Position: Chinese Standard in English/GB 15930-2024
GB 15930-2024   Fire dampers for building venting and smoke-venting system (English Version)
Standard No.: GB 15930-2024 Status:to be valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 17000 words Price(USD):510.0 remind me the price change

Email:

Implemented on:2026-3-1 Delivery: via email in 1 business day
,,
Standard No.: GB 15930-2024
English Name: Fire dampers for building venting and smoke-venting system
Chinese Name: 建筑通风和排烟系统用防火阀门
Professional Classification: GB    National Standard
Issued by: SAMR; SAC
Issued on: 2024-11-28
Implemented on: 2026-3-1
Status: to be valid
Superseding:GB 15930-2007 Fire dampers for building venting and smoke-venting system
Language: English
File Format: PDF
Word Count: 17000 words
Price(USD): 510.0
Delivery: via email in 1 business day
GB 15930-2024 Fire dampers for building venting and smoke-venting system 1 Scope This document defines the terms and definitions of fire dampers, combination fire and smoke dampers, smoke dampers, constant closed ventilation valves and automatic smoke exhaust windows, specifies classification, materials, fittings, appearance and tolerances, technical requirements, inspection rules, marking, packaging, transportation and storage, and describes the corresponding test methods. This document is applicable to the design, manufacture and inspection of fire dampers installed in the ventilation and air conditioning systems of industrial and civil buildings and underground buildings or kitchen fume exhaust systems, combination fire and smoke dampers and smoke dampers installed in mechanical smoke exhaust systems, and constant closed ventilation valves installed in mechanical pressurized ventilation systems, and automatic smoke exhaust windows for natural smoke exhaust systems. Note: As for fire dampers used on other occasions, this document shall be implemented with reference. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191 Packaging - Pictorial marking for handling of goods GB/T 1804 General tolerances - Tolerances for linear and angular dimensions without individual tolerance indications GB/T 2624 (All parts) Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full GB 4717 Fire alarm control units GB/T 5907 (All parts) Fire protection vocabulary GB/T 6682 Water for analytical laboratory use - Specification and test methods GB/T 9969 General principles for preparation of instructions for use of industrial products GB/T 9978.1 Fire-resistance tests - Elements of building construction - Part 1: General requirements GB/T 13306 Plates GB/T 13384 General specifications for packing of mechanical and electrical product XF 863 General requirements for fusible element for fire protection 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 5907 (all parts), GB/T 9978.1 and the following apply. 3.1 fire damper smoke prevention equipment that can meet the specified fire resistance grade requirements and play a role in isolating smoke and fire within a certain period of time, which is installed on the air supply and return ducts of ventilation and air conditioning systems or installed at the branch pipe connecting the fume exhaust ducts and the vertical exhaust ducts in kitchens of public buildings, and keeps open in daily time but gets closed when the smoke and gas temperature in the pipe reaches the rated operating temperature Note: Fire damper is generally composed of such components as valve body, blade, open and close device and thermal release mechanism. 3.2 combination fire and smoke damper smoke exhaust equipment with smoke isolation and fire resistance, which is installed on the pipe of the mechanical smoke exhaust system, keeps open in daily time but get closed when the smoke temperature in the smoke exhaust duct reaches 280°C, can meet the requirements of smoke leakage and fire resistance integrity within a certain period of time Note: Combination fire and smoke damper is generally composed of such components as valve body, blade, open and close device and thermal release mechanism. 3.3 smoke damper smoke exhaust equipment installed at the end of each branch pipe (smoke suction port) of the mechanical smoke exhaust system, which keeps closed and meets the air leakage requirements in daily time but manually and electrically gets open in case of fire or in need for smoke exhaust, and thus plays the role of smoke exhaust Note: Smoke damper is generally composed of such components as valve body, blade, as well as open and close device. Smoke damper equipped with decorative materials or accessories is usually called smoke exhaust port. 3.4 constant closed ventilation valve ventilation equipment installed in the front room of the stairs, on the side of the smoke prevention system duct or at the end of the air duct, which keeps closed and meets the requirements of air leakage in daily time but manually and electrically gets open and plays a role of pressurization and ventilation in case of fire or in need for an auxiliary pressurization system to ventilate Note: Constant closed ventilation valve is generally composed of valve body, blade, open and close device. Constant closed ventilation valve equipped with decorative materials or accessories is usually called constant closed vent. 3.5 automatic smoke exhaust window smoke exhaust equipment installed on the top or exterior wall of the smoke exhaust area of a building, which can open the window sash manually, by thermal release mechanism or under the control of an automatic fire alarm system, so that smoke and hot air is exhausted out of the room in a natural ventilation manner Note: Automatic smoke exhaust window is generally composed of window body, window sash, open and close device, thermal release mechanism, power source. 