2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 19862-2005
GB/T 19862-2005   General requirements for monitoring equipments of power quality (English Version)
Standard No.: GB/T 19862-2005 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 5000 words Translation Price(USD):120.0 remind me the price change

Email:

Implemented on:2006-4-1 Delivery: via email in 1 business day

→ → →

,2017-3-1,2006-4-1,1411381818096605F1C1769A79FF2
Standard No.: GB/T 19862-2005
English Name: General requirements for monitoring equipments of power quality
Chinese Name: 电能质量监测设备通用要求
Chinese Classification: F20    
Professional Classification: GB    National Standard
ICS Classification: 17.220.20 17.220.20    Measurement of electrical and magnetic quantities 17.220.20
Source Content Issued by: AQSIQ; SAC
Issued on: 2005-7-29
Implemented on: 2006-4-1
Status: superseded
Superseded by:GB/T 19862-2016 General requirements for monitoring equipments of power quality
Superseded on:2017-3-1
Target Language: English
File Format: PDF
Word Count: 5000 words
Translation Price(USD): 120.0
Delivery: via email in 1 business day
1 Scope This standard specifies the general requirements for monitoring equipments of power quality. This standard is applicable to the following indoor equipments monitoring the power quality of AC power systems and their equipments. ——Stationary monitoring equipment; ——Portable monitoring equipment. 2 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards. For undated references, the latest edition of the normative document referred to applies. GB/T 191-2000 Packaging - Pictorial Marking for Handling of Goods (eqv ISO 780: 1997) GB/T 2423.1-2001 Environmental Testing for Electric and Electronic Products-Part 2: Test Method-Test A: Low Temperature (idt IEC60068-2-1: 1990) GB/T 2423.2-2001 Environmental Testing for Electric and Electronic Products-Part 2: Test Method-Test B: High Temperature (idt IEC60068-2-2: 1974) GB/T 2423.4-1993 Basic Environmental Testing Procedures for Electric and Electronic Products-Test Db: Damp Heat, Cyclic (eqv IEC68-2-30: 1980) GB/T 2423.5-1995 Environmental Testing for Electric and Electronic Products-Part 2: Test Method Test Ea and Guidance: Impact (idt IEC 60068-2-27: 1987) GB/T 2423.10-1995 Environmental Testing for Electric and Electronic Products-Part 2: Tests methods-Test Fc and Guidance: Vibration (Sinusoidal) (idt IEC 682-6: 1982) GB/T 2829-2002 Sampling Procedures and Tables for Periodic Inspection by Attributes (Apply to Inspection of Process Stability) GB 4208-1993 Degrees of Protection Provided by Enclosure (IP Code) (eqv IEC 60529: 1989) GB/T 12325-2003 Power Quality-Admissible Deviation of Supply Voltage GB 12326-2000 Power Quality-Voltage Fluctuation and Flicker GB/T 14549-1993 Quality of Electric Energy Supply-Harmonics in Public Supply Network GB/T 15543-1995 Quality of Electric Energy Supply-Admissible Three-phase Voltage Unbalance Factor GB/T 15945-1995 Quality of Electric Energy Supply Permissible Deviation of Frequency for Power System GB 17625.1-2003 Electromagnetic Compatibility-Limits-Limits for Harmonic Current Emissions (Equipment Input Current≤16A per Phase) (IEC 61000-3-2: 2001, IDT) GB/T 17626.2-1998 Electromagnetic Compatibility -Testing and Measurement Techniques-Electrostatic Discharge Immunity Test (idt IEC 61000-4-2: 1995) GB/T 17626.3-1998 Electromagnetic Compatibility-Testing and Measurement Techniques-Radiated Radio-frequency Electromagnetic Field Immunity Test (idt IEC61000-4-3: 1995) GB/T 17626.4-1998 Electromagnetic Compatibility-Testing and Measurement Techniques-Electrical Fast Transient/Burst Immunity Test (idt IEC61000-4-4: 1995) GB/T 17626.5-1999 Electromagnetic Compatibility-Testing and Measurement Techniques-Surge (Impact) Immunity Test (idt IEC 61000-4-5: 1995) GB/T 17626.11-1999 Electromagnetic Compatibility-Testing and Measurement Techniques-Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests (idt IEC 61000-4-11: 1994) 3 Terms and Definitions For the purposes of this standard, the following terms and definitions apply. 