2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/QC/T 418-1999
QC/T 418-1999   Technical requirements o fblade connector for automobile (English Version)
Standard No.: QC/T 418-1999 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 9000 words Translation Price(USD):220.0 remind me the price change

Email:

Implemented on:1991-8-1 Delivery: via email in 1 business day

→ → →

,,1991-8-1,87A4F8CC322C3A8F1513842025324
Standard No.: QC/T 418-1999
English Name: Technical requirements o fblade connector for automobile
Chinese Name: 汽车用片式插接器技术条件
Chinese Classification: T36    Electronic and electrical equipment
Professional Classification: QC    Professional Standard - Automobile
Implemented on: 1991-8-1
Status: valid
Superseded by:QC/T 417.1~417.5-2001
Superseding:ZB T36004-1986
Target Language: English
File Format: PDF
Word Count: 9000 words
Translation Price(USD): 220.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. Technical requirements of blade connector for automobile This standard is applicable to blade connectors (hereinafter referred to as “connectors”) for motor vehicles such as automobiles and motorcycles, as well as tractors. The plug connectors used in the connectors must comply with ZB T36 003-86 Blade connector for automobile. 1 Technical requirements 1.1 The connectors shall be in accordance with those specified in this standard, and shall be manufactured according to the drawings and technical documents approved through established procedure. 1.2 Working environment of connectors 1.2.1 Ambient temperature: -40~75℃ 1.2.2 The average maximum relative humidity of the wettest month is 90%~95% and the average minimum temperature of this month is 25℃. 1.3 Connectors of same types, specifications/dimensions and line number shall be interchangeable. The locating and self-locking mechanism, if any, shall be reliable and flexible. 1.4 The plug sheath and socket sheath of the connector shall have the same surface color and be free form obvious defects such as deformation, scratches and cracks on the surface. 1.5 The blade plug or blade socket shall be placed in an insulating sheath and can withstand a tensile force of 49N without damage. 1.6 The self-locking types of connectors include sheath self-locking and connector self-locking. After the connector is released from the sheath self-locking mechanism, the plug-in and plug-out force shall meet those specified in Table 1.   Table 1 Basic dimension mm Line number Self-locking type Maximize initial plug-in force N The fifth plug-out force N Minimum Maximum 2.8 2 Sheath 35 3 35 3 Plug connector 50 6 50 4 Sheath 65 6 65 6 Plug connector 85 12 85 8 Sheath 85 9 85 9 Plug connector 120 15 120 4.8 2 Sheath 50 4 50 3 Plug connector 70 7 70 4 Sheath 80 7 80 4.8 6 Plug connector 100 14 100 8 Sheath 100 11 100 9 Plug connector 150 18 150 6.3 2 Sheath 60 5 60 3 Plug connector 80 8 80 4 Sheath 90 8 90 6 Plug connector 120 15 120 8 Sheath 120 12 120 9 Plug connector 180 20 180 9.5 2 Sheath 80 20 80 3 Plug connector 120 30 120 1.7 Electrical performance 1.7.1 Insulation dielectric strength The position between the plug connectors in the connector and between the plug connector and the sheath shall be able to withstand a test with a power frequency of 50Hz and actual sinusoidal waveform voltage of 550V for 1min, and shall be free from breakdown damage after such test. During production, such test may be replaced by a test with a voltage of 660V for 1s. 1.7.2 Voltage drop After the connector is plugged well, the voltage drop of each pair of plug connectors shall not exceed 3mV/A. At the end of the humidity resistance, vibration resistance, low temperature resistance and aging resistance tests, the voltage drop of each pair of plug connectors shall not exceed 6mV/A. 1.8 The vibration and impact resistance of the connector shall meet those specified in Table 2.   