2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 30137-2013
GB/T 30137-2013   Power Quality - Voltage Dips and Short Interruptions (English Version)
Standard No.: GB/T 30137-2013 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 6000 words Translation Price(USD):150.0 remind me the price change

Email:

Implemented on:2014-5-10 Delivery: via email in 1 business day

→ → →

,2025-4-1,2014-5-10,14113818230062F1A30CADA4E8A5D
Standard No.: GB/T 30137-2013
English Name: Power Quality - Voltage Dips and Short Interruptions
Chinese Name: 电能质量 电压暂降与短时中断
Chinese Classification: K04    Basic standards and general methods
Professional Classification: GB    National Standard
Source Content Issued by: AQSIQ;SAC
Issued on: 2013-12-17
Implemented on: 2014-5-10
Status: superseded
Superseded by:GB/T 30137-2024
Superseded on:2025-4-1
Target Language: English
File Format: PDF
Word Count: 6000 words
Translation Price(USD): 150.0
Delivery: via email in 1 business day
1 Scope This Standard specifies the indexes as well as testing, statistics and assessment methods of voltage dip and short interruption. This Standard is applicable to AC 50Hz power system. 2 Normative References The following documents are indispensable for the application of this Standard. For dated reference, only the dated edition applies. For undated reference, the latest edition (including all amendments) applies. GB/T 19862 General Requirements for Power Quality Monitoring Equipment 3 Terminologies and Definitions For the purposes of this document, the following terminologies and definitions apply. 3.1 Voltage dip (sag) It refers to the phenomenon that the power frequency voltage’s root mean square (RMS) of some point in the power system suddenly drops to 0.1p.u~0.9p.u, and returns to normal after temporarily sustaining for 10ms~1min.
Foreword I 1 Scope 2 Normative References 3 Terminologies and Definitions 4 Statistics and Recommended Indexes of Voltage Dip and Short Interruption Events 5 Detection of Voltage Dip and Short Interruption 6 Monitoring of voltage dip and short interruption 7 Assessment of Voltage Dip and Short Interruption Appendix A (Informative) Tolerance Curve Appendix B (Informative) Critical Distance and Dip Areas Bibliography
Referred in GB/T 30137-2013:
* GB/T 19862-2005 General requirements for monitoring equipments of power quality
GB/T 30137-2013 is referred in:
* Q/GDW 1650.2-2014 Technical specification of power quality monitoring Part 2: Power quality monitoring device
* Q/GDW 1650.1-2014 Technical specification of power quality monitoring Part 1: Power quality monitoring master station
Code of China
Standard
GB/T 30137-2013  Power Quality - Voltage Dips and Short Interruptions (English Version)
Standard No.GB/T 30137-2013
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)150.0
Implemented on2014-5-10
Deliveryvia email in 1 business day
Detail of GB/T 30137-2013
Standard No.
GB/T 30137-2013
English Name
Power Quality - Voltage Dips and Short Interruptions
Chinese Name
电能质量 电压暂降与短时中断
Chinese Classification
K04
Professional Classification
GB
ICS Classification
Issued by
AQSIQ;SAC
Issued on
2013-12-17
Implemented on
2014-5-10
Status
superseded
Superseded by
GB/T 30137-2024
Superseded on
2025-4-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
150.0
Keywords
GB/T 30137-2013, GB 30137-2013, GBT 30137-2013, GB/T30137-2013, GB/T 30137, GB/T30137, GB30137-2013, GB 30137, GB30137, GBT30137-2013, GBT 30137, GBT30137
Introduction of GB/T 30137-2013
1 Scope This Standard specifies the indexes as well as testing, statistics and assessment methods of voltage dip and short interruption. This Standard is applicable to AC 50Hz power system. 2 Normative References The following documents are indispensable for the application of this Standard. For dated reference, only the dated edition applies. For undated reference, the latest edition (including all amendments) applies. GB/T 19862 General Requirements for Power Quality Monitoring Equipment 3 Terminologies and Definitions For the purposes of this document, the following terminologies and definitions apply. 3.1 Voltage dip (sag) It refers to the phenomenon that the power frequency voltage’s root mean square (RMS) of some point in the power system suddenly drops to 0.1p.u~0.9p.u, and returns to normal after temporarily sustaining for 10ms~1min.
Contents of GB/T 30137-2013
Foreword I 1 Scope 2 Normative References 3 Terminologies and Definitions 4 Statistics and Recommended Indexes of Voltage Dip and Short Interruption Events 5 Detection of Voltage Dip and Short Interruption 6 Monitoring of voltage dip and short interruption 7 Assessment of Voltage Dip and Short Interruption Appendix A (Informative) Tolerance Curve Appendix B (Informative) Critical Distance and Dip Areas Bibliography