2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 50118-2010
GB 50118-2010   Code for sound insulation design of civil buildings (English Version)
Standard No.: GB 50118-2010 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 11000 words Translation Price(USD):270.0 remind me the price change

Email:

Implemented on:2011-6-1 Delivery: via email in 1 business day

→ → →

,,2011-6-1,14113818189330E004173B14508FA
Standard No.: GB 50118-2010
English Name: Code for sound insulation design of civil buildings
Chinese Name: 民用建筑隔声设计规范
Chinese Classification: P31    Architectural physics
Professional Classification: GB    National Standard
Source Content Issued by: MOHURD
Issued on: 2010-8-18
Implemented on: 2011-6-1
Status: valid
Superseding:GBJ 118-1988 Acoustics - Specifications for the Design of Sound Insulation in Civilian Structure
Target Language: English
File Format: PDF
Word Count: 11000 words
Translation Price(USD): 270.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This code is formulated with a view to reducing noise influence to civil buildings and ensuring favorable sound environment in civil buildings. 1.0.2 This code is applicable to the sound insulation, sound absorption and noise reduction design for main houses in 6 categories of constructed, renovated and extended buildings such as dwelling, school, hospital, hotel, office-building and commercial building in towns and cities all over the country. As for rooms in other categories of buildings, corresponding provisions of this code can be adopted according to their functions. 1.0.3 A-weighted sound pressure level shall be adopted as the rating quantity of limits for indoor noise levels in this code. The limits for indoor noise levels in this code shall be the standard values under the closed window condition at daytime and nighttime. As for the rooms with open windows in hospital, the standard values of limits for indoor noise levels under the open window condition should be the same as those under the closed window condition. Corresponding time of daytime and nighttime respectively is: daytime, 6:00~22:00; nighttime, 22:00~6:00; or as the requirements of local People's Government. The measurement of indoor noise level shall be carried out according to those specified in Appendix A of this code. 1.0.4 As for the design of sound insulation and noise reduction of civil buildings, not only the requirements stipulated in this code, but also those in the current relevant standards of the nation shall be complied with. 2 Terminologies and Symbols 2.1 Terminologies 2.1.1 A-weighted sound pressure level Sound pressure level measured by A-weighted network. 2.1.2 Equivalent [continuous A-weighted] sound pressure level Within the stipulated time limit, A [-weighted] sound pressure of a certain continuous steady-state sound has the same mean square A [-weighted] sound pressure as the time-varying noise, so the sound level of this continuous steady-state sound is the equivalent sound level of this time-varying noise, and the unit is decibel (dB). 2.1.3 Air-borne sound The sound featured by sound source spreading toward surrounding areas through air. 2.1.4 Impact sound Noise caused by impacting on building structures. 2.1.5 Single-number quantity Single sound insulation parameter determined in comprehensive consideration of the sound insulation performance of objects at 1/3 octave within the range of 100Hz~3,150Hz center frequency (or 1/1 octave within the range of 135Hz~2,000Hz center frequency), according to the methods specified in the national standard "Rating Standard of Sound Insulation in Buildings" (GB/T 50121-2005). 2.1.6 Weighted sound reduction index Single-number quantity representing the air-borne sound insulation performance of building members. Weighted sound reduction index should be measured in the laboratory. 2.1.7 Weighted standardized level difference Single-number quantity of air-borne sound insulation performance between two rooms obtained by using the reverberation time of reception room as the correction parameter. 2.1.8 Weighted normalized impact sound pressure level Single-number quantity of impact sound insulation performance of floorslabs or floorslab structures obtained by using the sound absorption index of reception room as the correction parameter. 2.11.9 Weighted standardized impact sound pressure level Single-number quantity of impact sound insulation performance of floorslabs or floorslab structures obtained by using the reverberation time of reception room as the correction parameter. 2.1.10 Spectrum adaptation term Spectrum adaptation term is the corrected value added to the single-number quantity of air-borne sound insulation due to different sound insulation spectrums and different noise spectrums in sound source space. When the noise in sound source space is in the pink noise frequency characteristics or traffic noise frequency characteristics, the calculated spectrum adaptation term is pink noise spectrum adaptation term or traffic noise spectrum adaptation term respectively. 2.1.11 Noise reduction coefficient Single value of material sound absorption characteristics obtained by calculating the measured values of random incident absorption coefficient at 1/3 octave within the range of 200Hz~2,500Hz center frequency. 2.2 Symbols C - pink noise spectrum adaptation term; Ctr - traffic noise spectrum adaptation term; DnT,w - weighted standardized level difference; LAeq,T - equivalent [continuous A-weighted] sound pressure level; Ln,w - weighted normalized impact sound pressure level; L′nT,w - weighted standardized impact sound pressure level; NRC - noise reduction coefficient; Rw - weighted sound reduction index.
