆通则 1 Scope This standard specifies the models, technical requirements, test methods and acceptance rules regarding flame retardant and fire resistant wires and cables which are halogen-containing, halogen-free and low-smoke. This standard is applicable to halogen-containing, halogen-free and low-smoke flame retardant and fire resistant wires and cables. 2 Normative References The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding corrigendum), or revisions of, any of these publications do not apply. However, all parties coming to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards. For undated references, the latest edition of the normative document referred to applies. GB/T 17650.2-1998 Test on Gases Evolved during Combustion of Materials from Cables - Part 2: Determination of Degree of Acidity of Gases by Measuring pH and Conductivity (idt IEC 60754-2: 1991) GB/T 17651.2-1998 Measurement of Smoke Density of Cables Burning under Defined Conditions - Part 2: Test Procedure and Requirements (idt IEC 61034-2: 1997) GB/T 18380.1-2001 Tests on Electric Cables under Fire Conditions - Part 1: Test on a Single Vertical Insulated Wire or Cable (idt IEC 60332-1: 1993) GB/T 18380.2-2001 Tests on Electric Cables under Fire Conditions - Part 2: Test on a Single Small Vertical Insulated Copper Wire or Cable (idt IEC 60332-2: 1989) GB/T 18380.3-2001 Tests on Electric Cables under Fire Conditions - Part 3: Test on Bunched Wire or Cable (idt IEC 60332-3: 1992) GB/T 19216.21-2003 Tests for Electric Cables under Fire Conditions - Circuit Integrity - Part 21: Procedures and Requirements - Cable of Rated Voltage up to and Including 0.6/1.0kV (idt IEC 60331-21: 1999) GB/T 19216.23-2003 Tests for Electric Cables under Fire Conditions - Circuit Integrity - Procedures and Requirements - Electric Data Cables (idt IEC 60331-23: 1999) IEC 60332-3-25: 2000 Tests on Electric and Optical Fiber Cables under Fire Conditions - Part 25: Test for Flame Spread of Bunched Wires or Cables - Category D 3 Terms and Definitions 3.1 Flame retardance The characteristic that flame spreads on the sample within limited scope and extinguishes by itself in case the sample is burned under specified test condition and the fire source is removed, i.e. the capacity to retard occurrence or spreading of the flame. 3.2 Fire resistance The capacity to keep continuous operation under specified state in case of being burned under specified fire source and time, i.e. the capacity to maintain integrity of the line. 3.3 Halogen free Free from halogen, relatively low corrosivity of combustion products. 3.4 Low smoke Less smoke dust generated in case of being burned, namely relatively high light transmittance (visibility). 4 Models 4.1 Composition of model The models of flame retardant and fire resistant wires and cables are composed of two parts: codes for combustion characteristics of products and models of relevant wires and cables, see Figure 1. Figure 1 Composition of Models of Flame Retardant and Fire Resistant Wires and Cables 4.2 Codes and sequential arrangement of combustion characteristics 4.2.1 See Table 1 for codes of combustion characteristics. Table 1 Codes of Combustion Characteristics Code Designation Za ZA ZB ZC ZDb Omitted W D U N NJ NS Flame retardance Category A flame retardance Category B flame retardance Category C flame retardance Category D flame retardance Halogen containing Halogen free Low smoke Low toxicity Fire resistance Fire resistance + impact Fire resistance + water jet a Z represents single flame retardance, only used for products with halogen free base materials. For those with halogen containing base materials, Z is omitted. b ZD represents Category D bunched flame retardance, is applicable to the relatively thin products with the outside diameter ≤ 12mm. 