2025-6-18 18.97.9.172
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 9330.2-2008
GB/T 9330.2-2008   Plastic Insulated Control Cables - Part 2: Polyvinyl Chloride Insulated and Sheathed Control Cables (English Version)
Standard No.: GB/T 9330.2-2008 Status:superseded remind me the status change

Email:

Language:English File Format:PDF
Word Count: 6000 words Price(USD):150.0 remind me the price change

Email:

Implemented on:2009-4-1 Delivery: via email in 1 business day
,,
Standard No.: GB/T 9330.2-2008
English Name: Plastic Insulated Control Cables - Part 2: Polyvinyl Chloride Insulated and Sheathed Control Cables
Chinese Name: 塑料绝缘控制电缆 第2部分:聚氯乙烯绝缘和护套控制电缆
Chinese Classification: K13    Cable and its accessory
Professional Classification: GB    National Standard
ICS Classification: 29.060.20 29.060.20    Cables 29.060.20
Issued by: AQSIQ; SAC
Issued on: 30-Jun-08
Implemented on: 2009-4-1
Status: superseded
Superseded by:GB/T 9330-2020 Plastic insulated control cables
Superseded on:2020-10-1
Abolished on:2020-10-01
Superseding:GB 9330.2-1988 Plastic insulated control cables-Polyvinyl chloride insulated and sheathed control cables
Language: English
File Format: PDF
Word Count: 6000 words
Price(USD): 150.0
Delivery: via email in 1 business day
1 Scope This Part of GB/T 9330 specifies the technical requirements of polyvinyl chloride insulated and sheathed control cable with rated voltage≤450/750V. This Part is applicable to the polyvinyl chloride insulated and sheathed control cables with rated voltage≤450/750V applied in the control and monitoring loops as well as in the protective lines. All the cables shall be in accordance with the corresponding requirements specified in GB/T 9330.1-2008 and all models of cables shall be respectively in accordance with the special requirement specified in this Part. 2 Normative References The following standards contain provisions which, through reference in this Part of GB/T 9330, constitute provisions of this standard. For dated reference, subsequent amendments to or revisions of, any of these publications (excluding correction content) do not apply. However, the parties whose enter into agreement according to this Standard are encouraged to research whether the latest editions of these documents are applied or not. For undated references, the latest edition of the normative document is applicable to this standard. " Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables -Part 11: Methods for General Application - Measurement of Thickness and Overall Dimensions - Tests for Determining the Mechanical Properties" (GB/T 2951.11-2008) (IEC 60811-1-1: 2001, IDT). "Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables-Part 12: Methods for General Application-Thermal Ageing Methods" (GB/T 2951.12-2008) (IEC 60811-1-2: 1985, IDT) "Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables—Part 14:Methods for General Application—Test at Low Temperature (GB/T 2951.14-2008) (IEC 60811-1-4:1985, IDT) "Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables-Part 31: Methods Specific to PVC Compounds-Pressure Test at High Temperature-Test for Resistance to Cracking" (GB/T 2951.31-2008) (IEC 60811-3-1:1985, IDT) "Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables-Part 31: Methods Specific to PVC Compounds-Loss of Mass Test—Thermal Stability Test" (GB/T 2951.32-2008) (IEC 60811-3-2: 1985, IDT) "Protective coverings for electric cables; Part 1:General" (GB/T 2952.1-1989 ) " Test Methods for Electrical Properties of Electric Cables and Wires—Part 4:Test of DC Resistance of Conductors" (GB/T 3048.4-2007) "Test Methods for Electrical Properties of Electric Cables and Wires-Part 5:Test of Insulation Resistance" (GB/T 3048.5-2007) "Test Methods for Electrical Properties of Electric Cables and Wires—Part 8:AC voltage test" (GB/T 3048.8-2007) "Plastic Insulated Control Cables - Part 1: General Requirements" (GB/T 9330.1 - 2008) "Flame Retardant and Fire Resistant Wires and Cables General" (GB/T 19666-2005) 3 Operating Characteristics 3.1 Rated voltage Rated voltage U0/U is 450/750 V. 3.2 Operating temperature of cable Long-term allowable operating temperature of cable conductors is 70℃. 3.3 Laying temperature of cable Laying temperature of cable shall not be less than 0℃. 3.4 Allowable bending diameter of cable ——For the cable without armor layer, it shall not be less than 6 times of the outside diameter of cable; ——For the cable with armor or in copper tape shield structure, it shall not be less than 12 times of the outside diameter of cable; ——For the cable without armor layer, it shall not be less than 6 times of the outside diameter of cable;
Foreword I 1 Scope 2 Normative References 3 Operating Characteristics 4 Models 5 Specifications 6 Technical Requirements 7 Finished Cable 8 Inspection Rules
Referred in GB/T 9330.2-2008:
*GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 11:Methods for general application - Measurement of thickness and overall dimensions
*GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 12: Methods for general application - Thermal ageing methods
*GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 14: Methods for general application - Test at low temperature
*GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 31: Methods specific to PVC compounds - Pressure test at high temperature - Test for
*GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 32: Methods specific to PVC compounds - Loss of mass test - Thermal stability test
*GB/T 2952.1-1989 Protective coverings for electric cables; Part 1:General
