2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 33629-2017
GB/T 33629-2017   Wind turbine generator systems — Lightning protection (English Version)
Standard No.: GB/T 33629-2017 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 56500 words Translation Price(USD):1690.0 remind me the price change

Email:

Implemented on:2017-12-1 Delivery: via email in 1 business day

→ → →

,2025-4-1,2017-12-1,7131ED0DDBA78B951497865719350
Standard No.: GB/T 33629-2017
English Name: Wind turbine generator systems — Lightning protection
Chinese Name: 风力发电机组 雷电保护
Professional Classification: GB    National Standard
Source Content Issued by: MOHURD; AQSIQ
Issued on: 2017-05-12
Implemented on: 2017-12-1
Status: superseded
Superseded by:GB/T 33629-2024
Superseded on:2025-4-1
Target Language: English
File Format: PDF
Word Count: 56500 words
Translation Price(USD): 1690.0
Delivery: via email in 1 business day
Wind turbine generator systems — Lightning protection 1 Scope This standard applies to lightning protection of wind turbine generators and components systems. Normative references are made to generic standards for lightning protection, low-voltage systems and high-voltage systems for machinery and installations and electromagnetic compatibility (EMC). This standard defines the lightning environment for wind turbines and application of the environment for risk assessment for the wind turbine. It defines requirements for protection of blades, other structural components and electrical and control systems against both direct and indirect effects of lightning . Test methods to validate compliance are recommended. Guidance and the use of applicable lightning protection, industrial electrical and EMC standards including earthing is provided. Guidance regarding personal safety is provided. Guidelines for damage statistics and reporting are provided. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 16895.22-2004 Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Section 534: Devices for protection against overvoltages [IEC 60364-5-53: 2001 A1: 2002 [ There is an integrated version 3.1 (2002) that includes IEC 60364-5-53 (2001) and its revision 1 (2002).] , IDT] IEC 60060-1: 1989 High-voltage test techniques - Part 1: General definitions and test requirements) IEC 60068 (all parts) Environmental testing IEC 60071 (all parts) Insulation Co-ordination IEC 60071-2:1996 Insulation Co-ordination - Part 2: Application guide IEC 60099-4 Surge arresters — Part 4: Metal-oxide surge arresters without gaps for a.c. systems IEC 60099-5 Surge arresters — Part 5: Selection and application recommendations IEC 60204-1 Safety of machinery — Electrical equipment of machines — Part 1. General requirements IEC 60204-11 Safety of machinery — Electrical equipment of machines — Part 11: Requirements for HV equipment for voltages above 1000 V a.c. or 1500 V d.c. and not exceeding 36 kV IEC 60243-1 Electrical strength of insulating materials — Test methods — Part 1: Tests at power frequencies IEC 60243-3 Electric strength of solid insulating malaria/s — Test methods — Part 3: Additional requirements for 1,2/50 μs impulse tests IEC 60364-4-44 Low-voltage electrical installations — Part 4-44: Protection for safety — Protection against voltage disturbances and electromagnetic disturbances IEC 60464-2 Varnishes used for electric at insulation — Part 2: Methods of test IEC/TS 60479-1 Effects of current on human beings and livestock — Part 1: General aspects IEC 60479-4 Effects of current on human beings and livestock — Part 4: Effects of lightning strokes on human beings and livestock IEC 60587 Electrical Insulating materials used under severe ambient conditions — Test methods for evaluating resistance to tracking and erosion IEC 60664-1 Insulation coordination for equipment within low-voltage systems — Part 1: Principles, requirements and tests IEC 61000-4-5 Electromagnetic compatibility (EMC) — Part 4-5: testing and measurement techniques — Surge immunity test IEC/TR 61000-5-2 Electromagnetic compatibility (EMC) — Part 5: Installation and mitigation guidelines — Section 2: Earthing and cabling IEC/TO 61400-23 Wind turbine generator systems — Part 23: Full-scale structural testing of rotor blades IEC 61643-1 Low-voltage surge protective devices — Part 1: Surge protective devices connected to low-voltage power distribution systems — Requirements and tests IEC 61643-12 Low-voltage surge protective devices — Part 12: Surge protective devices connected to low-voltage power distribution systems — Selection and application principles IEC 61643-21 Low voltage surge protective devices — Part 21: Surge protective devices connected to telecommunications and signalling networks — Performance requirements and testing methods IEC 61643-22 Low-voltage surge protective devices — Part 22: Surge protective devices connected to telecommunications and signalling networks — Selection and application principles IEC 62153-4-3 Metallic communication cable test methods — Part 4-3: Electromagnetic compatibility (EMC) — Surface transfer impedance — Triaxial method IEC 62305-1:2006 Protection against lightning — Part 1: General principles IEC 62305-2:2006 Protection against lightning — Part 2: Risk management IEC 62305-3:2006 Protection against lightning — Part 3: Physical damage to structures and life hazard IEC 62305-4:2006 Protection against lightning — Part 4: Electric at and electronic systems within structures EN 50164-1 Lightning Protection Components (LPC) — Part 1: Requirements for connection components CLC HD 637 S1 Power Installations exceeding 1kV A.C. ITU-T K.2 Resistibility of telecommunication equipment installed in a telecommunications centre to overvoltages and overcurrents ITU-T K.21 Resistibility of telecommunications equipment installed in customer premises to overvoltages and overcurrents ITU-T K.46 Protection of telecommunication lines using metallic symmetric conductors against lightning-induced surges 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 air-termination system part of an external LPS using metallic elements such as rods, mesh conductors or catenary wires intended to intercept lightning flashes. 3.2 average steepness of the front of short stroke current The average rate of change of current in a time period △t = t2 - t1. Note: It is expressed by the difference Δi = i(t 2 ) – i(t 1 ) of the values of the current at the start and at the end of this interval, divided by the time interval Δt = t 2 – t 1 (see Figure A.3). 3.3 bonding bar buses. bar on which metal installations, electric power lines, telecommunication lines and other cables can be bonded to an LPS.
