2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB/T 1576-2008
GB/T 1576-2008   Water quality for industrial boilers (English Version)
Standard No.: GB/T 1576-2008 Status:superseded remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 13000 words Translation Price(USD):320.0 remind me the price change

Email:

Implemented on:2009-3-1 Delivery: via email in 1 business day

→ → →

,2018-12-1,2009-3-1,141138181855462401047EFD9797B
Standard No.: GB/T 1576-2008
English Name: Water quality for industrial boilers
Chinese Name: 工业锅炉水质
Chinese Classification: J75    Heat-exchange equipment
Professional Classification: GB    National Standard
Source Content Issued by: AQSIQ; SAC
Issued on: 2008-9-26
Implemented on: 2009-3-1
Status: superseded
Superseded by:GB/T 1576-2018 Water quality for industrial boilers
Superseded on:2018-12-1
Superseding:GB 1576-2001 Water quality for industrial boilers
Target Language: English
File Format: PDF
Word Count: 13000 words
Translation Price(USD): 320.0
Delivery: via email in 1 business day
1 Scope This standard specifies water quality criteria of industrial boiler in operation. This standard is applicable to fixed steam boiler and steam-water multifunctional boiler with water as medium whose nominal outlet steam pressure is less than 3.8 MPa, as well as fixed pressurized hot water boiler and constant-pressure hot water bolier with water as medium. This standard is not applicable to boilers made of aluminium products. 2 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments (excluding amending error in the text) to, or revisions of, any of these publications do not be applied. However, the parties whose enter into agreement according to these specifications are encouraged to research whether the latest editions of these references are applied or not. For undated references, the latest edition of the normative document is applicable to these specifications. GB/T 601 Chemical Reagent -- Preparations of Standard Volumetric Solutions GB/T 603 Chemical Reagent -- Preparations of Reagent Solutions for Use in Test Method (GB/T 603-2002, ISO 6353-1: 1982, Rcagents for Chemical Analysis -- Part 1: General Test Methods, NEQ) GB/T 6682 Water for Analytical Laboratory Use -- Specification and Test Methods (GB/T 6682-2008, ISO 3696: 1987, MOD) GB/T 6903 Analysis of Water Used in Boil and Cooling System - General Rule GB/T 6904 Water Used in Industrial Circulating Cooling System and Boiler -- Determination of pH GB/T 6907 Analysis of Water Used in Boil and Cooling System -- The Sampling Method of Water GB/T 6908 Analysis of Water Used in Boil and Cooling System -- Determination of Electrical Conductivity GB/T 6909 Analysis of Water Used in Boiler and Cooling System -- Determination of Hardness GB/T 6913 Analysis of Water Used in Boiler and Cooling System -- Determination of Phosphate (GB/T 6913-2008, ISO 6878: 2004, Water quality -- Determination of phosphorus -- Ammonium molybdate spectrometric method, NEQ) GB/T 12145 Quality Criterion of Water and Steam for Generating Unit and Steam Power Epuipment GB/T 12151 Analysis Method of Boiler Water and Cooling Water - Determination of Turbidity (Formazin turbidity) GB/T 12152 Water for Boiler and Cooling System -- Determination of Mineral Oil GB/T 12157 Water for Industrial Circulating Cooling System and Boiler -- Determination of Dissolved Oxygen (GB/T 12157-2007, ISO 5813: 1983, Water quality -- Determination of dissolved oxygen -- Iodimetric method, NEQ) GB/T 15453 Water for Industrial Circulating Cooling System and Boiler -- Determination of Chloridion DL/T 502.1 Analytical Methods of Steam and Water in Power Plants -- Part 1: General Rules DL/T 502.25 Analytical Methods of Steam and Water in Power Plants -- Part 25: Determination of Iron (Spectrometric method using sulphosalicylic acid) 3 Terms and Definitions For the purposes of this standard, the following terms and definitions apply. 3.1 Raw water The water not applied any treatment. 3.2 Softened water The water whose all or a majority of calcium and magnesium ions are removed. 3.3 Demineralized water The general name of finished water whose all or a majority of impurities like suspended matter, inorganic matter and positive ions are removed through effective technology treatment. 3.4 Make-up water The treated water that is used to supplement boiler blowdown and steam-water loss. 3.5 Boiler feed water The water directly entering boiler, which generally consists of make-up water, back water and drainage. 3.6 Boiler water The water that raise steam or becomes hot by absorbing heat in operating boiler. 3.7 Back water The water that steam and hot water made by boiler come back to boiler feed water after doing works or heat exchange. 3.8 Internal chemical boiler water treatment The method that a certain amount of chemicals is dosed into boiler in order to avoid and reduce boiler scalling or corrosion. 3.9 External boiler water treatment The method that harmful impurity caused by boiler operation is applied with necessary technology before the raw water enters into the boiler. 4 Water Quality Ccriteria 4.1 Water quality of natural cycle steam boiler and steam-water multifunctional boiler 4.1.1 Water quality of natural-cycle steam boiler and steam-water multifunctional boiler adopting external boiler water treatment Water quality of boiler feed water and boiler water for natural-cycle steam boiler and steam-water multifunctional boiler adopting external boiler water treatment shall meet the requirements specified in Table 1.
