2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/SH/T 0505-1992
SH/T 0505-1992   Test Method for Shear Stability of Polymer Containing Fluids (Ultrasonic Shear Method) (English Version)
Standard No.: SH/T 0505-1992 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 2000 words Translation Price(USD):40.0 remind me the price change

Email:

Implemented on:1992-5-20 Delivery: via email in 1 business day

→ → →

,2018-6-1,1992-5-20,141137295442277A18144E97FFFE1
Standard No.: SH/T 0505-1992
English Name: Test Method for Shear Stability of Polymer Containing Fluids (Ultrasonic Shear Method)
Chinese Name: 含聚合物油剪切安定性测定法(超声波剪切法)
Professional Classification: SH    Professional Standard - Petrochemical
Source Content Issued by: Sinopec
Issued on: 1992-5-20
Implemented on: 1992-5-20
Status: superseded
Superseded by:NB/SH/T 0505-2017 Standard test method for determination of shear stalbility of polymer- -containing oils by ultrasonic shear method
Superseded on:2018-6-1
Target Language: English
File Format: PDF
Word Count: 2000 words
Translation Price(USD): 40.0
Delivery: via email in 1 business day
1 Subject Content and Application Scope This standard specifies the test method for shear stability of polymer containing liquid by adopting the ultrasonic shear method. This standard is applicable to the polymer containing hydraulic fluids and internal combustion engine oil. 2 Normative References GB/T 265 Petroleum Products-Determination of Kinematic Viscosity and Calculation of Dynamic Viscosity GB 1992 Solvent Naphthas 3 Method Summary Adequate amount of polymer containing test specimen shall be placed on the contacting rod of amplitude transformer for ultrasonic shear treatment in fixed time by one time or several times, and the variance in viscosity shall be determined according to GB/T 265, at last, the decrease rate of the sample shall be calculated. The shear stability shall be assessed according to viscosity decrease rate of the fluid caused by ultrasonic shear action in the amplitude transformer (namely, ultrasonic oscillator). 4 Instruments and Materials 4.1 Instruments 4.1.1 Ultrasonic shear tester: output end of the amplitude transformer for ultrasonic shear test is arranged as a cylindrical rod with a diameter of 20mm, its end surface shall not be punched with center hole and chamfered for angles, the surface roughness shall not be less than , the resonant frequency shall be 20kHz±1kHz, and the output power shall be larger than or equal to 250W. Note: the ultrasonic shear device of type CSJ-III shall be produced by Kaifeng Second Instrument Factory. 4.1.2 Stopwatch: the scale interval shall be 0.2s. 4.1.3 Measuring cylinder: 50mL. 4.1.4 Beaker: 100mL. 4.1.5 Thermometer: bar thermometer of 0 ~ 100℃. 4.1.6 Viscosity tester: the viscometer and thermostatic waterbath in accordance with the requirements of GB/T 265. 4.2 Materials Reference fluid: CSJ-Standard No.2 oil, the viscosity decrease rate shall be 16%±1% under standard shear test conditions (namely, the test specimen amount shall be 30mL, the cooling water temperature shall be 38℃ and the shearing duration shall be 10min). Note: the CSJ-Standard No.2 oil shall be provided by the Research Institute of Petroleum Processing (RIPP). 5 Reagents Petroleum ether: analytically pure, 60~90℃ (or the solvent naphthas in accordance with the requirements of No.90 in GB 1992).
1 Subject Content and Application Scope 2 Normative References 3 Method Summary 4 Instruments and Materials 5 Reagents 6 Preparation Works 7 Test Procedures 8 Calculation 9 Precision 10 Report Additional Explanation
Referred in SH/T 0505-1992:
*GB/T 265-1988 Petroleum Products - Determination of Kinematic Viscosity and Calculation of Dynamic Viscosity
*GB 1992-1985 Freight containers; Terminology
SH/T 0505-1992 is referred in:
* GB 11122-2006 Diesel engine oils
* GB 11121-2006 Gasoline engine oils
