2023-3-20 3.238.250.73
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 50016-2014(2018)-Provisions
GB 50016-2014(2018)-Provisions   Provisions of Code for Fire Protection Design of Buildings (English Version)
Standard No.: GB 50016-2014(2018)-Provisions Status:valid remind me the status change

Email:

Language:English File Format:PDF
Word Count: 131000 words Price(USD):3930.0 remind me the price change

Email:

Implemented on:2015-5-1 Delivery: via email in 1~10 business day
,,
Standard No.: GB 50016-2014(2018)-Provisions
English Name: Provisions of Code for Fire Protection Design of Buildings
Chinese Name: 建筑设计防火规范 之 条文说明
Professional Classification: GB    National Standard
Issued on: 2014-08-27
Implemented on: 2015-5-1
Status: valid
Language: English
File Format: PDF
Word Count: 131000 words
Price(USD): 3930.0
Delivery: via email in 1~10 business day
GB 50016-2014(2018)- Provisions of Code for Fire Protection Design of Buildings 4 Category A, B, C liquid and gas tanks (tank farm) and stackyard for combustibles 4.1 General requirements 4.1.1 Combined with the development needs of cities in China, this provision stipulates the arrangement requirements of Category A, B and C liquid tank farm, LPG tank farm, combustible and combustion-supporting gas tank farm, stackyard for combustibles, etc., so as to ensure the safety of cities and residential areas. The open stackyards for combustibles in this Code includes the stackyards for straw, reed, tobacco leaves, herbs, hemp, bagasse, wood, pulp raw materials, coal, etc. Once a fire happens in these places, it is difficult to extinguish the fire and the harm range is large. In the actual site selection, these places shall be arranged as far as possible in the city and at the windward side with the annual minimum frequency; when there are difficulties, try to choose the windward side with the annual minimum frequency in this area or this unit throughout the year, so as to prevent the fire from harming other buildings or combustibles stacks. Category A, B and C liquid tanks (tank farm) should be arranged in the zone with low terrain as far as possible. Where they are arranged in the zone with high terrain, security facilities such as strengthening fire dikes or adding additional protective walls should be taken; because of the characteristics of high relative density, large gasification volume and low explosion limit, the LPG tank farm should be as far away as possible from residential areas, industrial enterprises and areas with important public buildings such as theaters, cinemas, gymnasiums, schools and hospitals, and be arranged separately in well-ventilated areas. In these places specified in this provision, the burning speed is fast with strong radiant heat, and it is difficult to put out the fire. The fire often lasts for a long time, and some places still have explosion danger, which endangers a large range and consumes a large amount of water for saving and cooling. Therefore, the source and guarantee degree of fire water should be fully considered in site selection. 4.1.2 This provision is compulsory. This provision is mainly aimed at Category A liquid with low flash point, which is sensitive to temperature and it is specially necessary to prevent overpressure explosion and fire due to open storage in hot climate in summer. 4.1.3 This provision is compulsory. When liquefied petroleum gas leaks, its gasification volume is large and diffusion range is wide, and it is prone to accumulate and cause serious disasters. In addition to comprehensive consideration in site selection, measures should be taken to avoid and reduce the harm of tank explosion or leakage to surrounding buildings as far as possible. Setting up the protective walls can prevent leakage and outflow of storage tanks from endangering other buildings. The height of the protective wall is not greater than 1.0m, which has little influence on ventilation and will not accumulate air. The relevant specifications of the United States and the former Soviet Union all have corresponding requirements for setting up protective walls in tank farms. Fire dikes are also set in every LPG tank farm and every storage tank in Japan. Therefore, this provision requires that a protective wall with a height of not less than 1.0m should be set in the LPG tank farm, but the distance between the tank and the protective wall should be considered as half of its length for horizontal tanks and half of its diameter for spherical tanks. The fire separation distance between LPG tank and surrounding buildings shall meet the relevant requirements of 4.4 of this Code and the current national standard GB 50028 Code for design of city gas engineering. 4.1.4 If the loading and unloading facilities are located in or near the tank area, when the storage tank leaks, vehicles enter or loading and unloading operations are carried out, there is a danger of fire caused by explosion. In the design of these places, partition according to function shall be considered first, and the storage tanks should be arranged separately from their loading and unloading facilities and auxiliary management facilities, so as to take isolation measures and manage. 