1 Scope 2 Normative References 3 Terms and Definitions 4 Water Quality Ccriteria 5 Water Analysis Method Appendix A (Normative) Determination of turbidity (turbidometer method) Appendix B (Normative) Determination of Dissolved Oxygen (Oxygen Electrode Method) Appendix C (Normative) Determination of Oil (Gravimetric Method) Appendix D (Normative) Determination of Dissolved Solid Matter (Gravimetric Method) Appendix E (Normative) Indirect Determination of Dissolved Solid Matter of Boiler Water Appendix F (Normative) Determination of Phosphate (Phosphomolybdate Blue Spectrophotometry) Annex G (Normative) Determination of Chloride (Ammonium Thiocyanate Titration) Appendix H (Normative) Determination of Alkalinity (Neutralization Titration) Appendix I (Normative) Determination of Sulfite (Iodometric Method)
Referred in GB/T 1576-2008:
*GB/T 601-2016 Chemical Reagent - Preparations of Standard Volumetric Solutions
*GB/T 603-2002 Chemical Reagent – Preparations of Reagent Solution for Use in Tes
*GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods
*GB/T 6903-2022 Analysis of water used in boiler and cooling system—General rule
*GB/T 6904-2008 Water used in industrial circulating cooling system and boiler - Determination of pH
*GB/T 6907-2022 Analysis of water used in boiler and cooling system—Sampling method of water
*GB/T 6908-2018 Analysis of water used in boiler and cooling system—Determination of electrical conductivity
*GB/T 6909-2018 Analysis of water used in boiler and cooling system—Determination of hardness
*GB/T 6913-2008 Analysis of water used in boiler and cooling system - Determination of phosphorus
*GB/T 12145-2016 Quality criterion of water and steam for power plant and steam-generating equipment
*GB/T 12151-2005 Analysis of water used in boiler and cooling system - Determination of turbidity - Formazine turbidity
*GB/T 12152-2007 Water for boiler and cooling system—Determination of mineral oil
*GB/T 12157-2022 Determination of dissolved oxygen in water for industrial circulating cooling system and boiler
*GB/T 15453-2018 Determination of chloride in water for industrial circulating cooling system and boiler
*DL/T 502.1-2006 Analytical methods of steam and water in power plants Part 1: General rule
*DL/T 502.25-2019 Analytical methods of steam and water in power plants一Part 25: Determination of iron
GB/T 1576-2008 is referred in:
* CJJ 34-2010 Design Code for City Heating Network
* CJJ 34-2010 Design Code for City Heating Network
* GB 50195-2013 Design code for producer gas station
* GB/T 16508.1-2013 Shell Boilers - Part 1: General Requirements
* GB/T 16508.8-2013 Shell Boilers - Part 8: Operation
* GB/T 16508.7-2013 Shell Boilers - Part 7: Installation
* GB/T 16508.5-2013 Shell Boilers - Part 5: Safety Appurtenances and Instruments
* GB/T 16508.3-2013 Shell boilers—Part 3:Design and strength calculation
* GBT16508.1~16508.8-2013 Shell boilers (Collection)
* GB 50019-2015 Code for Design of Heating Ventilation and Air Conditioning in Industrial Buildings
* GB/T 29044-2012 采暖空调系统水质
Code of China
Standard
GB/T 1576-2008  Water quality for industrial boilers (English Version)
Standard No.GB/T 1576-2008
Statussuperseded
LanguageEnglish
File FormatPDF
Word Count13000 words
Price(USD)320.0
Implemented on2009-3-1
Deliveryvia email in 1 business day
Detail of GB/T 1576-2008
Standard No.