Table 2 Item vibration frequency Hz Maximum acceleration m/s2 Vibration time/impact counts Vibration 50 98 4h Impact — 147 10,000 times 1.9 Oil resistance After subjected to the oil resistance test, the connector shall be free from abnormal deformation and its basic dimensions shall be in accordance with this standard and the drawings. 1.10 Aging resistance After the connector is subjected to the aging test, the plug and socket sheaths shall be free from brittle rupture and still meet the requirements for electrical performance. 1.11 Plug-in and pull-out durability After the connector has been plugged in and out for 50 times, the voltage drop of each pair of plug connectors shall not exceed 3mV/A. 2 Test method and inspection rules 2.1 The connectors may not be delivered before passing the inspections and shall be accompanied with the supporting documents for conformity of product quality. 2.2 The end-of-manufacturing inspection items of the plug and socket sheaths include: a. Basic dimensions; b. Appearance. 2.3 Type test Products used for type test shall be sampled from those from a same batch and passing the end-of-manufacturing inspection. There shall be at least 15 pairs of samples, divided in 3 groups. 2.3.1 Group I shall be subjected to the durability test. 2.3.2 Group II shall be subjected to the following tests: plug-in and plug-out force test, voltage drop test, interchangeability test, and insulating dielectric strength test. 2.3.3 Group III shall be subjected to the following tests: vibration test, impact test, low temperature test, high temperature test, moisture resistance test, oil resistance test and aging resistance test. 2.4 All the tests shall be carried out under the following conditions: a. the plug connectors used in the connector shall be crimped with wires with corresponding sectional areas, which shall meet the requirements of JB 677-71 Low-voltage wires for automobile and tractor and be put into insulating sheaths. b. The precision grade of the voltmeter shall reach instrument grade, and that of the ammeter shall not be inferior to Grade 1. 2.5 Appearance inspection Visual observation shall be adopted and the appearance shall meet the requirements of 1.4. 2.6 Interchangeability test Dismantle 5 sets of connectors of the same type and dimensions, mix their parts, and assemble them into connectors in arbitrary combination. and the assembled connectors shall meet the requirements of 1.6 and 1.7.2. 2.7 Voltage drop test Plug the connector pairs well, apply a current of 2~10A, and check them according to Figure 1 and Table 3 (the connectors are allowed to be drilled). This test shall be carried out immediately after power-on and the value of voltage drop shall meet the requirements of 1.7.2.
1 Technical requirements 2 Test method and inspection rules 3 Marking, packaging, transportation and storage
Referred in QC/T 418-1999:
*GB/T 34590.9-2017 Road vehicles-Functional safety-Part 9: Automotive Safety Integrity Level (ASI L) -oriented and safety-oriented analyses
*DB44/26-2001 Discharge limits of water pollutants (Guangdong)
*QC/T 533-1999 Test method for bench of automobile drive axle
*TB/T 2879.2-1998 Railway Rolling Stock - Paint and Painting - Part 2: Methods for Testing Paints
*QC/T 546-1999 Automotive Shock Absorber cleanliness limits and determination
*QC/T 29017-1991 Automotive molded plastic parts without individual tolerance limit the size of the deviation
*QC/T 293-1999 Test methods of automotive axle shaft
*TB/T 2879.1-1998 Railway Rolling Stock - Paint and Painting - Part 1: Technical Specification for Supply of Paints
*QC/T 29117.22-1993 Quality inspection of products for motorcycles and mopeds Quality evaluation method of exhaust muffler
*MT/T 199-1996 General specifications for hydraulic drill jumbos for coal mine
*SH/T 0192-1992 Determination of the Aging Characteristics of Lubricating Oil
*GB/T 20314-2017 Thin float glass for liquid crystal display(LCD) applications
*QC/T 260-1998 Center High Mounted Stop Lamp
*DL/T 1672-2016 Aluminium tube bundles used in indirect air cooling system of thermal power plant
QC/T 418-1999 is referred in:
*GB/T 10267.1-1988 Method for analysis of calcium metal. The determination of chlorine content by chloride. Selective electrode
*GB 10267.1-1988 Method for analysis of calcium metal-The determination of chlorine content by chloride-Selective electrode
*GB 50222-1995(2001) Code for Fire Prevention in Design of Interior Decoration of Buildings (2001 edition)
*QB/T 5084-2017 Case and bag. Test method of fasteners
*GB 20799-2016 Fresh and frozen meat transport condition
*GB/T 17425-1998 Purchase and acceptance of couplers and coupler yokes for freight service
*CJJ 44-1991 Code for construction and acceptance of municipal road base works
*CNCA C11-01-2014 China Compulsory Certification Implementation Rules - Motor vehicle [Including CNCA 2017 No.1 Announcement - Modification List]
*GB 2726-2016 Hygienic standard for cooked meat products
*YD/T 1582-2010 800MHz/2GHz cdma2000 digital cellular mobile communication network:signaling link access control (LAC) of air interface specification
*TSG 24-2015 Supervision Regulation on Safety Technology for Hyperbaric Oxygen Chambers
Code of China
Standard
QC/T 418-1999  Technical requirements o fblade connector for automobile (English Version)
Standard No.QC/T 418-1999
Statusvalid
LanguageEnglish
File FormatPDF
Word Count9000 words
Price(USD)220.0
Implemented on1991-8-1
Deliveryvia email in 1 business day
Detail of QC/T 418-1999
Standard No.
QC/T 418-1999
English Name
Technical requirements o fblade connector for automobile
Chinese Name
汽车用片式插接器技术条件
Chinese Classification
T36
Professional Classification
QC
ICS Classification
Issued by
Issued on
Implemented on
1991-8-1
Status
valid
Superseded by
QC/T 417.1~417.5-2001
Superseded on
Abolished on
Superseding
ZB T36004-1986
Language
English
File Format
PDF
Word Count
9000 words
Price(USD)
220.0
Keywords
QC/T 418-1999, QC 418-1999, QCT 418-1999, QC/T418-1999, QC/T 418, QC/T418, QC418-1999, QC 418, QC418, QCT418-1999, QCT 418, QCT418
Introduction of QC/T 418-1999
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. Technical requirements of blade connector for automobile This standard is applicable to blade connectors (hereinafter referred to as “connectors”) for motor vehicles such as automobiles and motorcycles, as well as tractors. The plug connectors used in the connectors must comply with ZB T36 003-86 Blade connector for automobile. 1 Technical requirements 1.1 The connectors shall be in accordance with those specified in this standard, and shall be manufactured according to the drawings and technical documents approved through established procedure. 1.2 Working environment of connectors 1.2.1 Ambient temperature: -40~75℃ 1.2.2 The average maximum relative humidity of the wettest month is 90%~95% and the average minimum temperature of this month is 25℃. 1.3 Connectors of same types, specifications/dimensions and line number shall be interchangeable. The locating and self-locking mechanism, if any, shall be reliable and flexible. 1.4 The plug sheath and socket sheath of the connector shall have the same surface color and be free form obvious defects such as deformation, scratches and cracks on the surface. 1.5 The blade plug or blade socket shall be placed in an insulating sheath and can withstand a tensile force of 49N without damage. 1.6 The self-locking types of connectors include sheath self-locking and connector self-locking. After the connector is released from the sheath self-locking mechanism, the plug-in and plug-out force shall meet those specified in Table 1.   