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Symbols and units 5 Abbreviations 6 Lightning environment of wind turbines 7 Lightning exposure assessment 8 Lightning protection of subcomponents 9 Earthing of wind turbines and wind farms 10 Personnel safety 11 Documentation of lightning protection system 12 Inspection of lightning protection system Annex A (informative) The lightning phenomenon in relation to wind turbine generator systems Annex B (informative) Lightning exposure assessment Annex C (Informative) Protection methods for blades Annex D (Informative) Test specification Annex E (Informative) Application of lightning protection zones (LPZ) concept at a wind turbine Annex F (Informative) Selection and installation of a coordinated SPD protection in wind turbines Annex G (Informative) Additional information on bonding and shielding and installation technique Annex H (Informative) Testing methods for system level immunity tests Annex I (Informative) Earth termination system Annex J (Informative) Example of defined measuring points Annex K (Informative) Typical lightning damage questionnaire Annex L (Informative) Monitoring systems Annex M (Informative) Guidelines for small wind turbines - Microgeneration Bibliography
Referred in GB/T 33629-2017:
*GBT16895.22-2004
GB/T 33629-2017 is referred in:
*GB/T 30240.6-2017 Guidelines for the use of English in public service areas- Part 6:Education
*GB/T 30240.5-2017 Guidelines for the use of English in public service areas- Part 5:Sports
*GB/T 30240.4-2017 Guidelines for the use of English in public service areas- Part 4:Culture and entertainment
*GB/T 30240.3-2017 Guidelines for the use of English in public service areas- Part 3:Tourism
*GB/T 30240.2-2017 Guidelines for the use of English in public service areas- Part 2:Transportation
Code of China
Standard
GB/T 33629-2017  Wind turbine generator systems — Lightning protection (English Version)
Standard No.GB/T 33629-2017
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count56500 words
Price(USD)1690.0
Implemented on2017-12-1
Deliveryvia email in 1 business day
Detail of GB/T 33629-2017
Standard No.
GB/T 33629-2017
English Name
Wind turbine generator systems — Lightning protection
Chinese Name
风力发电机组 雷电保护
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
MOHURD; AQSIQ
Issued on
2017-05-12
Implemented on
2017-12-1
Status
superseded
Superseded by
GB/T 33629-2024
Superseded on
2025-4-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
56500 words
Price(USD)
1690.0
Keywords
GB/T 33629-2017, GB 33629-2017, GBT 33629-2017, GB/T33629-2017, GB/T 33629, GB/T33629, GB33629-2017, GB 33629, GB33629, GBT33629-2017, GBT 33629, GBT33629
Introduction of GB/T 33629-2017
Wind turbine generator systems — Lightning protection 1 Scope This standard applies to lightning protection of wind turbine generators and components systems. Normative references are made to generic standards for lightning protection, low-voltage systems and high-voltage systems for machinery and installations and electromagnetic compatibility (EMC). This standard defines the lightning environment for wind turbines and application of the environment for risk assessment for the wind turbine. It defines requirements for protection of blades, other structural components and electrical and control systems against both direct and indirect effects of lightning . Test methods to validate compliance are recommended. Guidance and the use of applicable lightning protection, industrial electrical and EMC standards including earthing is provided. Guidance regarding personal safety is provided. Guidelines for damage statistics and reporting are provided. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 16895.22-2004 Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Section 534: Devices for protection against overvoltages [IEC 60364-5-53: 2001 A1: 2002 [ There is an integrated version 3.1 (2002) that includes IEC 60364-5-53 (2001) and its revision 1 (2002).] , IDT] IEC 60060-1: 1989 High-voltage test techniques - Part 1: General definitions and test requirements) IEC 60068 (all parts) Environmental testing IEC 60071 (all parts) Insulation Co-ordination IEC 60071-2:1996 Insulation Co-ordination - Part 2: Application guide IEC 60099-4 Surge arresters — Part 4: Metal-oxide surge arresters without gaps for a.c. systems IEC 60099-5 Surge arresters — Part 5: Selection and application recommendations IEC 60204-1 Safety of machinery — Electrical equipment of machines — Part 1. General requirements IEC 60204-11 Safety of machinery — Electrical equipment of machines — Part 11: Requirements for HV equipment for voltages above 1000 V a.c. or 1500 V d.c. and not exceeding 36 kV IEC 60243-1 Electrical strength of insulating materials — Test methods — Part 1: Tests at power frequencies IEC 60243-3 Electric strength of solid insulating malaria/s — Test methods — Part 3: Additional requirements for 1,2/50 μs impulse tests IEC 60364-4-44 