Position: Chinese Standard in English/GB 50174-2017
GB 50174-2017   Code for design of electronic information systern room (English Version)
Standard No.: GB 50174-2017 Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 30000 words Price(USD):550.0 remind me the price change

Email:

Implemented on:2018-1-1 Delivery: via email in 1 business day
,,
Standard No.: GB 50174-2017
English Name: Code for design of electronic information systern room
Chinese Name: 数据中心设计规范
Professional Classification: GB    National Standard
Issued by: MOHURD
Issued on: 2017-05-04
Implemented on: 2018-1-1
Status: valid
Superseding:GB 50174-2008 Code for Design of Electronic Information System Room
Language: English
File Format: PDF
Word Count: 30000 words
Price(USD): 550.0
Delivery: via email in 1 business day
1 General Provisions 1.0.1 This code is formulated with view to standardizing the design of data center, ensuring the safe, stable and reliable operation of electronic information system, and achieving technical advancement, economic feasibility, safety and usability as well as energy conservation and environment protection. 1.0.2 This code is applicable to the design of newly-built, renovated and extended data centers. 1.0.3 The design of data center shall comply with the principle of keeping short-term construction scale and long-term development plan consistent. 1.0.4 Besides the requirements stipulated in this code, the design of data center shall also comply with those stipulated in the current relevant standards of the nation. 2 Terms and Symbols 2.1 Terms 2.1.1 data center the building site for providing operating environment for the electronic information equipment placed centrally, which can be one or several building(s) or a part of one building, including computer room, auxiliary area, support area and administrative area, etc. 2.1.2 computer room the building space mainly used for the installation and operation of data processing equipment and including functional area such as server room, network equipment room, storage room 2.1.3 auxiliary area the place for the installation, commissioning, maintenance, operation monitoring and management of electronic information equipment and software, including entrance room, test equipment room, enterprise command center, fire protection and security control room, unpacking area, spare parts storeroom, printing room, maintenance room, etc. 2.1.4 support area the area providing power support and safety guarantee for computer room and auxiliary area, including power transformation and distribution room, diesel generator room, battery room, air-conditioner room, power station room, uninterruptible power system room, fire protection device room, etc. 2.1.5 administrative area the place for daily administration and customer's management on managed devices, including office, hall, duty room, washroom, dressing room and user's work room 2.1.6 business recovery data center the place for taking over the operation of production system, making data processing and supporting the operation of critical business functions in case of disaster, including restricted area, regular area and dedicated area 2.1.7 restricted area the place restricting the accessing of different categories of personnel according to safety needs, including computer room, auxiliary area and support area, etc. 2.1.8 regular area the place for disaster recovery, routine training and working 2.1.9 dedicated area the place for using and placing equipment during disaster recovery period 2.1.10 infrastructure in this code, it refers to the facilities providing operation guarantee for electronic information equipment in data center 2.1.11 electronic information equipment the equipment performing processing such as acquisition, processing, calculation, storage, transfer and retrieval of electronic information, including server, exchanger, storage equipment, etc. 2.1.12 redundancy some or all parts of system are repeatedly configured so that, in case of systemic fault, they can interfere in and undertake the operation of faulty part to extend the mean time interval between failures of system 2.1.13 N+X redundancy besides meeting basic requirement by system, X components, X units, X modules or X paths are added. The fault or maintenance of any of the X components, units, modules or paths will not lead to system outage (X=1~N) 2.1.14 fault tolerant if there are two or more systems, at least one system operates normally at the same time. The infrastructure configured according to fault tolerant system shall meet the basic requirement for normal operation of electronic information equipment after subjecting to one serious sudden equipment fault or man-made misoperation 2.1.15 electromagnetic interference (EMI) degradation of device, equipment or system performance induced by electromagnetic disturbance 2.1.16 electromagnetic shielding a shielding to reduce the penetration of alternating electromagnetic field into a designated area through conducting material. 