4.2.2 See Table 2 for the current codes for combustion characteristics of products. Where various combustion characteristics are required, their codes are arranged in the sequence of halogen free (halogen containing is omitted), low smoke, low toxicity, flame retardance or fire resistance. Table 2 Current Codes for Combustion Characteristics of Products Series designation Code Designation Flame retardance series Halogen containing ZA ZB ZC ZD Category A flame retardance Category B flame retardance Category C flame retardance Category D flame retardance Halogen free, low smoke WDZ WDZA WDZB WDZC WDZD Halogen free, low smoke, flame retardance Category A halogen free, low smoke, flame retardance Category B halogen free, low smoke, flame retardance Category C halogen free, low smoke, flame retardance Category D halogen free, low smoke, flame retardance Fire resistance series Halogen containing N ZAN ZBN ZCN ZDN Fire resistance Category A flame retardance, fire resistance Category B flame retardance, fire resistance Category C flame retardance, fire resistance Category D flame retardance, fire resistance Halogen free, low smoke WDZN WDZAN WDZBN WDZCN WDZDN Halogen free, low smoke, flame retardance, fire resistance Category A halogen free, low smoke, flame retardance and fire resistance Category B halogen free, low smoke, flame retardance and fire resistance Category C halogen free, low smoke, flame retardance and fire resistance Category D halogen free, low smoke, flame retardance and fire resistance Note: Other codes are under consideration. 4.3 Models of wires and cables Models of wires and cables are generally composed of series codes, material codes as well as operating characteristics and structure characteristics. Models of relevant wires and cables are directly adopted in this standard. However, meaning of the following codes is expanded as follows: Y——Polyethylene or polyolefin insulation or sheath; YJ——Cross-linked polyethylene or cross-linked polyolefin insulation or sheath; 3——Polyethylene or polyolefin outer sheath; 4——Cross-linked polyethylene or elastomer outer sheath; 6——Nonmagnetic metal tape armour; 7——Nonmagnetic metal wire armour. 4.4 Expression method of products The products are expressed with "model, specification and serial number of this standard / relevant product standards". See Appendix A for relevant product standards. Example 1: Category A flame-retardant power cable with polyvinyl chloride insulation and polyvinyl chloride sheath is expressed as: ZA-VV Specification (omitted) GB/T 19666-2005/GB/T 12706.1-2002 Example 2: Category B flame-retardant power cable with cross-linked polyethylene insulation and polyvinyl chloride sheath is expressed as: ZB-YJV Specification (omitted) GB/T 19666-2005/GB/T 12706.1-2002 Example 3: Category C flame-retardant and fire-resistant power cable with cross-linked polyethylene insulation and polyvinyl chloride sheath is expressed as: ZCN-YJV Specification (omitted) GB/T 19666-2005/GB/T 12706.1-2002 Example 4: halogen-free, low-smoke and Category B flame-retardant power cable with cross-linked polyethylene insulation and polyolefin sheath is expressed as: WDZB-YJY Specification (omitted) GB/T 19666-2005/GB/T 12706.1-2002 Example 5: Category D flame retardant wires with polyvinyl chloride insulation for fixed wiring is expressed as: ZD-BV Specification (omitted) GB/T 19666-2005/GB 5023.3-1997 Example 6: Category C flame-retardant cable with polyvinyl chloride insulation and light polyvinyl chloride sheath is expressed as: ZC-BVV Specification (omitted) GB/T 19666-2005/GB 5023.4-1997 Example 7: Category A flame-retardant control cable with polyvinyl chloride insulation and steel tape armoring polyvinyl chloride sheath is expressed as: ZA-KVV22 Specification (omitted) GB/T 19666-2005/GB 9330-1988 Example 8: halogen-free, low-smoke and Category B flame-retardant local communication cable with polyolefin insulation, filled moisture-proof layer polyolefin sheath and single-layer vertically wrapped and rolled steel tape armoring polyolefin coat is expressed as: WDZB-HYAT53 Specification (omitted) GB/T 19666-2005/GB/T 13849.2-1993