*GJB 1177A-2013 Specification for No.15 aviation hydraulic fluid
*GB/T 21449-2008 Water glycol fire-resistant hydraulic fluids
Code of China
Standard
SH/T 0505-1992  Test Method for Shear Stability of Polymer Containing Fluids (Ultrasonic Shear Method) (English Version)
Standard No.SH/T 0505-1992
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count2000 words
Price(USD)40.0
Implemented on1992-5-20
Deliveryvia email in 1 business day
Detail of SH/T 0505-1992
Standard No.
SH/T 0505-1992
English Name
Test Method for Shear Stability of Polymer Containing Fluids (Ultrasonic Shear Method)
Chinese Name
含聚合物油剪切安定性测定法(超声波剪切法)
Chinese Classification
Professional Classification
SH
ICS Classification
Issued by
Sinopec
Issued on
1992-5-20
Implemented on
1992-5-20
Status
superseded
Superseded by
NB/SH/T 0505-2017 Standard test method for determination of shear stalbility of polymer- -containing oils by ultrasonic shear method
Superseded on
2018-6-1
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
2000 words
Price(USD)
40.0
Keywords
SH/T 0505-1992, SH 0505-1992, SHT 0505-1992, SH/T0505-1992, SH/T 0505, SH/T0505, SH0505-1992, SH 0505, SH0505, SHT0505-1992, SHT 0505, SHT0505
Introduction of SH/T 0505-1992
1 Subject Content and Application Scope This standard specifies the test method for shear stability of polymer containing liquid by adopting the ultrasonic shear method. This standard is applicable to the polymer containing hydraulic fluids and internal combustion engine oil. 2 Normative References GB/T 265 Petroleum Products-Determination of Kinematic Viscosity and Calculation of Dynamic Viscosity GB 1992 Solvent Naphthas 3 Method Summary Adequate amount of polymer containing test specimen shall be placed on the contacting rod of amplitude transformer for ultrasonic shear treatment in fixed time by one time or several times, and the variance in viscosity shall be determined according to GB/T 265, at last, the decrease rate of the sample shall be calculated. The shear stability shall be assessed according to viscosity decrease rate of the fluid caused by ultrasonic shear action in the amplitude transformer (namely, ultrasonic oscillator). 4 Instruments and Materials 4.1 Instruments 4.1.1 Ultrasonic shear tester: output end of the amplitude transformer for ultrasonic shear test is arranged as a cylindrical rod with a diameter of 20mm, its end surface shall not be punched with center hole and chamfered for angles, the surface roughness shall not be less than , the resonant frequency shall be 20kHz±1kHz, and the output power shall be larger than or equal to 250W. Note: the ultrasonic shear device of type CSJ-III shall be produced by Kaifeng Second Instrument Factory. 4.1.2 Stopwatch: the scale interval shall be 0.2s. 4.1.3 Measuring cylinder: 50mL. 4.1.4 Beaker: 100mL. 4.1.5 Thermometer: bar thermometer of 0 ~ 100℃. 4.1.6 Viscosity tester: the viscometer and thermostatic waterbath in accordance with the requirements of GB/T 265. 4.2 Materials Reference fluid: CSJ-Standard No.2 oil, the viscosity decrease rate shall be 16%±1% under standard shear test conditions (namely, the test specimen amount shall be 30mL, the cooling water temperature shall be 38℃ and the shearing duration shall be 10min). Note: the CSJ-Standard No.2 oil shall be provided by the Research Institute of Petroleum Processing (RIPP). 5 Reagents Petroleum ether: analytically pure, 60~90℃ (or the solvent naphthas in accordance with the requirements of No.90 in GB 1992).
Contents of SH/T 0505-1992
1 Subject Content and Application Scope 2 Normative References 3 Method Summary 4 Instruments and Materials 5 Reagents 6 Preparation Works 7 Test Procedures 8 Calculation 9 Precision 10 Report Additional Explanation
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
SH/T 0505-1992, SH 0505-1992, SHT 0505-1992, SH/T0505-1992, SH/T 0505, SH/T0505, SH0505-1992, SH 0505, SH0505, SHT0505-1992, SHT 0505, SHT0505