1 General Provisions 2 Terminologies and Symbols 2.1 Terminologies 2.2 Symbols 3 Planning of Noise Reduction 4 Dwelling 4.1 Limits for Indoor Noise Levels 4.2 Criteria for Sound Insulation 4.3 Design of Sound Insulation and Noise Reduction 5 School 5.1 Limits for Indoor Noise Levels 5.2 Criteria for Sound Insulation 5.3 Design of Sound Insulation and Noise Reduction 6 Hospital 6.1 Limits for Indoor Noise Levels 6.2 Criteria for Sound Insulation 6.3 Design of Sound Insulation and Noise Reduction 7 Hotel 7.1 Limits for Indoor Noise Levels 7.2 Criteria for Sound Insulation 7.3 Design of Sound Insulation and Noise Reduction 8 Office-building 8.1 Limits for Indoor Noise Levels 8.2 Criteria for Sound Insulation 8.3 Design of Sound Insulation and Noise Reduction 9 Commercial Building 9.1 Limits for Indoor Noise Levels 9.2 Indoor Sound Absorption 9.3 Criteria for Sound Insulation 9.4 Design of Sound Insulation and Noise Reduction Appendix A Method for Measuring Indoor Noise Levels Explanation of Wording in This Code List of Quoted Standards
Referred in GB 50118-2010:
* GB/T 50121-2005 Rating standard of sound insulation in buildings
* GB 3096-2008 Environmental Quality Standard for Noise
* GB/T 3241-2010 Electroacoustics - Octave-band and fractional-octave-band filters
* GB/T 3785.1-2010 Electroacoustics—Sound level meters—Part 1:Specifications
* GB/T 17181-1999 Integral average sound level meter
* GB/T 15173-2010 Electroacoustics—Sound calibrators
GB 50118-2010 is referred in:
* GB/T 50378-2014 Assessment Standard for Green Building
* DGJ 08-56-2012 Technical Code for Building Curtain Wall
* GB/T 50378-2014 Assessment Standard for Green Building
* GB/T 50378-2014 Assessment Standard for Green Building
* GB/T 50378-2014 Assessment Standard for Green Building
* DGJ 08-56-2012 Technical Code for Building Curtain Wall
* GB/T 50378-2014 Assessment Standard for Green Building
* GB/T 50378-2014 Assessment Standard for Green Building
* GB/T 50908-2013 Evaluation Standard for Green Office Building
* GB/T 50908-2013 Evaluation Standard for Green Office Building
* JGJ 62-2014 Code for Design of Hotel Building
* GB 51039-2014 Code for design of general hospital
* JGJ/T 304-2013 Code for Construction Quality Acceptance of Housing Interior Decoration
* CECS 158-2015 Technical specification for membrane structures
* GB/T 51165-2016 Assessment Standard For Green Building
*GB 50352-2019 Unified standard for design of civil building
*GB 50015-2019 Standard for design of building water supply and drainage
*GB/T 50378-2019 Assessment standard for green building
*GB 50210-2018 Standard for construction quality acceptance of building decoration
*T/CEA 0054-2024 Evaluation requirements of green product —Traction lift
*GB 50400-2016 Technical code for rainwater management and utilization of building and sub- district
*GB/T 17216-2025 Hygienic requirement for peacetime utilization of civil air defence works
*GB/T 9981-2025 Hygienic specification for rural residential buildings
Code of China
Standard
GB 50118-2010  Code for sound insulation design of civil buildings (English Version)
Standard No.GB 50118-2010
Statusvalid
LanguageEnglish
File FormatPDF
Word Count11000 words
Price(USD)270.0
Implemented on2011-6-1
Deliveryvia email in 1 business day
Detail of GB 50118-2010
Standard No.