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Models 5 Combustion Characteristics Requirements 6 Technical Requirements 7 Acceptance Rules Appendix A (Informative) Examples of Relevant Standards for Wires and Cables Appendix B (Informative) Technical Performance of Halogen-free Low-smoke Flame Retardant Insulation and Sheath Appendix C (Informative) Technical Performance of Fire Resistant Mica Tape for Wires and Cables
Referred in GB/T 19666-2005:
*GB/T 17650.2-1998 Test on gases evolved during combustion of materials from cables - Part 2: Determination of degree of acidity of gases by measuring pH and conductivity
*GB/T 17651.2-1998 Measurement of smoke density of cables burning under defined conditions - Part 2 : Test procedure and requirements
*GB/T 18380.1-2001 Tests on electric cables under fire conditions-Part 1:Test on a single vertical insulated wire or cable
*GB/T 18380.2-2001 Tests on electric cables under fire conditions-Part 2:Test on a single small vertical insulated copper wire or cable
*GB/T 18380.3-2001 Tests on electric cables under fire conditions-Part 3:Tests on bunched wires or cables
*GB/T 19216.21-2003 Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cable of rated voltage up to and including 0.6/1.0 kV
*GB/T 19216.23-2003 Tests for electric cables under fire conditions - Circuit integrity - Part 23: Procedures and requirements - Electric data cables
GB/T 19666-2005 is referred in:
* GB/T 9330.1-2008 Plastic Insulated Control Cables - Part 1: General Requirements
* GB/T 9330.2-2008 Plastic Insulated Control Cables - Part 2: Polyvinyl Chloride Insulated and Sheathed Control Cables
* GB 13954-2009 Warning lamps for police cars,fire engines,ambulan
* GB/T 9330.3-2008 Plastic insulated control cables - Part 3: Cross-linked polyethylene insulated control cables
* GB 13954-2009 Warning Lamps for Police Cars, Fire Engines, Ambulances and Engineering Rescue Vehicles
* GB/T 9330.3-2008 Plastic insulated control cables - Part 3: Cross-linked polyethylene insulated control cables
* GB/T 9330.3-2008 Plastic insulated control cables - Part 3: Cross-linked polyethylene insulated control cables
* GB/T 9330.1-2008 Plastic Insulated Control Cables - Part 1: General Requirements
* GB/T 9330.2-2008 Plastic Insulated Control Cables - Part 2: Polyvinyl Chloride Insulated and Sheathed Control Cables
* CJ/T 416-2012 Fire Protection Requirements for Urban Rail Transit Vehicles
*GB/T 12528-2008 Rail vehicle cables with rated voltages up to and including 3kV
*GB/T 12706.1-2008 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 1: Cables for rated voltage of 1kV (Um=1.2kV) and 3kV (Um=3.6kV)
*QC/T 1023-2015 General Requirement of Traction Battery System for Electric Vehicles
*GB/T 12706.1-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 1: Cables for rated voltage of 1 kV(Um=1.2 kV)and 3 kV(Um=3.6 kV)
*GB/T 12706.2-2020 Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV)—Part 2: Cables for rated voltages from 6 kV(Um=7.2 kV) up to 30 kV(Um=36 kV)
*GB/T 12706.3-2020 Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV)—Part 3: Cables for rated voltages of 35kV(Um=40.5kV)
Code of China
Standard
GB/T 19666-2005  Flame retardant and fire resistant wires and cables (English Version)
Standard No.GB/T 19666-2005
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count3500 words
Price(USD)70.0
Implemented on2005-8-1
Deliveryvia email in 1 business day
Detail of GB/T 19666-2005
Standard No.