Table 1 Basic dimension mm Line number Self-locking type Maximize initial plug-in force N The fifth plug-out force N Minimum Maximum 2.8 2 Sheath 35 3 35 3 Plug connector 50 6 50 4 Sheath 65 6 65 6 Plug connector 85 12 85 8 Sheath 85 9 85 9 Plug connector 120 15 120 4.8 2 Sheath 50 4 50 3 Plug connector 70 7 70 4 Sheath 80 7 80 4.8 6 Plug connector 100 14 100 8 Sheath 100 11 100 9 Plug connector 150 18 150 6.3 2 Sheath 60 5 60 3 Plug connector 80 8 80 4 Sheath 90 8 90 6 Plug connector 120 15 120 8 Sheath 120 12 120 9 Plug connector 180 20 180 9.5 2 Sheath 80 20 80 3 Plug connector 120 30 120 1.7 Electrical performance 1.7.1 Insulation dielectric strength The position between the plug connectors in the connector and between the plug connector and the sheath shall be able to withstand a test with a power frequency of 50Hz and actual sinusoidal waveform voltage of 550V for 1min, and shall be free from breakdown damage after such test. During production, such test may be replaced by a test with a voltage of 660V for 1s. 1.7.2 Voltage drop After the connector is plugged well, the voltage drop of each pair of plug connectors shall not exceed 3mV/A. At the end of the humidity resistance, vibration resistance, low temperature resistance and aging resistance tests, the voltage drop of each pair of plug connectors shall not exceed 6mV/A. 1.8 The vibration and impact resistance of the connector shall meet those specified in Table 2.   Table 2 Item vibration frequency Hz Maximum acceleration m/s2 Vibration time/impact counts Vibration 50 98 4h Impact — 147 10,000 times 1.9 Oil resistance After subjected to the oil resistance test, the connector shall be free from abnormal deformation and its basic dimensions shall be in accordance with this standard and the drawings. 1.10 Aging resistance After the connector is subjected to the aging test, the plug and socket sheaths shall be free from brittle rupture and still meet the requirements for electrical performance. 1.11 Plug-in and pull-out durability After the connector has been plugged in and out for 50 times, the voltage drop of each pair of plug connectors shall not exceed 3mV/A. 2 Test method and inspection rules 2.1 The connectors may not be delivered before passing the inspections and shall be accompanied with the supporting documents for conformity of product quality. 2.2 The end-of-manufacturing inspection items of the plug and socket sheaths include: a. Basic dimensions; b. Appearance. 2.3 Type test Products used for type test shall be sampled from those from a same batch and passing the end-of-manufacturing inspection. There shall be at least 15 pairs of samples, divided in 3 groups. 2.3.1 Group I shall be subjected to the durability test. 2.3.2 Group II shall be subjected to the following tests: plug-in and plug-out force test, voltage drop test, interchangeability test, and insulating dielectric strength test. 2.3.3 Group III shall be subjected to the following tests: vibration test, impact test, low temperature test, high temperature test, moisture resistance test, oil resistance test and aging resistance test. 2.4 All the tests shall be carried out under the following conditions: a. the plug connectors used in the connector shall be crimped with wires with corresponding sectional areas, which shall meet the requirements of JB 677-71 Low-voltage wires for automobile and tractor and be put into insulating sheaths. b. The precision grade of the voltmeter shall reach instrument grade, and that of the ammeter shall not be inferior to Grade 1. 2.5 Appearance inspection Visual observation shall be adopted and the appearance shall meet the requirements of 1.4. 2.6 Interchangeability test Dismantle 5 sets of connectors of the same type and dimensions, mix their parts, and assemble them into connectors in arbitrary combination. and the assembled connectors shall meet the requirements of 1.6 and 1.7.2. 2.7 Voltage drop test Plug the connector pairs well, apply a current of 2~10A, and check them according to Figure 1 and Table 3 (the connectors are allowed to be drilled). This test shall be carried out immediately after power-on and the value of voltage drop shall meet the requirements of 1.7.2.
Contents of QC/T 418-1999
1 Technical requirements 2 Test method and inspection rules 3 Marking, packaging, transportation and storage
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
QC/T 418-1999, QC 418-1999, QCT 418-1999, QC/T418-1999, QC/T 418, QC/T418, QC418-1999, QC 418, QC418, QCT418-1999, QCT 418, QCT418