2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/JB/T 11798-2014
JB/T 11798-2014   Internal Combustion Engines - Heat Exchangers - Wind Tunnel Test Equipments (English Version)
Standard No.: JB/T 11798-2014 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 16500 words Translation Price(USD):410.0 remind me the price change

Email:

Implemented on:2014-10-1 Delivery: via email in 1 business day

→ → →

,,2014-10-1,3E46DFD605CB564A1419403540337
Standard No.: JB/T 11798-2014
English Name: Internal Combustion Engines - Heat Exchangers - Wind Tunnel Test Equipments
Chinese Name: 内燃机 换热器 风洞试验装置
Professional Classification: JB    Professional Standard - Machinery
Source Content Issued by: Ministry of Industry and Information Technology
Issued on: 2014-05-06
Implemented on: 2014-10-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 16500 words
Translation Price(USD): 410.0
Delivery: via email in 1 business day
1 Scope This standard specifies the terms and definitions, symbols and interpretations, overall structure, technical requirements, measurement modules, test control and data acquisition modules, test data processing, validation and evaluation of wind tunnel for heat transfer, and marking, packaging, transport and storage of heat transfer wind tunnel test equipment for heat exchangers of internal combustion engines used in automobiles, tractors, construction machinery and small vessels. This standard is applicable to test equipment for wind tunnel for heat transfer (hereinafter referred to as wind tunnel for heat transfer) for heat exchangers of internal combustion engines (including liquid-gas and gas-gas heat exchange) used in automobiles, tractors, construction machinery, and small vessels to conduct heat transfer performance tests. It may be used as reference for the wind tunnel test equipment for heat exchangers of other purposes. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2624.3 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles GB 11122-2006 Diesel engine oils JJF 1059.1-2012 Evaluation and expression of uncertainty in measurement JJG 667-2010 Liquid positive displacement flowmeter JJG 1038-2008 Goriolis mass flow meters 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 wind tunnel for heat transfer equipment for measuring the heat transfer performance and resistance performance of liquid-gas and gas-gas heat exchange devices 3.2 frontal area the area of the windward side of the core of a heat exchanger with air as the cooling medium 3.3 effectiveness the ratio of the actual heat exchange capacity of the heat exchanger to the maximum possible heat exchange capacity under the same conditions 3.4 hot side the channel through which water flows in the water radiator, the channel through which oil flows in the oil radiator, and the channel through which charge air flows in the air-to-air intercooler 3.5 cool side the channel through which normal pressure air flows in water radiator, oil radiator, and air-to-air intercooler 3.6 conversion trans-heat the trans-heat at set temperature difference (the difference between the designated inlet temperature of high-temperature medium and low-temperature medium) converted from the actual trans-heat under the test condition, and it is also called the standard trans-heat 3.7 pressure drop the static pressure difference formed by the test medium before and after flowing through the heat exchanger under the test condition, and it is also called resistance or working resistance 3.8 standard air the air under the condition with the temperature of 20℃ and the pressure of 101.3 kPa 3.9 accuracy the ability of an instrument to indicate or record a measured truth value, expressed by the difference between the indicated value and the truth value 3.10 precision under the same conditions and repeated measurements of the same physical quantity using the same method, the degree that the obtained indication values are close to the same 3.11 absolute pressure the pressure measured with absolute vacuum as the measurement reference 3.12 mass flowrate the mass of medium flowing through the specified section per unit time 3.13 volume flowrate the volume of medium flowing through a specified section per unit time 3.14 velocity under the test condition, the air velocity at a certain point on the frontal surface of the heat exchanger 3.15 average velocity under the test condition, the weighted average air velocity on the frontal surface of the heat exchanger 3.16 correlation coefficient a measure of the degree of linear correlation between two variables 3.17 specific gas constant proportional constant in the gas equation of state
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Symbols and interpretations 5 Overall structure 5.1 General 5.2 Negative pressure type wind tunnel for heat transfer 5.3 The test section is in the inlet side air chamber 5.4 The test section is in the outlet side air chamber. 5.5 Closed circulating wind tunnel for heat transfer 6 Technical requirements 6.1 Main module of negative pressure type wind tunnel for heat transfer 6.2 Main module of air chamber type wind tunnel for heat transfer 6.3 Closed circulating type wind tunnel for heat transfer 6.4 Hot water module 6.5 Hot oil module 6.6 High temperature and high pressure air module 7 Measurement module 7.1 Test section temperature measurement 7.2 Resistance measurement of test pieces from test section 7.3 Flowrate measurement 8 Test control and data acquisition module 8.1 Measurement control precision 8.2 Test medium 8.3 Test procedure 8.4 Test items 9 Processing of test data 9.1 Calculation of heat exchange capacity 9.2 Calculation of the heat transfer coefficient 9.3 Calculation of the conversion trans-heat 9.4 Calculation of heat balance 10 Validation and evaluation of wind tunnel for heat transfer 10.1 General 10.2 Standard samples 10.3 Verification and evaluation rules 11 Marking, packaging, transport and storage 11.1 Marking 11.2 Packaging 11.3 Transport 11.4 Storage of standard samples 11.5 Others
JB/T 11798-2014 is referred in:
*GB/T 23338-2018 Internal combustion engines—Charge air coolers—Specification
Code of China
Standard