GB/T 19666-2005
English Name
Flame retardant and fire resistant wires and cables
Chinese Name
阻燃和耐火电线电缆通则
Chinese Classification
K13
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2005-4-4
Implemented on
2005-8-1
Status
superseded
Superseded by
GB/T 19666-2019 General rules for flame retardant and fire resistant electric wires and cables or optical fiber cables
Superseded on
2020-7-1
Abolished on
2020-07-01
Superseding
Language
English
File Format
PDF
Word Count
3500 words
Price(USD)
70.0
Keywords
GB/T 19666-2005, GB 19666-2005, GBT 19666-2005, GB/T19666-2005, GB/T 19666, GB/T19666, GB19666-2005, GB 19666, GB19666, GBT19666-2005, GBT 19666, GBT19666
Introduction of GB/T 19666-2005
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. Flame-retardant and fire-resistant wires and cables, including halogen-containing, halogen-free, low-smoke ones, have been produced and used for more than ten years in China and are of far reaching importance to fire safety. However, on account of lack of international standards and national standards, the products are in chaos in terms of name, model, technical requirements, test methods etc., some of which are also inconsistent with international requirements. This standard is formulated to unify domestic manufacturing and application and meets the requirements of international trade and economic & technical interchange. Provided that almost all electrical wires and cables are required to be flame-retardant and fire-resistant, in general, the materials adopted need to be changed instead of the structure of wires and cables to achieve this goal. Therefore, this standard is formulated instead of formulation of product standards one by one, in which combustion characteristics requirements (flame retardance and fire resistance etc.) different from current common product standards are specified, available flame-retardant or fire-resistant materials are recommended, and corresponding marks are added before common product models to make distinction from common products. In this standard, test methods and performance requirements for relevant halogen free, low smoke, flame retardance and fire resistance characteristics are all in accordance with latest editions of the following international standards: IEC 60331: 1999 Tests for Electric Cables under Fire Conditions - Circuit Integrity IEC 60332: 2000 Tests on Electric and Optical Fibre Cables under Fire Conditions IEC 60754: 1997 Tests on Gases Evolved during Combustion of Electrical Cables IEC 61034: 1997 Determination of Smoke Density for Combustion of Electrical Cables under Specified Conditions This standard may be used as product standard directly. In case the standards for single-series products are required to be prepared, relevant contents must be in accordance with those specified in this standard. Appendixes A, B and C of this standard are informative. This standard is a national standard formulated for the first time. This standard is proposed by China Electrical Equipment Industrial Association. This standard is under the jurisdiction of National Technical Committee on Wire and Cables of Standardization Administration of China. Drafting organization of this standard: Shanghai Electric Cable Research Institute. Participating drafting organizations of this standard: Tianjin Fire Research Institute of Ministry of Public Security, East China Architectural Design & Research Institute Co., Ltd., Yangzhou Shuguang Cable Factory, Shanghai Maqiao Cable Factory, Baosheng Science and Technology Innovation Co., Ltd., Jiangsu Shangshang Cable Group Co., Ltd., Hengtong Group Co., Ltd., Far East Cable Factory, Jiangsu Samson Cable Co., Ltd., Foshan Zhongbao Cable Factory, Shanghai Cable Works Shifen Factory, Huaian Bafang Cable Factory, Wuxi El Pont Polymer Co.,Ltd. Drafting staff of this standard: Xu Yinglin, Dai Dianfeng, Shen Yuxiang, Gu Liyun, Zhou Yan, Tang Chongjian, Wang Songming, Liu Genrong, Wang Chuanbin, Sun Ping, Luo Pinguang, Zhang Zhiqing, Sun Yueming, You Yong. NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA 中华人民共和国国家标准 GB/T 19666-2005 Flame Retardant and Fire Resistant Wires and Cables 阻燃和耐火电线电缆通则 1 Scope This standard specifies the models, technical requirements, test methods and acceptance rules regarding flame retardant and fire resistant wires and cables which are halogen-containing, halogen-free and low-smoke. This standard is applicable to halogen-containing, halogen-free and low-smoke flame retardant and fire resistant wires and cables. 