4.2 Fire separation distance of Category A, B, C liquid tanks (tank farm) This provision is mainly aimed at Category A, B and C liquid tanks (tank farm) in industrial enterprises and independently built. In order to facilitate the implementation of this Code and the coordination between standards, the arrangement of storage tanks in professional oil depots and the fire separation distance between storage tanks and buildings inside and outside the depots shall meet the requirements of GB 50074 Code for design of oil depot. 4.2.1 This provision is compulsory. This provision specifies the fire separation distance between Category A, B and C liquid tanks and barreled Category B and C liquid stackyards and other buildings (1) The maximum total capacity of Category A, B and C liquid tanks and barreled Category B and C liquid stackyards is determined according to the capacity of combustible liquid storage affiliated to factories and enterprises and other Category A, B and C liquid tanks and storages. The fire separation distance specified in Table 4.2.1 is mainly put forward according to fire examples, basically meeting the requirements of fire fighting and some current practical practices. If a 30m3 horizontal oil tank explodes and catches fire, it can shatter the windows and doors with a distance of 15m, and the radiant heat may ignite the combustibles with a distance of 12m. According to the practical experience of fighting oil tanks, when the oil tanks (pools) catch fire, they burn violently and have strong radiant heat. To meet the fire fighting needs, there shall be a safe distance of at least 12~15m away if the small tanks catch fire, and 15~20m in the case of relative large tank. (2) For a tank farm where Category A, B and C liquids may be stored at the same time, when determining the fire separation distance between tank farms, it is necessary to convert the capacity of different combustible liquids into the capacity of the same type of liquid (which can be converted into Category A, B or C liquids), and then determine it according to those specified in Table 4.2.1 of this Code . (3) Explanation on the notes in Table 4.2.1. Note 3: Because the fixed roof tank farm and semi-open stackyard of Category A, B and C liquids and barreled Category B and C liquid stackyard have a great influence on each other with Category A factory buildings (storage)/civil buildings in case of fire, the corresponding fire separation distance shall be increased by 25% on basis of those specified in Table 4.2.1. In case of oil leakage due to boil over or rupture in the above-mentioned storage tanks and stackyard, fire will be caused when encountering ignition sources, so the fire separation distance from open flames or sparking sites is increased by 25% on the basis of the requirements for the building with Class IV fire resistance in this table. Note 4: The fire separation distance between tank farm with floating roof or liquid tank farm with the flash point over 120℃ shall be decreased by 25% on basis of those specified in Table 4.2.1 relatively small fire hazard, and it should not be decreased as far as possible for high-rise buildings and their podium.
GB 50016-2014(2018)-Provisions is referred in:
*GB/T 21086-2007 Curtain Wall for Building
*GB 50015-2019 Standard for design of building water supply and drainage
*DL/T 5068-2006 Technical Code for Designing Chemistry of Thermal Power Plants
*DL/T 5352-2006 Technical code for designing high voltage electrical switchgear
*GB/T 37613-2019 Embedded channel steel
*GB/T 20801.1-2020 Pressure piping code—Industrial piping—Part 1:General
*GB 15577-2018 Safety regulations for dust explosion prevention and protection
*GB 50873-2013 Design code for piping of water supply and drainage in chemical industry
*GB 50013-2018 Code for design of outdoor water supply engineering
*GB 51283-2020 Fire protection standard for engineering design of fine chemical enterprise
*EJ/T 878-2011 Design criteria for independent spent fuel storage installation
*GB/T 35077-2018 Safety of machinery—Local exhaust ventilation system—Safety requirements
*GB 50454-2020 Standard for design of aero-engine test cell
*GB/T 20801.6-2020 Pressure piping code - Industrial piping - Part 6: Safeguarding
*HJ 1093-2020 Technical specifications for industrial organicwaste gas treatment by regenerative thermal oxidation
*DBJ/T 15-81-2011 Code for fire resistance design of concrete structures in buildings
*JGJ/T 331-2014 Technical Specification for Slip Resistance of Buildings Floor
*GB 50041-2020 Standard for design of boiler plant
*DBJ/T 15-148-2018 Technical specifications for metal roofing system in areas prone to strong winds
*HG 20571-2014 Code for Safety and Hygiene Design of Chemical Enterprise
*GB 51156-2015 Code for design of liquefied natural gas receiving terminal
*CECS 410-2015 Technical specification for stainless steel structures
*GB/T 40061-2021 Technical specification for liquid hydrogen production system
*GB 50074-2014 Code for design of oil depot
*JB/T 8856-2018 Dissolved acetylene systems
*JGJ 174-2010 Technical specification for multi-connected split air condition system
*DL/T 5054-2016 Code for design of steam water piping in thermal power plant
*GB 50352-2019 Unified standard for design of civil building
*GB 22128-2019 Technical specifications for end-of-life vehicles collecting and dismantling enterprises