2.1.17 electromagnetic shielding enclosure the building space body used exclusively for attenuating and isolating the energy from external or internal electric and magnetic fields 2.1.18 cut-off waveguide vent the device combining cut-off waveguide and vent, which allows for ventilation and can attenuate electromagnetic wave within a certain frequency range 2.1.19 modular electromagnetic shielding enclosure electromagnetic shielding enclosure with dismountable structure, which is built with module board of pre-shaped shielding enclosure, structural member, shielding component and the like via assembly on construction site according to design requirements 2.1.20 welded electromagnetic shielding enclosure electromagnetic shielding enclosure with fixed structure, whose main structure is constructed by site welding 2.1.21 remote power panel (RPP) equipment for providing distribution arrangement for cabinets arrayed in a rows or divided according to functional area 2.1.22 horizontal distribution area cabinet horizontal distribution area equipment for providing network service for cabinets arrayed in a rows or divided according to functional area 2.1.23 intelligent cabling management system a set of complete soft/hardware integration system, which realizes the intelligent management for tracing, recording and reporting cabling system and network equipment connection state by monitoring the connection attribute of electronic distribution equipment port in real time 2.1.24 static state air conditioning system of computer room is under normal operating state; indoor temperature and dew point temperature meet the operating requirement of electronic information equipment, but electronic information equipment does not operate 2.1.25 dynamic state air conditioning system and electronic information equipment of computer room are under normal operating state and there are relevant personnel in the room 2.1.26 stop condition air conditioning system of computer room and auxiliary area are under normal operating state; indoor temperature and relative humidity meet stop requirements of electronic information equipment 2.1.27 electrostatic leakage the phenomenon that the electrostatic charge on electrified body disappeared partially or completely through the interior or surface of electrified body
1 General Provisions 2 Terms and Symbols 2.1 Terms 2.2 Symbols 3 Rating Classification and Required Features 3.1 Rating Classification 3.2 Required Features 4 Site Selection and Equipment Layout 4.1 Site Selection 4.2 Composition 4.3 Equipment Layout 5 Environmental Requirement 5.1 Temperature, Dew Point Temperature and Airborne Particle Concentration 5.2 Noise, Electromagnetic Interference, Vibration and Static Electricity 6 Building and Structure 6.1 General Requirements 6.2 People Flow, Goods Flow, Entrances and Exits 6.3 Retaining Structure Thermal Design and Energy Saving Measure 6.4 Interior Decoration 7 Air Conditioning 7.1 General Requirements 7.2 Thermal Load Calculation 7.3 Airflow Management 7.4 System Design 7.5 Equipment Selection 8 Electrical Systems 8.1 Power Supply and Distribution 8.2 Lighting 8.3 Electrostatic Discharge Protection 8.4 Lightning Protection and Earthing 9 Electromagnetic Shielding 9.1 General Requirements 9.2 Shielding Structure 9.3 Shielding Objects 10 Network and Cabling System 10.1 Network System 10.2 Cabling System 11 Intelligent System 11.1 General Requirements 11.2 Environment and Equipment Monitoring System 11.3 Security System 11.4 Enterprise Command Center 12 Water Supply and Drainage 12.1 General Requirements 12.2 Piping Layout 13 Fire Protection and Safety 13.1 General Requirements 13.2 Fire Prevention and Evacuation 13.3 Fire Protection Facilities 13.4 Safety Measures Annex A Technical Requirements for Data Center Ratings Explanation of Wording in This Code List of Quoted Standards
Referred in GB 50174-2017:
*GB 50016-2014(2018)-Provisions Provisions of Code for Fire Protection Design of Buildings
*GB 50023-2009 Standard for seismic appraisal of buildings
*GB 50034-2013 Standard for lighting design of buildings
*GB 50052-2009 Code for Design Electric Power Supply Systems
*GB 50057-2010 Design Code for Protection of Structures against Lightning
*GB 50084-2017-EP Explanation on provisions for code of design for sprinkler systems
*GB 50116-2013 Code for design of automatic fire alarm system
*GB 50140-2005 Code for Design of Extinguisher Distribution in Buildings
*GB 50156-2021 Technical standard of fuelling station
*GB 50160-2008 Fire Prevention Code of Petrochemical Enterprise Design (Edition 2018)
*GB 50189-2015 Design Standard for Energy Efficiency of Public Buildings
*GB 50222-2017 Code for Fire Prevention in Design of Interior Decoration of Buildings
*GB 50311-2016 Code for engineering design of generic cabling system
*GB 50314-2015 Standard for design of intelligent building
*GB 50343-2012 Technical code for protection of building electronic information system against lightning
*GB 50348-2018 Technisal code for engineering of security and protection system
*GB 50367-2013 Code for Design of Strengthen Concrete Structure