2 Normative References The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding corrigendum), or revisions of, any of these publications do not apply. However, all parties coming to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards. For undated references, the latest edition of the normative document referred to applies. GB/T 17650.2-1998 Test on Gases Evolved during Combustion of Materials from Cables - Part 2: Determination of Degree of Acidity of Gases by Measuring pH and Conductivity (idt IEC 60754-2: 1991) GB/T 17651.2-1998 Measurement of Smoke Density of Cables Burning under Defined Conditions - Part 2: Test Procedure and Requirements (idt IEC 61034-2: 1997) GB/T 18380.1-2001 Tests on Electric Cables under Fire Conditions - Part 1: Test on a Single Vertical Insulated Wire or Cable (idt IEC 60332-1: 1993) GB/T 18380.2-2001 Tests on Electric Cables under Fire Conditions - Part 2: Test on a Single Small Vertical Insulated Copper Wire or Cable (idt IEC 60332-2: 1989) GB/T 18380.3-2001 Tests on Electric Cables under Fire Conditions - Part 3: Test on Bunched Wire or Cable (idt IEC 60332-3: 1992) GB/T 19216.21-2003 Tests for Electric Cables under Fire Conditions - Circuit Integrity - Part 21: Procedures and Requirements - Cable of Rated Voltage up to and Including 0.6/1.0kV (idt IEC 60331-21: 1999) GB/T 19216.23-2003 Tests for Electric Cables under Fire Conditions - Circuit Integrity - Procedures and Requirements - Electric Data Cables (idt IEC 60331-23: 1999) IEC 60332-3-25: 2000 Tests on Electric and Optical Fiber Cables under Fire Conditions - Part 25: Test for Flame Spread of Bunched Wires or Cables - Category D 3 Terms and Definitions 3.1 Flame retardance The characteristic that flame spreads on the sample within limited scope and extinguishes by itself in case the sample is burned under specified test condition and the fire source is removed, i.e. the capacity to retard occurrence or spreading of the flame. 3.2 Fire resistance The capacity to keep continuous operation under specified state in case of being burned under specified fire source and time, i.e. the capacity to maintain integrity of the line. 3.3 Halogen free Free from halogen, relatively low corrosivity of combustion products. 3.4 Low smoke Less smoke dust generated in case of being burned, namely relatively high light transmittance (visibility). 4 Models 4.1 Composition of model The models of flame retardant and fire resistant wires and cables are composed of two parts: codes for combustion characteristics of products and models of relevant wires and cables, see Figure 1. Figure 1 Composition of Models of Flame Retardant and Fire Resistant Wires and Cables 4.2 Codes and sequential arrangement of combustion characteristics 4.2.1 See Table 1 for codes of combustion characteristics. Table 1 Codes of Combustion Characteristics Code Designation Za ZA ZB ZC ZDb Omitted W D U N NJ NS Flame retardance Category A flame retardance Category B flame retardance Category C flame retardance Category D flame retardance Halogen containing Halogen free Low smoke Low toxicity Fire resistance Fire resistance + impact Fire resistance + water jet a Z represents single flame retardance, only used for products with halogen free base materials. For those with halogen containing base materials, Z is omitted. b ZD represents Category D bunched flame retardance, is applicable to the relatively thin products with the outside diameter ≤ 12mm. 4.2.2 See Table 2 for the current codes for combustion characteristics of products. Where various combustion characteristics are required, their codes are arranged in the sequence of halogen free (halogen containing is omitted), low smoke, low toxicity, flame retardance or fire resistance. Table 2 Current Codes for Combustion Characteristics of Products Series designation Code Designation Flame retardance series Halogen containing ZA ZB ZC ZD Category A flame retardance Category B flame retardance Category C flame retardance Category D flame retardance