3.6 open and close device device installed on a fire damper for building venting and smoke-venting system, and operated by manual control, electric control or thermal release mechanism to realize the open and close function of the fire damper Note: According to the functional requirements, the open and close operation of the open and close device may be a combination of one or several control modes. 3.7 thermal release mechanism temperature control device for evaluating the air flow temperature parameter at a preset position, which can start and control the close and open of the dampers, automatic smoke exhaust window, etc. when it reaches the preset value Note: The temperature sensing element is fusible sheet, memory alloy and electronic sensor. 4 Classification and code, nominal dimension and model 4.1 Classification and code 4.1.1 Classification by purpose Fire dampers are classified by uses into five categories: fire dampers, combination fire and smoke dampers, smoke dampers, constant closed ventilation valves, and automatic smoke exhaust windows. The product names and codes shall be as specified in Table 1. Table 1 Product names and codes of fire dampers
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and code, nominal dimension and model 4.1 Classification and code 4.2 Nominal dimension 4.3 Models
Referred in GB 15930-2024:
*GB/T 191-2008 Packaging - Pictorial Marking for Handling of Goods
*GB/T 1804-2000 General Tolerances - Tolerances for Linear and Angular Dimensions without Individual Tolerance Indications
*GB/T 2624-1993 Measurement of fluid flow by means of orifice plates, nozzles and Venturi tubes inserted in circular cross-section conduits running full
*GB 4717-2024 Fire alarm control units
*GBT5907-
*GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods
*GB/T 9969-2008 General Principles for Preparation of Instructions for Use of Industrial Products
*GB/T 9978.1-2008 Fire-Resistance Tests-Elements of Building Construction Part1: General Requirements
*GB/T 13306-2011 Plate
*GB/T 13384-2008 General specifications for packing of mechanical and electrical product
*XF 863-2010 General requirements for fusible element for fire protection
Code of China
Standard
GB 15930-2024  Fire dampers for building venting and smoke-venting system (English Version)
Standard No.GB 15930-2024
Statusto be valid
LanguageEnglish
File FormatPDF
Word Count17000 words
Price(USD)510.0
Implemented on2026-3-1
Deliveryvia email in 1 business day
Detail of GB 15930-2024
Standard No.
GB 15930-2024
English Name
Fire dampers for building venting and smoke-venting system
Chinese Name
建筑通风和排烟系统用防火阀门
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2024-11-28
Implemented on
2026-3-1
Status
to be valid
Superseded by
Superseded on
Abolished on
Superseding
GB 15930-2007 Fire dampers for building venting and smoke-venting system
Language
English
File Format
PDF
Word Count
17000 words
Price(USD)
510.0
Keywords
GB 15930-2024, GB/T 15930-2024, GBT 15930-2024, GB15930-2024, GB 15930, GB15930, GB/T15930-2024, GB/T 15930, GB/T15930, GBT15930-2024, GBT 15930, GBT15930
Introduction of GB 15930-2024
GB 15930-2024 Fire dampers for building venting and smoke-venting system 1 Scope This document defines the terms and definitions of fire dampers, combination fire and smoke dampers, smoke dampers, constant closed ventilation valves and automatic smoke exhaust windows, specifies classification, materials, fittings, appearance and tolerances, technical requirements, inspection rules, marking, packaging, transportation and storage, and describes the corresponding test methods. This document is applicable to the design, manufacture and inspection of fire dampers installed in the ventilation and air conditioning systems of industrial and civil buildings and underground buildings or kitchen fume exhaust systems, combination fire and smoke dampers and smoke dampers installed in mechanical smoke exhaust systems, and constant closed ventilation valves installed in mechanical pressurized ventilation systems, and automatic smoke exhaust windows for natural smoke exhaust systems. Note: As for fire dampers used on other occasions, this document shall be implemented with reference. 