*GB 50370-2005 Code for design of gas fire extinguishing systems
*GB 50464-2008 Code for technical of video display system engineering
*GB 50611-2010 Code for design of protection of electrostatic discharge in electronic engineering
*GB 50736-2012 Design Code for Heating Ventilation and Air Conditioning of Civil Buildings
*GB 50898-2013 Code of Water Mist Fire Protection Systems
*GB/T 7106-2019 Test methods of air permeability,watertightness,wind load resistance performance for building external windows and doors
*GB/T 14549-1993 Quality of Electric Energy Supply - Harmonics in Public Supply Network
*GB 17625.1-2012 Electromagnetic compatibility—Limits—Limits for harmonic current emissions(equipment input current ≤16 A per phase)
*GB/T 18883-2022 Standards for indoor air quality
*JGJ 116-2009 Technical specification for seismic strengthening of buildings
*JGJ 145-2013 Technical specification for post-installed fastenings in concrete structures
GB 50174-2017 is referred in:
*GB 50037-2013 Code for design of ground surface and floor of building
*GB/T 21431-2008 Technical specifications for inspection of lightning protection system in building
Code of China
Standard
GB 50174-2017  Code for design of electronic information systern room (English Version)
Standard No.GB 50174-2017
Statusvalid
LanguageEnglish
File FormatPDF
Word Count30000 words
Price(USD)550.0
Implemented on2018-1-1
Deliveryvia email in 1 business day
Detail of GB 50174-2017
Standard No.
GB 50174-2017
English Name
Code for design of electronic information systern room
Chinese Name
数据中心设计规范
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
MOHURD
Issued on
2017-05-04
Implemented on
2018-1-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 50174-2008 Code for Design of Electronic Information System Room
Language
English
File Format
PDF
Word Count
30000 words
Price(USD)
550.0
Keywords
GB 50174-2017, GB/T 50174-2017, GBT 50174-2017, GB50174-2017, GB 50174, GB50174, GB/T50174-2017, GB/T 50174, GB/T50174, GBT50174-2017, GBT 50174, GBT50174
Introduction of GB 50174-2017
1 General Provisions 1.0.1 This code is formulated with view to standardizing the design of data center, ensuring the safe, stable and reliable operation of electronic information system, and achieving technical advancement, economic feasibility, safety and usability as well as energy conservation and environment protection. 1.0.2 This code is applicable to the design of newly-built, renovated and extended data centers. 1.0.3 The design of data center shall comply with the principle of keeping short-term construction scale and long-term development plan consistent. 1.0.4 Besides the requirements stipulated in this code, the design of data center shall also comply with those stipulated in the current relevant standards of the nation. 2 Terms and Symbols 2.1 Terms 2.1.1 data center the building site for providing operating environment for the electronic information equipment placed centrally, which can be one or several building(s) or a part of one building, including computer room, auxiliary area, support area and administrative area, etc. 2.1.2 computer room the building space mainly used for the installation and operation of data processing equipment and including functional area such as server room, network equipment room, storage room 2.1.3 auxiliary area the place for the installation, commissioning, maintenance, operation monitoring and management of electronic information equipment and software, including entrance room, test equipment room, enterprise command center, fire protection and security control room, unpacking area, spare parts storeroom, printing room, maintenance room, etc. 2.1.4 support area the area providing power support and safety guarantee for computer room and auxiliary area, including power transformation and distribution room, diesel generator room, battery room, air-conditioner room, power station room, uninterruptible power system room, fire protection device room, etc. 2.1.5 administrative area the place for daily administration and customer's management on managed devices, including office, hall, duty room, washroom, dressing room and user's work room 2.1.6 business recovery data center the place for taking over the operation of production system, making data processing and supporting the operation of critical business functions in case of disaster, including restricted area, regular area and dedicated area 2.1.7 restricted area the place restricting the accessing of different categories of personnel according to safety needs, including computer room, auxiliary area and support area, etc. 2.1.8 regular area the place for disaster recovery, routine training and working 2.1.9 dedicated area the place for using and placing equipment during disaster recovery period 2.1.10 infrastructure in this code, it refers to the facilities providing operation guarantee for electronic information equipment in data center 2.1.11 electronic information equipment the equipment performing processing such as acquisition, processing, calculation, storage, transfer and retrieval