3.1 Voltage deviation Deviation of the power supply voltage to the nominal voltage Voltage deviation (%)= ×100 [GB/T 12325-2003, 3.4] 3.2 Frequency deviation It refers to the difference of actual value and nominal value of system frequency. [GB/T 15945-1995, 2.1] 3.3 Harmonic It refers to the component with a frequency one integral multiple greater than the fundamental frequency and obtained by decomposing the fourier series of periodic alternating current component. [GB/T 14549-1993, 3.4] 3.4 Voltage fluctuation It refers to a series of changes or continuous changes for voltage root mean square value. [GB 12326-2000, 3.8] 3.5 Flicker It refers to the visual sense caused by instable lighting illumination. [GB l2326-2000, 3.9] 3.6 Unbalance factor Unblanced degree of three-phase in the three-phase power system and shall be represented by root mean square value percentage of negative sequence component and positive sequence component of voltage or current. [GB/T l5543-1995, 2.1]
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Composition 4.1 Classification 4.2 Equipment Composition 5 Technical Requirements 5.1 Fundamental Function Requirements 5.2 Accuracy Requirements 5.3 Electrical Performance Requirements 5.4 Regular Service Conditions 5.5 Shell and Mechanical Performance 5.6 Safety Performance 5.7 Electromagnetic Compatibility (EMC) 6 Test Methods 6.1 Test Conditions 6.2 Fundamental Function Inspection 6.3 Accuracy Test Method 6.4 Electrical Performance Test 6.5 Climatic Protection Test 6.6 Shell and Mechanical Performance Test 6.7 Safety Performance Test 6.8 Electromagnetic Compatibility Test 7 Inspection Rules 7.1 Delivery Inspection 7.2 Type Test 7.3 Sampling Plan of Type Test 7.4 Nonconformity Classification 7.5 Nonconformity Judgment 7.6 Inspection Item 8 Marking, Packaging, Transportation and Storage 8.1 Marking 8.2 Packaging 8.3 Transportation and Storage
Referred in GB/T 19862-2005:
*GB/T 191-2000 Packaging - Pictorial marking for handling of goods
*GB/T 2423.1-2001 Environmental testing for electric and electronic and electronic products--Part 2:Test methods--Tests A:Cold
*GB/T 2423.2-2001 Environmental testing for electric and electronic products--Part 2:Test methods--Tests B:Dry heat
*GB/T 2423.4-1993 Basic environmental testing procedures for electric and electronic products-Test Db: Damp heat, cyclic
*GB/T 2423.5-1995 Environmental testing for electric and electronic products Part 2:Test methods Test Ea and guidance:Shock
*GB/T 2423.10-1995 Environmental testing for electric and electronic products-Part 2: Test methods Test Fc and guidance: Vibration (Sinusoidal)
*GB/T 2829-2002 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability)
*GB 4208-1993 Degrees of protection provided by enclosure (IP code)
*GB/T 12325-2003 Power quality--Admissible deviation of supply voltage
*GB 12326-2000 Power quality--Voltage fluctuation and flicker
*GB/T 14549-1993 Quality of Electric Energy Supply - Harmonics in Public Supply Network
*GB/T 15543-1995 Quality of electric energy supply-Admissible three-phase voltage unbalance factor
*GB/T 15945-1995 Quality of electric energy supply Permissible deviation of frequency for power system