2 Normative references The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191 Packaging - Pictorial marking for handling of goods GB/T 1804 General tolerances - Tolerances for linear and angular dimensions without individual tolerance indications GB/T 2624 (All parts) Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full GB 4717 Fire alarm control units GB/T 5907 (All parts) Fire protection vocabulary GB/T 6682 Water for analytical laboratory use - Specification and test methods GB/T 9969 General principles for preparation of instructions for use of industrial products GB/T 9978.1 Fire-resistance tests - Elements of building construction - Part 1: General requirements GB/T 13306 Plates GB/T 13384 General specifications for packing of mechanical and electrical product XF 863 General requirements for fusible element for fire protection 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 5907 (all parts), GB/T 9978.1 and the following apply. 3.1 fire damper smoke prevention equipment that can meet the specified fire resistance grade requirements and play a role in isolating smoke and fire within a certain period of time, which is installed on the air supply and return ducts of ventilation and air conditioning systems or installed at the branch pipe connecting the fume exhaust ducts and the vertical exhaust ducts in kitchens of public buildings, and keeps open in daily time but gets closed when the smoke and gas temperature in the pipe reaches the rated operating temperature Note: Fire damper is generally composed of such components as valve body, blade, open and close device and thermal release mechanism. 3.2 combination fire and smoke damper smoke exhaust equipment with smoke isolation and fire resistance, which is installed on the pipe of the mechanical smoke exhaust system, keeps open in daily time but get closed when the smoke temperature in the smoke exhaust duct reaches 280°C, can meet the requirements of smoke leakage and fire resistance integrity within a certain period of time Note: Combination fire and smoke damper is generally composed of such components as valve body, blade, open and close device and thermal release mechanism. 3.3 smoke damper smoke exhaust equipment installed at the end of each branch pipe (smoke suction port) of the mechanical smoke exhaust system, which keeps closed and meets the air leakage requirements in daily time but manually and electrically gets open in case of fire or in need for smoke exhaust, and thus plays the role of smoke exhaust Note: Smoke damper is generally composed of such components as valve body, blade, as well as open and close device. Smoke damper equipped with decorative materials or accessories is usually called smoke exhaust port. 3.4 constant closed ventilation valve ventilation equipment installed in the front room of the stairs, on the side of the smoke prevention system duct or at the end of the air duct, which keeps closed and meets the requirements of air leakage in daily time but manually and electrically gets open and plays a role of pressurization and ventilation in case of fire or in need for an auxiliary pressurization system to ventilate Note: Constant closed ventilation valve is generally composed of valve body, blade, open and close device. Constant closed ventilation valve equipped with decorative materials or accessories is usually called constant closed vent. 3.5 automatic smoke exhaust window smoke exhaust equipment installed on the top or exterior wall of the smoke exhaust area of a building, which can open the window sash manually, by thermal release mechanism or under the control of an automatic fire alarm system, so that smoke and hot air is exhausted out of the room in a natural ventilation manner Note: Automatic smoke exhaust window is generally composed of window body, window sash, open and close device, thermal release mechanism, power source. 3.6 open and close device device installed on a fire damper for building venting and smoke-venting system, and operated by manual control, electric control or thermal release mechanism to realize the open and close function of the fire damper Note: According to the functional requirements, the open and close operation of the open and close device may be a combination of one or several control modes. 3.7 thermal release mechanism temperature control device for evaluating the air flow temperature parameter at a preset position, which can start and control the close and open of the dampers, automatic smoke exhaust window, etc. when it reaches the preset value Note: The temperature sensing element is fusible sheet, memory alloy and electronic sensor. 4 Classification and code, nominal dimension and model 4.1 Classification and code 4.1.1 Classification by purpose Fire dampers are classified by uses into five categories: fire dampers, combination fire and smoke dampers, smoke dampers, constant closed ventilation valves, and automatic smoke exhaust windows. The product names and codes shall be as specified in Table 1. Table 1 Product names and codes of fire dampers
Contents of GB 15930-2024
Foreword i 1 Scope 2 Normative references 3 Terms and definitions 4 Classification and code, nominal dimension and model 4.1 Classification and code 4.2 Nominal dimension 4.3 Models