of electronic information, including server, exchanger, storage equipment, etc. 2.1.12 redundancy some or all parts of system are repeatedly configured so that, in case of systemic fault, they can interfere in and undertake the operation of faulty part to extend the mean time interval between failures of system 2.1.13 N+X redundancy besides meeting basic requirement by system, X components, X units, X modules or X paths are added. The fault or maintenance of any of the X components, units, modules or paths will not lead to system outage (X=1~N) 2.1.14 fault tolerant if there are two or more systems, at least one system operates normally at the same time. The infrastructure configured according to fault tolerant system shall meet the basic requirement for normal operation of electronic information equipment after subjecting to one serious sudden equipment fault or man-made misoperation 2.1.15 electromagnetic interference (EMI) degradation of device, equipment or system performance induced by electromagnetic disturbance 2.1.16 electromagnetic shielding a shielding to reduce the penetration of alternating electromagnetic field into a designated area through conducting material. 2.1.17 electromagnetic shielding enclosure the building space body used exclusively for attenuating and isolating the energy from external or internal electric and magnetic fields 2.1.18 cut-off waveguide vent the device combining cut-off waveguide and vent, which allows for ventilation and can attenuate electromagnetic wave within a certain frequency range 2.1.19 modular electromagnetic shielding enclosure electromagnetic shielding enclosure with dismountable structure, which is built with module board of pre-shaped shielding enclosure, structural member, shielding component and the like via assembly on construction site according to design requirements 2.1.20 welded electromagnetic shielding enclosure electromagnetic shielding enclosure with fixed structure, whose main structure is constructed by site welding 2.1.21 remote power panel (RPP) equipment for providing distribution arrangement for cabinets arrayed in a rows or divided according to functional area 2.1.22 horizontal distribution area cabinet horizontal distribution area equipment for providing network service for cabinets arrayed in a rows or divided according to functional area 2.1.23 intelligent cabling management system a set of complete soft/hardware integration system, which realizes the intelligent management for tracing, recording and reporting cabling system and network equipment connection state by monitoring the connection attribute of electronic distribution equipment port in real time 2.1.24 static state air conditioning system of computer room is under normal operating state; indoor temperature and dew point temperature meet the operating requirement of electronic information equipment, but electronic information equipment does not operate 2.1.25 dynamic state air conditioning system and electronic information equipment of computer room are under normal operating state and there are relevant personnel in the room 2.1.26 stop condition air conditioning system of computer room and auxiliary area are under normal operating state; indoor temperature and relative humidity meet stop requirements of electronic information equipment 2.1.27 electrostatic leakage the phenomenon that the electrostatic charge on electrified body disappeared partially or completely through the interior or surface of electrified body
Contents of GB 50174-2017
1 General Provisions 2 Terms and Symbols 2.1 Terms 2.2 Symbols 3 Rating Classification and Required Features 3.1 Rating Classification 3.2 Required Features 4 Site Selection and Equipment Layout 4.1 Site Selection 4.2 Composition 4.3 Equipment Layout 5 Environmental Requirement 5.1 Temperature, Dew Point Temperature and Airborne Particle Concentration 5.2 Noise, Electromagnetic Interference, Vibration and Static Electricity 6 Building and Structure 6.1 General Requirements 6.2 People Flow, Goods Flow, Entrances and Exits 6.3 Retaining Structure Thermal Design and Energy Saving Measure 6.4 Interior Decoration 7 Air Conditioning 7.1 General Requirements 7.2 Thermal Load Calculation 7.3 Airflow Management 7.4 System Design 7.5 Equipment Selection 8 Electrical Systems 8.1 Power Supply and Distribution 8.2 Lighting 8.3 Electrostatic Discharge Protection 8.4 Lightning Protection and Earthing 9 Electromagnetic Shielding 9.1 General Requirements 9.2 Shielding Structure 9.3 Shielding Objects 10 Network and Cabling System 10.1 Network System 10.2 Cabling System 11 Intelligent System 11.1 General Requirements 11.2 Environment and Equipment Monitoring System 11.3 Security System 11.4 Enterprise Command Center 12 Water Supply and Drainage 12.1 General Requirements 12.2 Piping Layout 13 Fire Protection and Safety 13.1 General Requirements 13.2 Fire Prevention and Evacuation 13.3 Fire Protection Facilities 13.4 Safety Measures Annex A Technical Requirements for Data Center Ratings Explanation of Wording in This Code List of Quoted Standards