*GB 17625.1-2003 Electromagnetic compatibility—Limits—Limits for harmonic current emissions(equipment input current≤16A per phase)
*GB/T 17626.2-1998 Electromagnetic compatibility--Testing and measurement techniques--Electrostatic discharge immunity test
*GB/T 17626.3-1998 Electromagnetic compatibility--Testing and measurement techniques-- Radiated,radio-frequency,electromagnetic field immunity test
*GB/T 17626.4-1998 Electromagnetic compatibility-- Testing and measurement techniques --Electrical fast transient/burst immunity test
*GB/T 17626.5-1999 Electromagnetic compatibility--Testing and measurement techniques--Surge immunity test
*GB/T 17626.11-1999 Electromagnetic compatibility Testing and measurement techniques Voltage dips,short interruptions and voltage variations immunity tests
GB/T 19862-2005 is referred in:
* GB/T 30137-2013 Power Quality - Voltage Dips and Short Interruptions
* GB/T 30137-2013 Power Quality - Voltage Dips and Short Interruptions
* GB/T 30137-2013 Power Quality - Voltage Dips and Short Interruptions
*DL/T 1028-2006 Verification code for power quality analyzer
Code of China
Standard
GB/T 19862-2005  General requirements for monitoring equipments of power quality (English Version)
Standard No.GB/T 19862-2005
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count5000 words
Price(USD)120.0
Implemented on2006-4-1
Deliveryvia email in 1 business day
Detail of GB/T 19862-2005
Standard No.
GB/T 19862-2005
English Name
General requirements for monitoring equipments of power quality
Chinese Name
电能质量监测设备通用要求
Chinese Classification
F20
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2005-7-29
Implemented on
2006-4-1
Status
superseded
Superseded by
GB/T 19862-2016 General requirements for monitoring equipments of power quality
Superseded on
2017-3-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
5000 words
Price(USD)
120.0
Keywords
GB/T 19862-2005, GB 19862-2005, GBT 19862-2005, GB/T19862-2005, GB/T 19862, GB/T19862, GB19862-2005, GB 19862, GB19862, GBT19862-2005, GBT 19862, GBT19862
Introduction of GB/T 19862-2005
1 Scope This standard specifies the general requirements for monitoring equipments of power quality. This standard is applicable to the following indoor equipments monitoring the power quality of AC power systems and their equipments. ——Stationary monitoring equipment; ——Portable monitoring equipment. 2 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the standards. For undated references, the latest edition of the normative document referred to applies. GB/T 191-2000 Packaging - Pictorial Marking for Handling of Goods (eqv ISO 780: 1997) GB/T 2423.1-2001 Environmental Testing for Electric and Electronic Products-Part 2: Test Method-Test A: Low Temperature (idt IEC60068-2-1: 1990) GB/T 2423.2-2001 Environmental Testing for Electric and Electronic Products-Part 2: Test Method-Test B: High Temperature (idt IEC60068-2-2: 1974) GB/T 2423.4-1993 Basic Environmental Testing Procedures for Electric and Electronic Products-Test Db: Damp Heat, Cyclic (eqv IEC68-2-30: 1980) GB/T 2423.5-1995 Environmental Testing for Electric and Electronic Products-Part 2: Test Method Test Ea and Guidance: Impact (idt IEC 60068-2-27: 1987) GB/T 2423.10-1995 Environmental Testing for Electric and Electronic Products-Part 2: Tests methods-Test Fc and Guidance: Vibration (Sinusoidal) (idt IEC 682-6: 1982) GB/T 2829-2002 Sampling Procedures and Tables for Periodic Inspection by Attributes (Apply to Inspection of Process Stability) GB 4208-1993 Degrees of Protection Provided by Enclosure (IP Code) (eqv IEC 60529: 