*GB 51427-2021 Technical standard for auto tracking and targeting jet suppression system
*GB/T 33000-2016 Guideline of China occupational safety and health management system
*GB/T 50115-2019 Standard for design of industrrial television system
*GB 50414-2018 Standard for fire protection design of iron and steel metallurgy enterprises
*GB 50431-2020 Technical standard for belt conveyor engineering
*GB 50229-2019 Standard for design of fire protection for fossil fuel power plants and substations
*GB/T 21087-2020 Energy recovery ventilators for outdoor air handling
*GB 50019-2015 Code for Design of Heating Ventilation and Air Conditioning in Industrial Buildings
*SH 3501-2011 Construction and acceptance Specification for toxic and combustible medium steel piping engineering in petrochemical industry
*JGJ 66-2015 Code for Design of Museum Building
*GB 50174-2017 Code for design of electronic information systern room
*GB 50265-2022 Standard for pumping station design
*GB/T 26465-2021 Safety rules for the construction and installation of firefighters lifts
*GB 50005-2017 Standard for design of timber structures
*GB 50072-2021 Standard for design of cold store
*GB 50072-2010 Code for design of cold store
*DL/T 5056-2007 Technical code of general plan design for substation
*GB/T 16507.8-2013 Water-tube Boilers - Part 8: Installation and Operation
*GB/T 16507.8-2022 Water-tube boilers—Part 8: Installation and operation
*DB11/755-2010 Safety Code for Construction and Storage of Dangerous Chemicals Warehouse
*GB 15603-2022 General rules for the hazardous chemicals warehouse storage
Code of China
Standard
GB 50016-2014(2018)-Provisions  Provisions of Code for Fire Protection Design of Buildings (English Version)
Standard No.GB 50016-2014(2018)-Provisions
Statusvalid
LanguageEnglish
File FormatPDF
Word Count131000 words
Price(USD)3930.0
Implemented on2015-5-1
Deliveryvia email in 1~10 business day
Detail of GB 50016-2014(2018)-Provisions
Standard No.
GB 50016-2014(2018)-Provisions
English Name
Provisions of Code for Fire Protection Design of Buildings
Chinese Name
建筑设计防火规范 之 条文说明
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
Issued on
2014-08-27
Implemented on
2015-5-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
131000 words
Price(USD)
3930.0
Keywords
GB 50016-2014(2018)-Provisions, GB/T 50016-2014(2018)-Provisions, GBT 50016-2014(2018)-Provisions, GB50016-2014(2018)-Provisions, GB 50016, GB50016, GB/T50016-2014(2018)-Provisions, GB/T 50016, GB/T50016, GBT50016-2014(2018)-Provisions, GBT 50016, GBT50016
Introduction of GB 50016-2014(2018)-Provisions
GB 50016-2014(2018)- Provisions of Code for Fire Protection Design of Buildings 4 Category A, B, C liquid and gas tanks (tank farm) and stackyard for combustibles 4.1 General requirements 4.1.1 Combined with the development needs of cities in China, this provision stipulates the arrangement requirements of Category A, B and C liquid tank farm, LPG tank farm, combustible and combustion-supporting gas tank farm, stackyard for combustibles, etc., so as to ensure the safety of cities and residential areas. The open stackyards for combustibles in this Code includes the stackyards for straw, reed, tobacco leaves, herbs, hemp, bagasse, wood, pulp raw materials, coal, etc. Once a fire happens in these places, it is difficult to extinguish the fire and the harm range is large. In the actual site selection, these places shall be arranged as far as possible in the city and at the windward side with the annual minimum frequency; when there are difficulties, try to choose the windward side with the annual minimum frequency in this area or this unit throughout the year, so as to prevent the fire from harming other buildings or combustibles stacks. Category A, B and C liquid tanks (tank farm) should be arranged in the zone with low terrain as far as possible. Where they are arranged in the zone with high terrain, security facilities such as strengthening fire dikes or adding additional protective walls should be taken; because of the characteristics of high relative density, large gasification volume and low explosion limit, the LPG tank farm should be as far away as possible from residential areas, industrial enterprises and areas with important public buildings such as theaters, cinemas, gymnasiums, schools and hospitals, and be arranged separately in well-ventilated areas. In these places specified in this provision, the burning speed is fast with strong radiant heat, and it is difficult to put out the fire. The fire often lasts for a long time, and some places still have explosion danger, which endangers a large range and consumes a large amount of water for saving and cooling. Therefore, the source and guarantee degree of fire water should be fully considered in site selection. 4.1.2 This provision is compulsory. This provision is mainly aimed at Category A liquid with low flash point, which is sensitive to temperature and it is specially necessary to prevent overpressure explosion and fire due to open storage in hot climate in summer. 