*GB/T 3048.4-2007 Test methods for electrical properties of electric cables and wires—Part 4:Test of DC resistance of conductors
*GB/T 3048.5-2007 Test methods for electrical properties of electric cables and wires—Part 5:Test of insulation resistance
*GB/T 3048.8-2007 Test methods for electrical properties of electric cables and wires—Part 8:AC voltage test
*GB/T 9330.1-2008 Plastic Insulated Control Cables - Part 1: General Requirements
*GB/T 19666-2005 Flame retardant and fire resistant wires and cables
Code of China
Standard
GB/T 9330.2-2008  Plastic Insulated Control Cables - Part 2: Polyvinyl Chloride Insulated and Sheathed Control Cables (English Version)
Standard No.GB/T 9330.2-2008
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count6000 words
Price(USD)150.0
Implemented on2009-4-1
Deliveryvia email in 1 business day
Detail of GB/T 9330.2-2008
Standard No.
GB/T 9330.2-2008
English Name
Plastic Insulated Control Cables - Part 2: Polyvinyl Chloride Insulated and Sheathed Control Cables
Chinese Name
塑料绝缘控制电缆 第2部分:聚氯乙烯绝缘和护套控制电缆
Chinese Classification
K13
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
30-Jun-08
Implemented on
2009-4-1
Status
superseded
Superseded by
GB/T 9330-2020 Plastic insulated control cables
Superseded on
2020-10-1
Abolished on
2020-10-01
Superseding
GB 9330.2-1988 Plastic insulated control cables-Polyvinyl chloride insulated and sheathed control cables
Language
English
File Format
PDF
Word Count
6000 words
Price(USD)
150.0
Keywords
GB/T 9330.2-2008, GB 9330.2-2008, GBT 9330.2-2008, GB/T9330.2-2008, GB/T 9330.2, GB/T9330.2, GB9330.2-2008, GB 9330.2, GB9330.2, GBT9330.2-2008, GBT 9330.2, GBT9330.2
Introduction of GB/T 9330.2-2008
1 Scope This Part of GB/T 9330 specifies the technical requirements of polyvinyl chloride insulated and sheathed control cable with rated voltage≤450/750V. This Part is applicable to the polyvinyl chloride insulated and sheathed control cables with rated voltage≤450/750V applied in the control and monitoring loops as well as in the protective lines. All the cables shall be in accordance with the corresponding requirements specified in GB/T 9330.1-2008 and all models of cables shall be respectively in accordance with the special requirement specified in this Part. 2 Normative References The following standards contain provisions which, through reference in this Part of GB/T 9330, constitute provisions of this standard. For dated reference, subsequent amendments to or revisions of, any of these publications (excluding correction content) do not apply. However, the parties whose enter into agreement according to this Standard are encouraged to research whether the latest editions of these documents are applied or not. For undated references, the latest edition of the normative document is applicable to this standard. " Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables -Part 11: Methods for General Application - Measurement of Thickness and Overall Dimensions - Tests for Determining the Mechanical Properties" (GB/T 2951.11-2008) (IEC 60811-1-1: 2001, IDT). "Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables-Part 12: Methods for General Application-Thermal Ageing Methods" (GB/T 2951.12-2008) (IEC 60811-1-2: 1985, IDT) "Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables—Part 14:Methods for General Application—Test at Low Temperature (GB/T 2951.14-2008) (IEC 60811-1-4:1985, IDT) "Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables-Part 31: Methods Specific to PVC Compounds-Pressure Test at High Temperature-Test for Resistance to Cracking" (GB/T 2951.31-2008) (IEC 60811-3-1:1985, IDT) "Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables-Part 31: Methods Specific to PVC Compounds-Loss of Mass Test—Thermal Stability Test" (GB/T 2951.32-2008) (IEC 60811-3-2: 1985, IDT) "Protective coverings for electric cables; Part 1:General" (GB/T 2952.1-1989 ) " Test Methods for Electrical Properties of Electric Cables and Wires—Part 4:Test of DC Resistance of Conductors" (GB/T 3048.4-2007) "Test Methods for Electrical Properties of Electric Cables and Wires-Part 5:Test of Insulation Resistance" (GB/T 3048.5-2007) "Test Methods for Electrical Properties of Electric Cables and Wires—Part 8:AC voltage test" (GB/T 3048.8-2007) "Plastic Insulated Control Cables - Part 1: General Requirements" (GB/T 9330.1 - 2008) "Flame Retardant and Fire Resistant Wires and Cables General" (GB/T 19666-2005) 3 Operating Characteristics 3.1 Rated voltage Rated voltage U0/U is 450/750 V. 3.2 Operating temperature of cable Long-term allowable operating temperature of cable conductors is 70℃. 3.3 Laying temperature of cable Laying temperature of cable shall not be less than 0℃. 3.4 Allowable bending diameter of cable ——For the cable without armor layer, it shall not be less than 6 times of the outside diameter of cable; ——For the cable with armor or in copper tape shield structure, it shall not be less than 12 times of the outside diameter of cable; ——For the cable without armor layer, it shall not be less than 6 times of the outside diameter of cable;
Contents of GB/T 9330.2-2008
Foreword I 1 Scope 2 Normative References 3 Operating Characteristics 4 Models 5 Specifications 6 Technical Requirements 7 Finished Cable 8 Inspection Rules
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: TransForyou Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 9330.2-2008, GB 9330.2-2008, GBT 9330.2-2008, GB/T9330.2-2008, GB/T 9330.2, GB/T9330.2, GB9330.2-2008, GB 9330.2, GB9330.2, GBT9330.2-2008, GBT 9330.2, GBT9330.2