JB/T 11798-2014  Internal Combustion Engines - Heat Exchangers - Wind Tunnel Test Equipments (English Version)
Standard No.JB/T 11798-2014
Statusvalid
LanguageEnglish
File FormatPDF
Word Count16500 words
Price(USD)410.0
Implemented on2014-10-1
Deliveryvia email in 1 business day
Detail of JB/T 11798-2014
Standard No.
JB/T 11798-2014
English Name
Internal Combustion Engines - Heat Exchangers - Wind Tunnel Test Equipments
Chinese Name
内燃机 换热器 风洞试验装置
Chinese Classification
Professional Classification
JB
ICS Classification
Issued by
Ministry of Industry and Information Technology
Issued on
2014-05-06
Implemented on
2014-10-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
16500 words
Price(USD)
410.0
Keywords
JB/T 11798-2014, JB 11798-2014, JBT 11798-2014, JB/T11798-2014, JB/T 11798, JB/T11798, JB11798-2014, JB 11798, JB11798, JBT11798-2014, JBT 11798, JBT11798
Introduction of JB/T 11798-2014
1 Scope This standard specifies the terms and definitions, symbols and interpretations, overall structure, technical requirements, measurement modules, test control and data acquisition modules, test data processing, validation and evaluation of wind tunnel for heat transfer, and marking, packaging, transport and storage of heat transfer wind tunnel test equipment for heat exchangers of internal combustion engines used in automobiles, tractors, construction machinery and small vessels. This standard is applicable to test equipment for wind tunnel for heat transfer (hereinafter referred to as wind tunnel for heat transfer) for heat exchangers of internal combustion engines (including liquid-gas and gas-gas heat exchange) used in automobiles, tractors, construction machinery, and small vessels to conduct heat transfer performance tests. It may be used as reference for the wind tunnel test equipment for heat exchangers of other purposes. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 2624.3 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles GB 11122-2006 Diesel engine oils JJF 1059.1-2012 Evaluation and expression of uncertainty in measurement JJG 667-2010 Liquid positive displacement flowmeter JJG 1038-2008 Goriolis mass flow meters 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 wind tunnel for heat transfer equipment for measuring the heat transfer performance and resistance performance of liquid-gas and gas-gas heat exchange devices 3.2 frontal area the area of the windward side of the core of a heat exchanger with air as the cooling medium 3.3 effectiveness the ratio of the actual heat exchange capacity of the heat exchanger to the maximum possible heat exchange capacity under the same conditions 3.4 hot side the channel through which water flows in the water radiator, the channel through which oil flows in the oil radiator, and the channel through which charge air flows in the air-to-air intercooler 3.5 cool side the channel through which normal pressure air flows in water radiator, oil radiator, and air-to-air intercooler 3.6 conversion trans-heat the trans-heat at set temperature difference (the difference between the designated inlet temperature of high-temperature medium and low-temperature medium) converted from the actual trans-heat under the test condition, and it is also called the standard trans-heat 3.7 pressure drop the static pressure difference formed by the test medium before and after flowing through the heat exchanger under the test condition, and it is also called resistance or working resistance 3.8 standard air the air under the condition with the temperature of 20℃ and the pressure of 101.3 kPa 3.9 accuracy the ability of an instrument to indicate or record a measured truth value, expressed by the difference between the indicated value and the truth value 3.10 precision under the same conditions and repeated measurements of the same physical quantity using the same method, the degree that the obtained indication values are close to the same 3.11 absolute pressure the pressure measured with absolute vacuum as the measurement reference 3.12 mass flowrate the mass of medium flowing through the specified section per unit time 3.13 volume flowrate the volume of medium flowing through a specified section per unit time 3.14 velocity under the test condition, the air velocity at a certain point on the frontal surface of the heat exchanger 3.15 average velocity under the test condition, the weighted average air velocity on the frontal surface of the heat exchanger 3.16 correlation coefficient a measure of the degree of linear correlation between two variables 3.17 specific gas constant proportional constant in the gas equation of state
Contents of JB/T 11798-2014
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Symbols and interpretations 5 Overall structure 5.1 General 5.2 Negative pressure type wind tunnel for heat transfer 5.3 The test section is in the inlet side air chamber 5.4 The test section is in the outlet side air chamber. 5.5 Closed circulating wind tunnel for heat transfer 6 Technical requirements 6.1 Main module of negative pressure type wind tunnel for heat transfer 6.2 Main module of air chamber type wind tunnel for heat transfer 6.3 Closed circulating type wind tunnel for heat transfer 6.4 Hot water module 6.5 Hot oil module 6.6 High temperature and high pressure air module 7 Measurement module 7.1 Test section temperature measurement 7.2 Resistance measurement of test pieces from test section 7.3 Flowrate measurement 8 Test control and data acquisition module 8.1 Measurement control precision 8.2 Test medium 8.3 Test procedure 8.4 Test items 9 Processing of test data 9.1 Calculation of heat exchange capacity 9.2 Calculation of the heat transfer coefficient 9.3 Calculation of the conversion trans-heat 9.4 Calculation of heat balance 10 Validation and evaluation of wind tunnel for heat transfer 10.1 General 10.2 Standard samples 10.3 Verification and evaluation rules 11 Marking, packaging, transport and storage 11.1 Marking 11.2 Packaging 11.3 Transport 11.4 Storage of standard samples 11.5 Others
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
JB/T 11798-2014, JB 11798-2014, JBT 11798-2014, JB/T11798-2014, JB/T 11798, JB/T11798, JB11798-2014, JB 11798, JB11798, JBT11798-2014, JBT 11798, JBT11798