4.1.3 This provision is compulsory. When liquefied petroleum gas leaks, its gasification volume is large and diffusion range is wide, and it is prone to accumulate and cause serious disasters. In addition to comprehensive consideration in site selection, measures should be taken to avoid and reduce the harm of tank explosion or leakage to surrounding buildings as far as possible. Setting up the protective walls can prevent leakage and outflow of storage tanks from endangering other buildings. The height of the protective wall is not greater than 1.0m, which has little influence on ventilation and will not accumulate air. The relevant specifications of the United States and the former Soviet Union all have corresponding requirements for setting up protective walls in tank farms. Fire dikes are also set in every LPG tank farm and every storage tank in Japan. Therefore, this provision requires that a protective wall with a height of not less than 1.0m should be set in the LPG tank farm, but the distance between the tank and the protective wall should be considered as half of its length for horizontal tanks and half of its diameter for spherical tanks. The fire separation distance between LPG tank and surrounding buildings shall meet the relevant requirements of 4.4 of this Code and the current national standard GB 50028 Code for design of city gas engineering. 4.1.4 If the loading and unloading facilities are located in or near the tank area, when the storage tank leaks, vehicles enter or loading and unloading operations are carried out, there is a danger of fire caused by explosion. In the design of these places, partition according to function shall be considered first, and the storage tanks should be arranged separately from their loading and unloading facilities and auxiliary management facilities, so as to take isolation measures and manage. 4.2 Fire separation distance of Category A, B, C liquid tanks (tank farm) This provision is mainly aimed at Category A, B and C liquid tanks (tank farm) in industrial enterprises and independently built. In order to facilitate the implementation of this Code and the coordination between standards, the arrangement of storage tanks in professional oil depots and the fire separation distance between storage tanks and buildings inside and outside the depots shall meet the requirements of GB 50074 Code for design of oil depot. 4.2.1 This provision is compulsory. This provision specifies the fire separation distance between Category A, B and C liquid tanks and barreled Category B and C liquid stackyards and other buildings (1) The maximum total capacity of Category A, B and C liquid tanks and barreled Category B and C liquid stackyards is determined according to the capacity of combustible liquid storage affiliated to factories and enterprises and other Category A, B and C liquid tanks and storages. The fire separation distance specified in Table 4.2.1 is mainly put forward according to fire examples, basically meeting the requirements of fire fighting and some current practical practices. If a 30m3 horizontal oil tank explodes and catches fire, it can shatter the windows and doors with a distance of 15m, and the radiant heat may ignite the combustibles with a distance of 12m. According to the practical experience of fighting oil tanks, when the oil tanks (pools) catch fire, they burn violently and have strong radiant heat. To meet the fire fighting needs, there shall be a safe distance of at least 12~15m away if the small tanks catch fire, and 15~20m in the case of relative large tank. (2) For a tank farm where Category A, B and C liquids may be stored at the same time, when determining the fire separation distance between tank farms, it is necessary to convert the capacity of different combustible liquids into the capacity of the same type of liquid (which can be converted into Category A, B or C liquids), and then determine it according to those specified in Table 4.2.1 of this Code . (3) Explanation on the notes in Table 4.2.1. Note 3: Because the fixed roof tank farm and semi-open stackyard of Category A, B and C liquids and barreled Category B and C liquid stackyard have a great influence on each other with Category A factory buildings (storage)/civil buildings in case of fire, the corresponding fire separation distance shall be increased by 25% on basis of those specified in Table 4.2.1. In case of oil leakage due to boil over or rupture in the above-mentioned storage tanks and stackyard, fire will be caused when encountering ignition sources, so the fire separation distance from open flames or sparking sites is increased by 25% on the basis of the requirements for the building with Class IV fire resistance in this table. Note 4: The fire separation distance between tank farm with floating roof or liquid tank farm with the flash point over 120℃ shall be decreased by 25% on basis of those specified in Table 4.2.1 relatively small fire hazard, and it should not be decreased as far as possible for high-rise buildings and their podium.
Contents of GB 50016-2014(2018)-Provisions
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Foryou Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 50016-2014(2018)-Provisions, GB/T 50016-2014(2018)-Provisions, GBT 50016-2014(2018)-Provisions, GB50016-2014(2018)-Provisions, GB 50016, GB50016, GB/T50016-2014(2018)-Provisions, GB/T 50016, GB/T50016, GBT50016-2014(2018)-Provisions, GBT 50016, GBT50016