1989) GB/T 12325-2003 Power Quality-Admissible Deviation of Supply Voltage GB 12326-2000 Power Quality-Voltage Fluctuation and Flicker GB/T 14549-1993 Quality of Electric Energy Supply-Harmonics in Public Supply Network GB/T 15543-1995 Quality of Electric Energy Supply-Admissible Three-phase Voltage Unbalance Factor GB/T 15945-1995 Quality of Electric Energy Supply Permissible Deviation of Frequency for Power System GB 17625.1-2003 Electromagnetic Compatibility-Limits-Limits for Harmonic Current Emissions (Equipment Input Current≤16A per Phase) (IEC 61000-3-2: 2001, IDT) GB/T 17626.2-1998 Electromagnetic Compatibility -Testing and Measurement Techniques-Electrostatic Discharge Immunity Test (idt IEC 61000-4-2: 1995) GB/T 17626.3-1998 Electromagnetic Compatibility-Testing and Measurement Techniques-Radiated Radio-frequency Electromagnetic Field Immunity Test (idt IEC61000-4-3: 1995) GB/T 17626.4-1998 Electromagnetic Compatibility-Testing and Measurement Techniques-Electrical Fast Transient/Burst Immunity Test (idt IEC61000-4-4: 1995) GB/T 17626.5-1999 Electromagnetic Compatibility-Testing and Measurement Techniques-Surge (Impact) Immunity Test (idt IEC 61000-4-5: 1995) GB/T 17626.11-1999 Electromagnetic Compatibility-Testing and Measurement Techniques-Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests (idt IEC 61000-4-11: 1994) 3 Terms and Definitions For the purposes of this standard, the following terms and definitions apply. 3.1 Voltage deviation Deviation of the power supply voltage to the nominal voltage Voltage deviation (%)= ×100 [GB/T 12325-2003, 3.4] 3.2 Frequency deviation It refers to the difference of actual value and nominal value of system frequency. [GB/T 15945-1995, 2.1] 3.3 Harmonic It refers to the component with a frequency one integral multiple greater than the fundamental frequency and obtained by decomposing the fourier series of periodic alternating current component. [GB/T 14549-1993, 3.4] 3.4 Voltage fluctuation It refers to a series of changes or continuous changes for voltage root mean square value. [GB 12326-2000, 3.8] 3.5 Flicker It refers to the visual sense caused by instable lighting illumination. [GB l2326-2000, 3.9] 3.6 Unbalance factor Unblanced degree of three-phase in the three-phase power system and shall be represented by root mean square value percentage of negative sequence component and positive sequence component of voltage or current. [GB/T l5543-1995, 2.1]
Contents of GB/T 19862-2005
Foreword i 1 Scope 2 Normative References 3 Terms and Definitions 4 Classification and Composition 4.1 Classification 4.2 Equipment Composition 5 Technical Requirements 5.1 Fundamental Function Requirements 5.2 Accuracy Requirements 5.3 Electrical Performance Requirements 5.4 Regular Service Conditions 5.5 Shell and Mechanical Performance 5.6 Safety Performance 5.7 Electromagnetic Compatibility (EMC) 6 Test Methods 6.1 Test Conditions 6.2 Fundamental Function Inspection 6.3 Accuracy Test Method 6.4 Electrical Performance Test 6.5 Climatic Protection Test 6.6 Shell and Mechanical Performance Test 6.7 Safety Performance Test 6.8 Electromagnetic Compatibility Test 7 Inspection Rules 7.1 Delivery Inspection 7.2 Type Test 7.3 Sampling Plan of Type Test 7.4 Nonconformity Classification 7.5 Nonconformity Judgment 7.6 Inspection Item 8 Marking, Packaging, Transportation and Storage 8.1 Marking 8.2 Packaging 8.3 Transportation and Storage
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 19862-2005, GB 19862-2005, GBT 19862-2005, GB/T19862-2005, GB/T 19862, GB/T19862, GB19862-2005, GB 19862, GB19862, GBT19862-2005, GBT 19862, GBT19862