GB/T 1576-2008
English Name
Water quality for industrial boilers
Chinese Name
工业锅炉水质
Chinese Classification
J75
Professional Classification
GB
ICS Classification
Issued by
AQSIQ; SAC
Issued on
2008-9-26
Implemented on
2009-3-1
Status
superseded
Superseded by
GB/T 1576-2018 Water quality for industrial boilers
Superseded on
2018-12-1
Abolished on
Superseding
GB 1576-2001 Water quality for industrial boilers
Language
English
File Format
PDF
Word Count
13000 words
Price(USD)
320.0
Keywords
GB/T 1576-2008, GB 1576-2008, GBT 1576-2008, GB/T1576-2008, GB/T 1576, GB/T1576, GB1576-2008, GB 1576, GB1576, GBT1576-2008, GBT 1576, GBT1576
Introduction of GB/T 1576-2008
1 Scope This standard specifies water quality criteria of industrial boiler in operation. This standard is applicable to fixed steam boiler and steam-water multifunctional boiler with water as medium whose nominal outlet steam pressure is less than 3.8 MPa, as well as fixed pressurized hot water boiler and constant-pressure hot water bolier with water as medium. This standard is not applicable to boilers made of aluminium products. 2 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments (excluding amending error in the text) to, or revisions of, any of these publications do not be applied. However, the parties whose enter into agreement according to these specifications are encouraged to research whether the latest editions of these references are applied or not. For undated references, the latest edition of the normative document is applicable to these specifications. GB/T 601 Chemical Reagent -- Preparations of Standard Volumetric Solutions GB/T 603 Chemical Reagent -- Preparations of Reagent Solutions for Use in Test Method (GB/T 603-2002, ISO 6353-1: 1982, Rcagents for Chemical Analysis -- Part 1: General Test Methods, NEQ) GB/T 6682 Water for Analytical Laboratory Use -- Specification and Test Methods (GB/T 6682-2008, ISO 3696: 1987, MOD) GB/T 6903 Analysis of Water Used in Boil and Cooling System - General Rule GB/T 6904 Water Used in Industrial Circulating Cooling System and Boiler -- Determination of pH GB/T 6907 Analysis of Water Used in Boil and Cooling System -- The Sampling Method of Water GB/T 6908 Analysis of Water Used in Boil and Cooling System -- Determination of Electrical Conductivity GB/T 6909 Analysis of Water Used in Boiler and Cooling System -- Determination of Hardness GB/T 6913 Analysis of Water Used in Boiler and Cooling System -- Determination of Phosphate (GB/T 6913-2008, ISO 6878: 2004, Water quality -- Determination of phosphorus -- Ammonium molybdate spectrometric method, NEQ) GB/T 12145 Quality Criterion of Water and Steam for Generating Unit and Steam Power Epuipment GB/T 12151 Analysis Method of Boiler Water and Cooling Water - Determination of Turbidity (Formazin turbidity) GB/T 12152 Water for Boiler and Cooling System -- Determination of Mineral Oil GB/T 12157 Water for Industrial Circulating Cooling System and Boiler -- Determination of Dissolved Oxygen (GB/T 12157-2007, ISO 5813: 1983, Water quality -- Determination of dissolved oxygen -- Iodimetric method, NEQ) GB/T 15453 Water for Industrial Circulating Cooling System and Boiler -- Determination of Chloridion DL/T 502.1 Analytical Methods of Steam and Water in Power Plants -- Part 1: General Rules DL/T 502.25 Analytical Methods of Steam and Water in Power Plants -- Part 25: Determination of Iron (Spectrometric method using sulphosalicylic acid) 3 Terms and Definitions For the purposes of this standard, the following terms and definitions apply. 3.1 Raw water The water not applied any treatment. 3.2 Softened water The water whose all or a majority of calcium and magnesium ions are removed. 3.3 Demineralized water The general name of finished water whose all or a majority of impurities like suspended matter, inorganic matter and positive ions are removed through effective technology treatment. 3.4 Make-up water The treated water that is used to supplement boiler blowdown and steam-water loss. 3.5 Boiler feed water The water directly entering boiler, which generally consists of make-up water, back water and drainage. 3.6 Boiler water The water that raise steam or becomes hot by absorbing heat in operating boiler. 3.7 Back water The water that steam and hot water made by boiler come back to boiler feed water after doing works or heat exchange. 3.8 Internal chemical boiler water treatment The method that a certain amount of chemicals is dosed into boiler in order to avoid and reduce boiler scalling or corrosion. 3.9 External boiler water treatment The method that harmful impurity caused by boiler operation is applied with necessary technology before the raw water enters into the boiler. 4 Water Quality Ccriteria 4.1 Water quality of natural cycle steam boiler and steam-water multifunctional boiler 4.1.1 Water quality of natural-cycle steam boiler and steam-water multifunctional boiler adopting external boiler water treatment Water quality of boiler feed water and boiler water for natural-cycle steam boiler and steam-water multifunctional boiler adopting external boiler water treatment shall meet the requirements specified in Table 1.
Contents of GB/T 1576-2008
1 Scope 2 Normative References 3 Terms and Definitions 4 Water Quality Ccriteria 5 Water Analysis Method Appendix A (Normative) Determination of turbidity (turbidometer method) Appendix B (Normative) Determination of Dissolved Oxygen (Oxygen Electrode Method) Appendix C (Normative) Determination of Oil (Gravimetric Method) Appendix D (Normative) Determination of Dissolved Solid Matter (Gravimetric Method) Appendix E (Normative) Indirect Determination of Dissolved Solid Matter of Boiler Water Appendix F (Normative) Determination of Phosphate (Phosphomolybdate Blue Spectrophotometry) Annex G (Normative) Determination of Chloride (Ammonium Thiocyanate Titration) Appendix H (Normative) Determination of Alkalinity (Neutralization Titration) Appendix I (Normative) Determination of Sulfite (Iodometric Method)
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 1576-2008, GB 1576-2008, GBT 1576-2008, GB/T1576-2008, GB/T 1576, GB/T1576, GB1576-2008, GB 1576, GB1576, GBT1576-2008, GBT 1576, GBT1576