2025-7-15 18.97.9.168
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 18380.22-2008
GB/T 18380.22-2008   Tests on electric and optical fibre cables under fire conditions - Part 22: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion (English Version)
Standard No.: GB/T 18380.22-2008 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 3000 words Price(USD):60.0 remind me the price change

Email:

Implemented on:2009-4-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 18380.22-2008
English Name: Tests on electric and optical fibre cables under fire conditions - Part 22: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion
Chinese Name: 电缆和光缆在火焰条件下的燃烧试验 第22部分:单根绝缘细电线电缆火焰垂直蔓延试验 扩散型火焰试验方法
Chinese Classification: K13    Cable and its accessory
Professional Classification: GB    National Standard
ICS Classification: 29.060.20 29.060.20    Cables 29.060.20
Issued by: AQSIQ; SAC
Issued on: 2008-6-26
Implemented on: 2009-4-1
Status: valid
Language: English
File Format: PDF
Word Count: 3000 words
Price(USD): 60.0
Delivery: via email in 1 business day
1 Scope This part of GB/T 18380 specifies the procedure for testing the resistance to vertical flame propagation for a single small vertical electrical insulated conductor or cable, or optical cable, under fire conditions. The apparatus is given in GB/T 18380.21-2008. This standard gives the procedure for testing small optical fibre cables or a small insulated conductor or cable when the method specified in GB/T 18380.12-2008 is not suitable because some small optical fibre cables may break or small conductors may melt during the application of the flame. The recommended range of application is for the testing of small single insulated conductors or cables of less than 0.5mm² cross-section. Note: Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that wherever the risk of propagation is high, for example, in long vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the test sample of cable complies with the performance requirements recommended in this standard, that a bunch of cables will behave in a similar manner. (See GB/T 18380.31~36. serious.) Recommended requirements for performance are given in Annex A. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of GB/T 18380. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 16499-1996 Guide to the Drafting of Electrical Safety Standards (eqv IEC Guide 104:1984) GB/T 18380.21-2008 Tests on Electric and Optical Fibre Cables under Fire Conditions - Part 21: Test for Vertical Flame Propagation for a Single Small Insulated Wire or Cable – Apparatus (IEC 60332-2-1:2004, IDT) IEC 60695-4:1993 Fire Hazard Testing – Part 4: Terminology Concerning Fire Tests 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. The terms and definitions are taken from GB/T 18380. 3.1 ignition source source of energy that initiates combustion
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Test Apparatus 5 Test Procedure 6 Evaluation of Test Results Annex A (Informative) Recommended Performance Requirements
GB/T 18380.22-2008 is referred in:
*JB/T 8734.1-2016 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V — Part 1:General requirements
*JB/T 8734.2-2016 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V — Part 2:Insulated cables and wires for fixed wiring
*JB/T 8734.5-2016 Polyvinyl chloride insulated cables and wires and cords of rated voltages up to and including 450/750V — Part 5: Screened wires
*GB/T 19666-2019 General rules for flame retardant and fire resistant electric wires and cables or optical fiber cables
*TB/T 1484.3-2017 Specification for cables on board rolling stock-Part 3:Cables for communication networks
*GB 17761-2024 Safety technical specification for electric bicycle
*GB/T 42236.1-2022 Electric bicycles centralized charging facilities—Part 1: Technical specification
Code of China
Standard
GB/T 18380.22-2008  Tests on electric and optical fibre cables under fire conditions - Part 22: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion (English Version)
Standard No.GB/T 18380.22-2008
Statusvalid
LanguageEnglish
File FormatPDF
Word Count3000 words
Price(USD)60.0
Implemented on2009-4-1
Deliveryvia email in 1 business day
Detail of GB/T 18380.22-2008
Standard No.
GB/T 18380.22-2008
English Name
Tests on electric and optical fibre cables under fire conditions - Part 22: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion
Chinese Name
电缆和光缆在火焰条件下的燃烧试验 第22部分:单根绝缘细电线电缆火焰垂直蔓延试验 扩散型火焰试验方法
Chinese Classification
K13
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2008-6-26
Implemented on
2009-4-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
3000 words
Price(USD)
60.0
Keywords
GB/T 18380.22-2008, GB 18380.22-2008, GBT 18380.22-2008, GB/T18380.22-2008, GB/T 18380.22, GB/T18380.22, GB18380.22-2008, GB 18380.22, GB18380.22, GBT18380.22-2008, GBT 18380.22, GBT18380.22
Introduction of GB/T 18380.22-2008
1 Scope This part of GB/T 18380 specifies the procedure for testing the resistance to vertical flame propagation for a single small vertical electrical insulated conductor or cable, or optical cable, under fire conditions. The apparatus is given in GB/T 18380.21-2008. This standard gives the procedure for testing small optical fibre cables or a small insulated conductor or cable when the method specified in GB/T 18380.12-2008 is not suitable because some small optical fibre cables may break or small conductors may melt during the application of the flame. The recommended range of application is for the testing of small single insulated conductors or cables of less than 0.5mm² cross-section. Note: Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that wherever the risk of propagation is high, for example, in long vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the test sample of cable complies with the performance requirements recommended in this standard, that a bunch of cables will behave in a similar manner. (See GB/T 18380.31~36. serious.) Recommended requirements for performance are given in Annex A. 2 Normative References The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of GB/T 18380. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies. GB/T 16499-1996 Guide to the Drafting of Electrical Safety Standards (eqv IEC Guide 104:1984) GB/T 18380.21-2008 Tests on Electric and Optical Fibre Cables under Fire Conditions - Part 21: Test for Vertical Flame Propagation for a Single Small Insulated Wire or Cable – Apparatus (IEC 60332-2-1:2004, IDT) IEC 60695-4:1993 Fire Hazard Testing – Part 4: Terminology Concerning Fire Tests 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. The terms and definitions are taken from GB/T 18380. 3.1 ignition source source of energy that initiates combustion
Contents of GB/T 18380.22-2008
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Test Apparatus 5 Test Procedure 6 Evaluation of Test Results Annex A (Informative) Recommended Performance Requirements
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 18380.22-2008, GB 18380.22-2008, GBT 18380.22-2008, GB/T18380.22-2008, GB/T 18380.22, GB/T18380.22, GB18380.22-2008, GB 18380.22, GB18380.22, GBT18380.22-2008, GBT 18380.22, GBT18380.22