GB 50118-2010
English Name
Code for sound insulation design of civil buildings
Chinese Name
民用建筑隔声设计规范
Chinese Classification
P31
Professional Classification
GB
ICS Classification
Issued by
MOHURD
Issued on
2010-8-18
Implemented on
2011-6-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GBJ 118-1988 Acoustics - Specifications for the Design of Sound Insulation in Civilian Structure
Language
English
File Format
PDF
Word Count
11000 words
Price(USD)
270.0
Keywords
GB 50118-2010, GB/T 50118-2010, GBT 50118-2010, GB50118-2010, GB 50118, GB50118, GB/T50118-2010, GB/T 50118, GB/T50118, GBT50118-2010, GBT 50118, GBT50118
Introduction of GB 50118-2010
1 General Provisions 1.0.1 This code is formulated with a view to reducing noise influence to civil buildings and ensuring favorable sound environment in civil buildings. 1.0.2 This code is applicable to the sound insulation, sound absorption and noise reduction design for main houses in 6 categories of constructed, renovated and extended buildings such as dwelling, school, hospital, hotel, office-building and commercial building in towns and cities all over the country. As for rooms in other categories of buildings, corresponding provisions of this code can be adopted according to their functions. 1.0.3 A-weighted sound pressure level shall be adopted as the rating quantity of limits for indoor noise levels in this code. The limits for indoor noise levels in this code shall be the standard values under the closed window condition at daytime and nighttime. As for the rooms with open windows in hospital, the standard values of limits for indoor noise levels under the open window condition should be the same as those under the closed window condition. Corresponding time of daytime and nighttime respectively is: daytime, 6:00~22:00; nighttime, 22:00~6:00; or as the requirements of local People's Government. The measurement of indoor noise level shall be carried out according to those specified in Appendix A of this code. 1.0.4 As for the design of sound insulation and noise reduction of civil buildings, not only the requirements stipulated in this code, but also those in the current relevant standards of the nation shall be complied with. 2 Terminologies and Symbols 2.1 Terminologies 2.1.1 A-weighted sound pressure level Sound pressure level measured by A-weighted network. 2.1.2 Equivalent [continuous A-weighted] sound pressure level Within the stipulated time limit, A [-weighted] sound pressure of a certain continuous steady-state sound has the same mean square A [-weighted] sound pressure as the time-varying noise, so the sound level of this continuous steady-state sound is the equivalent sound level of this time-varying noise, and the unit is decibel (dB). 2.1.3 Air-borne sound The sound featured by sound source spreading toward surrounding areas through air. 2.1.4 Impact sound Noise caused by impacting on building structures. 2.1.5 Single-number quantity Single sound insulation parameter determined in comprehensive consideration of the sound insulation performance of objects at 1/3 octave within the range of 100Hz~3,150Hz center frequency (or 1/1 octave within the range of 135Hz~2,000Hz center frequency), according to the methods specified in the national standard "Rating Standard of Sound Insulation in Buildings" (GB/T 50121-2005). 2.1.6 Weighted sound reduction index Single-number quantity representing the air-borne sound insulation performance of building members. Weighted sound reduction index should be measured in the laboratory. 2.1.7 Weighted standardized level difference Single-number quantity of air-borne sound insulation performance between two rooms obtained by using the reverberation time of reception room as the correction parameter. 2.1.8 Weighted normalized impact sound pressure level Single-number quantity of impact sound insulation performance of floorslabs or floorslab structures obtained by using the sound absorption index of reception room as the correction parameter. 2.11.9 Weighted standardized impact sound pressure level Single-number quantity of impact sound insulation performance of floorslabs or floorslab structures obtained by using the reverberation time of reception room as the correction parameter. 2.1.10 Spectrum adaptation term Spectrum adaptation term is the corrected value added to the single-number quantity of air-borne sound insulation due to different sound insulation spectrums and different noise spectrums in sound source space. When the noise in sound source space is in the pink noise frequency characteristics or traffic noise frequency characteristics, the calculated spectrum adaptation term is pink noise spectrum adaptation term or traffic noise spectrum adaptation term respectively. 2.1.11 Noise reduction coefficient Single value of material sound absorption characteristics obtained by calculating the measured values of random incident absorption coefficient at 1/3 octave within the range of 200Hz~2,500Hz center frequency. 2.2 Symbols C - pink noise spectrum adaptation term; Ctr - traffic noise spectrum adaptation term; DnT,w - weighted standardized level difference; LAeq,T - equivalent [continuous A-weighted] sound pressure level; Ln,w - weighted normalized impact sound pressure level; L′nT,w - weighted standardized impact sound pressure level; NRC - noise reduction coefficient; Rw - weighted sound reduction index.
Contents of GB 50118-2010
1 General Provisions 2 Terminologies and Symbols 2.1 Terminologies 2.2 Symbols 3 Planning of Noise Reduction 4 Dwelling 4.1 Limits for Indoor Noise Levels 4.2 Criteria for Sound Insulation 4.3 Design of Sound Insulation and Noise Reduction 5 School 5.1 Limits for Indoor Noise Levels 5.2 Criteria for Sound Insulation 5.3 Design of Sound Insulation and Noise Reduction 6 Hospital 6.1 Limits for Indoor Noise Levels 6.2 Criteria for Sound Insulation 6.3 Design of Sound Insulation and Noise Reduction 7 Hotel 7.1 Limits for Indoor Noise Levels 7.2 Criteria for Sound Insulation 7.3 Design of Sound Insulation and Noise Reduction 8 Office-building 8.1 Limits for Indoor Noise Levels 8.2 Criteria for Sound Insulation 8.3 Design of Sound Insulation and Noise Reduction 9 Commercial Building 9.1 Limits for Indoor Noise Levels 9.2 Indoor Sound Absorption 9.3 Criteria for Sound Insulation 9.4 Design of Sound Insulation and Noise Reduction Appendix A Method for Measuring Indoor Noise Levels Explanation of Wording in This Code List of Quoted Standards
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 50118-2010, GB/T 50118-2010, GBT 50118-2010, GB50118-2010, GB 50118, GB50118, GB/T50118-2010, GB/T 50118, GB/T50118, GBT50118-2010, GBT 50118, GBT50118