Halogen free, low smoke WDZ WDZA WDZB WDZC WDZD Halogen free, low smoke, flame retardance Category A halogen free, low smoke, flame retardance Category B halogen free, low smoke, flame retardance Category C halogen free, low smoke, flame retardance Category D halogen free, low smoke, flame retardance Fire resistance series Halogen containing N ZAN ZBN ZCN ZDN Fire resistance Category A flame retardance, fire resistance Category B flame retardance, fire resistance Category C flame retardance, fire resistance Category D flame retardance, fire resistance Halogen free, low smoke WDZN WDZAN WDZBN WDZCN WDZDN Halogen free, low smoke, flame retardance, fire resistance Category A halogen free, low smoke, flame retardance and fire resistance Category B halogen free, low smoke, flame retardance and fire resistance Category C halogen free, low smoke, flame retardance and fire resistance Category D halogen free, low smoke, flame retardance and fire resistance Note: Other codes are under consideration. 4.3 Models of wires and cables Models of wires and cables are generally composed of series codes, material codes as well as operating characteristics and structure characteristics. Models of relevant wires and cables are directly adopted in this standard. However, meaning of the following codes is expanded as follows: Y——Polyethylene or polyolefin insulation or sheath; YJ——Cross-linked polyethylene or cross-linked polyolefin insulation or sheath; 3——Polyethylene or polyolefin outer sheath; 4——Cross-linked polyethylene or elastomer outer sheath; 6——Nonmagnetic metal tape armour; 7——Nonmagnetic metal wire armour. 4.4 Expression method of products The products are expressed with "model, specification and serial number of this standard / relevant product standards". See Appendix A for relevant product standards. Example 1: Category A flame-retardant power cable with polyvinyl chloride insulation and polyvinyl chloride sheath is expressed as: ZA-VV Specification (omitted) GB/T 19666-2005/GB/T 12706.1-2002 Example 2: Category B flame-retardant power cable with cross-linked polyethylene insulation and polyvinyl chloride sheath is expressed as: ZB-YJV Specification (omitted) GB/T 19666-2005/GB/T 12706.1-2002 Example 3: Category C flame-retardant and fire-resistant power cable with cross-linked polyethylene insulation and polyvinyl chloride sheath is expressed as: ZCN-YJV Specification (omitted) GB/T 19666-2005/GB/T 12706.1-2002 Example 4: halogen-free, low-smoke and Category B flame-retardant power cable with cross-linked polyethylene insulation and polyolefin sheath is expressed as: WDZB-YJY Specification (omitted) GB/T 19666-2005/GB/T 12706.1-2002 Example 5: Category D flame retardant wires with polyvinyl chloride insulation for fixed wiring is expressed as: ZD-BV Specification (omitted) GB/T 19666-2005/GB 5023.3-1997 Example 6: Category C flame-retardant cable with polyvinyl chloride insulation and light polyvinyl chloride sheath is expressed as: ZC-BVV Specification (omitted) GB/T 19666-2005/GB 5023.4-1997 Example 7: Category A flame-retardant control cable with polyvinyl chloride insulation and steel tape armoring polyvinyl chloride sheath is expressed as: ZA-KVV22 Specification (omitted) GB/T 19666-2005/GB 9330-1988 Example 8: halogen-free, low-smoke and Category B flame-retardant local communication cable with polyolefin insulation, filled moisture-proof layer polyolefin sheath and single-layer vertically wrapped and rolled steel tape armoring polyolefin coat is expressed as: WDZB-HYAT53 Specification (omitted) GB/T 19666-2005/GB/T 13849.2-1993
Contents of GB/T 19666-2005
Foreword I 1 Scope 2 Normative References 3 Terms and Definitions 4 Models 5 Combustion Characteristics Requirements 6 Technical Requirements 7 Acceptance Rules Appendix A (Informative) Examples of Relevant Standards for Wires and Cables Appendix B (Informative) Technical Performance of Halogen-free Low-smoke Flame Retardant Insulation and Sheath Appendix C (Informative) Technical Performance of Fire Resistant Mica Tape for Wires and Cables
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 19666-2005, GB 19666-2005, GBT 19666-2005, GB/T19666-2005, GB/T 19666, GB/T19666, GB19666-2005, GB 19666, GB19666, GBT19666-2005, GBT 19666, GBT19666