YY/T 0804-2010   Transfer sets for pharmaceutical preparations―Requirements and test methods (English Version)
Standard No.: YY/T 0804-2010 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 12500 words Translation Price(USD):375.0 remind me the price change

Email:

Implemented on:2012-6-1 Delivery: via email in 1 business day

→ → →

,,2012-6-1,E3768F8949C37F731663738846753
Standard No.: YY/T 0804-2010
English Name: Transfer sets for pharmaceutical preparations―Requirements and test methods
Chinese Name: 药液转移器 要求和试验方法
Chinese Classification: C31    General and microsurgical devices
Professional Classification: YY    Professional Standard - Pharmaceutics
ICS Classification: 11.040.20 11.040.20    Transfusion, infusion and injection equipment 11.040.20
Source Content Issued by: SDA
Issued on: 2010-12-27
Implemented on: 2012-6-1
Status: valid
Target Language: English
File Format: PDF
Word Count: 12500 words
Translation Price(USD): 375.0
Delivery: via email in 1 business day
YY/T 0804-2010 Transfer sets for pharmaceutical preparations - Requirements and test methods 1 Scope This standard is applicable to sterilized single use transfer sets that are used for pharmaceutical preparations. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 1962.1 Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirement (GB/T 1962.1-2001, ISO 594-1:1986, IDT) GB/T 1962.2 Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings (GB/T 1962.2-2001, ISO 594-2:1998, IDT) GB 8368 Infusion sets for single use - Gravity feed (GB 8368-2005, ISO 8536-4: 2004, MOD) GB 15811-2001 Sterile hypodermic needles for single use (eqv ISO 7864:1993) YY/T 0466.1 Medical devices- Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements (YY 0466.1-2009, ISO 15223-1:2007, IDT) ISO 8362 Injection container and its accessories ISO 8536-2 Infusion equipment for medical use - Part 2: Closures for infusion bottles ISO 15747:2003 Plastics containers for intravenous injection ISO 15759:2005 Medical infusion equipment - Plastics caps with inserted elastomeric liner for containers manufactured by the blow-fill-seal (BFS) process 3 Design and designation 3.1 Design of transfer set without housing The designs of the individual components are given in the drawings (Figures 1 to 4). The drawings serve as an illustration of possible designs of transfer sets. Other designs are acceptable. a) Transfer set with one channel b) Transfer set with one channel, combined with a Luer taper Figure 1 Transfer set with one channel a) Transfer set with an air inlet/air outlet b) Alternative transfer set with an air inlet/air outlet c) Transfer set with an air inlet, combined with a Luer taper Figure 2 Transfer set with an air inlet a) Transfer set with two channels b) Alternative transfer set with two channels Figure 3 Transfer set with two channels Key for Figures 1 to 3 1——piercing device; 2——channel; 3——channel with air filter for ventilation, optionally lockable; 4——protective cap; 5——connection of piercing devices by hub, grip plate or tube; 6——internal Luer taper. 3.2 Design of a transfer set with housing The design of a transfer set with housing is given in Figure 4. The drawings serve as an illustration of possible types of transfer sets. Other designs are acceptable.
Foreword i Introduction ii 1 Scope 2 Normative references 3 Design and designation 4 Material 5 Physical requirements 6 Chemical requirements 7 Biological requirements 8 Test method 9 Testing of chemical requirements 10 Testing of biological requirements 11 Packaging 12 Storage 13 Labelling Annex A (Normative) Testing of fragmentation of transfer sets with plastic piercing devices Annex B (Normative) Testing of fragmentation of transfer sets with metal piercing devices Annex NA (Normative) Technical differences between this standard and ISO 22413:2007 and their justifications Bibliography
Referred in YY/T 0804-2010:
*GB/T 1962.1-2015 Conical fittings with a 6%(Luer) taper for syringes,needles and certain other medical equipment—Part 1: General requirement
*GB/T 1962.2-2001 Conical fittings with a 6%(Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings
*GB 8368-2018 Infusion sets for single use—Gravity feed