Low-voltage electrical installations — Part 4-44: Protection for safety — Protection against voltage disturbances and electromagnetic disturbances IEC 60464-2 Varnishes used for electric at insulation — Part 2: Methods of test IEC/TS 60479-1 Effects of current on human beings and livestock — Part 1: General aspects IEC 60479-4 Effects of current on human beings and livestock — Part 4: Effects of lightning strokes on human beings and livestock IEC 60587 Electrical Insulating materials used under severe ambient conditions — Test methods for evaluating resistance to tracking and erosion IEC 60664-1 Insulation coordination for equipment within low-voltage systems — Part 1: Principles, requirements and tests IEC 61000-4-5 Electromagnetic compatibility (EMC) — Part 4-5: testing and measurement techniques — Surge immunity test IEC/TR 61000-5-2 Electromagnetic compatibility (EMC) — Part 5: Installation and mitigation guidelines — Section 2: Earthing and cabling IEC/TO 61400-23 Wind turbine generator systems — Part 23: Full-scale structural testing of rotor blades IEC 61643-1 Low-voltage surge protective devices — Part 1: Surge protective devices connected to low-voltage power distribution systems — Requirements and tests IEC 61643-12 Low-voltage surge protective devices — Part 12: Surge protective devices connected to low-voltage power distribution systems — Selection and application principles IEC 61643-21 Low voltage surge protective devices — Part 21: Surge protective devices connected to telecommunications and signalling networks — Performance requirements and testing methods IEC 61643-22 Low-voltage surge protective devices — Part 22: Surge protective devices connected to telecommunications and signalling networks — Selection and application principles IEC 62153-4-3 Metallic communication cable test methods — Part 4-3: Electromagnetic compatibility (EMC) — Surface transfer impedance — Triaxial method IEC 62305-1:2006 Protection against lightning — Part 1: General principles IEC 62305-2:2006 Protection against lightning — Part 2: Risk management IEC 62305-3:2006 Protection against lightning — Part 3: Physical damage to structures and life hazard IEC 62305-4:2006 Protection against lightning — Part 4: Electric at and electronic systems within structures EN 50164-1 Lightning Protection Components (LPC) — Part 1: Requirements for connection components CLC HD 637 S1 Power Installations exceeding 1kV A.C. ITU-T K.2 Resistibility of telecommunication equipment installed in a telecommunications centre to overvoltages and overcurrents ITU-T K.21 Resistibility of telecommunications equipment installed in customer premises to overvoltages and overcurrents ITU-T K.46 Protection of telecommunication lines using metallic symmetric conductors against lightning-induced surges 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 air-termination system part of an external LPS using metallic elements such as rods, mesh conductors or catenary wires intended to intercept lightning flashes. 3.2 average steepness of the front of short stroke current The average rate of change of current in a time period △t = t2 - t1. Note: It is expressed by the difference Δi = i(t 2 ) – i(t 1 ) of the values of the current at the start and at the end of this interval, divided by the time interval Δt = t 2 – t 1 (see Figure A.3). 3.3 bonding bar buses. bar on which metal installations, electric power lines, telecommunication lines and other cables can be bonded to an LPS.
Contents of GB/T 33629-2017
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Symbols and units 5 Abbreviations 6 Lightning environment of wind turbines 7 Lightning exposure assessment 8 Lightning protection of subcomponents 9 Earthing of wind turbines and wind farms 10 Personnel safety 11 Documentation of lightning protection system 12 Inspection of lightning protection system Annex A (informative) The lightning phenomenon in relation to wind turbine generator systems Annex B (informative) Lightning exposure assessment Annex C (Informative) Protection methods for blades Annex D (Informative) Test specification Annex E (Informative) Application of lightning protection zones (LPZ) concept at a wind turbine Annex F (Informative) Selection and installation of a coordinated SPD protection in wind turbines Annex G (Informative) Additional information on bonding and shielding and installation technique Annex H (Informative) Testing methods for system level immunity tests Annex I (Informative) Earth termination system Annex J (Informative) Example of defined measuring points Annex K (Informative) Typical lightning damage questionnaire Annex L (Informative) Monitoring systems Annex M (Informative) Guidelines for small wind turbines - Microgeneration Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 33629-2017, GB 33629-2017, GBT 33629-2017, GB/T33629-2017, GB/T 33629, GB/T33629, GB33629-2017, GB 33629, GB33629, GBT33629-2017, GBT 33629, GBT33629