*GB 15811-2001/XG1 Sterile hypodermic needles for single use, includes Amendment 1
*YY/T 0466.1-2023 Medical devices―Symbols to be used with information to be supplied by the manufacturer―Part 1:General requirements
Code of China
Standard
YY/T 0804-2010  Transfer sets for pharmaceutical preparations―Requirements and test methods (English Version)
Standard No.YY/T 0804-2010
Statusvalid
LanguageEnglish
File FormatPDF
Word Count12500 words
Price(USD)375.0
Implemented on2012-6-1
Deliveryvia email in 1 business day
Detail of YY/T 0804-2010
Standard No.
YY/T 0804-2010
English Name
Transfer sets for pharmaceutical preparations―Requirements and test methods
Chinese Name
药液转移器 要求和试验方法
Chinese Classification
C31
Professional Classification
YY
ICS Classification
Issued by
SDA
Issued on
2010-12-27
Implemented on
2012-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
12500 words
Price(USD)
375.0
Keywords
YY/T 0804-2010, YY 0804-2010, YYT 0804-2010, YY/T0804-2010, YY/T 0804, YY/T0804, YY0804-2010, YY 0804, YY0804, YYT0804-2010, YYT 0804, YYT0804
Introduction of YY/T 0804-2010
YY/T 0804-2010 Transfer sets for pharmaceutical preparations - Requirements and test methods 1 Scope This standard is applicable to sterilized single use transfer sets that are used for pharmaceutical preparations. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 1962.1 Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirement (GB/T 1962.1-2001, ISO 594-1:1986, IDT) GB/T 1962.2 Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 2: Lock fittings (GB/T 1962.2-2001, ISO 594-2:1998, IDT) GB 8368 Infusion sets for single use - Gravity feed (GB 8368-2005, ISO 8536-4: 2004, MOD) GB 15811-2001 Sterile hypodermic needles for single use (eqv ISO 7864:1993) YY/T 0466.1 Medical devices- Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements (YY 0466.1-2009, ISO 15223-1:2007, IDT) ISO 8362 Injection container and its accessories ISO 8536-2 Infusion equipment for medical use - Part 2: Closures for infusion bottles ISO 15747:2003 Plastics containers for intravenous injection ISO 15759:2005 Medical infusion equipment - Plastics caps with inserted elastomeric liner for containers manufactured by the blow-fill-seal (BFS) process 3 Design and designation 3.1 Design of transfer set without housing The designs of the individual components are given in the drawings (Figures 1 to 4). The drawings serve as an illustration of possible designs of transfer sets. Other designs are acceptable. a) Transfer set with one channel b) Transfer set with one channel, combined with a Luer taper Figure 1 Transfer set with one channel a) Transfer set with an air inlet/air outlet b) Alternative transfer set with an air inlet/air outlet c) Transfer set with an air inlet, combined with a Luer taper Figure 2 Transfer set with an air inlet a) Transfer set with two channels b) Alternative transfer set with two channels Figure 3 Transfer set with two channels Key for Figures 1 to 3 1——piercing device; 2——channel; 3——channel with air filter for ventilation, optionally lockable; 4——protective cap; 5——connection of piercing devices by hub, grip plate or tube; 6——internal Luer taper. 3.2 Design of a transfer set with housing The design of a transfer set with housing is given in Figure 4. The drawings serve as an illustration of possible types of transfer sets. Other designs are acceptable.
Contents of YY/T 0804-2010
Foreword i Introduction ii 1 Scope 2 Normative references 3 Design and designation 4 Material 5 Physical requirements 6 Chemical requirements 7 Biological requirements 8 Test method 9 Testing of chemical requirements 10 Testing of biological requirements 11 Packaging 12 Storage 13 Labelling Annex A (Normative) Testing of fragmentation of transfer sets with plastic piercing devices Annex B (Normative) Testing of fragmentation of transfer sets with metal piercing devices Annex NA (Normative) Technical differences between this standard and ISO 22413:2007 and their justifications Bibliography
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
YY/T 0804-2010, YY 0804-2010, YYT 0804-2010, YY/T0804-2010, YY/T 0804, YY/T0804, YY0804-2010, YY 0804, YY0804, YYT0804-2010, YYT 0804, YYT0804