2025-12-6 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 5413.38-2016
GB 5413.38-2016   National Food Safety Standard - Determination of freezing point in raw milk in food (English Version)
Standard No.: GB 5413.38-2016 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 2000 words Translation Price(USD):40.0 remind me the price change

Email:

Implemented on:2017-3-1 Delivery: via email in 1 business day

→ → →

,,2017-3-1,075A66B8E08DDFC41480649202386
Standard No.: GB 5413.38-2016
English Name: National Food Safety Standard - Determination of freezing point in raw milk in food
Chinese Name: 食品安全国家标准 生乳冰点的测定
Chinese Classification: X09    Hygiene, safety and labor protection
Professional Classification: GB    National Standard
Source Content Issued by: National Health and Family Planning Commission
Issued on: 2016-08-31
Implemented on: 2017-3-1
Status: valid
Superseding:GB 5413.38-2010 National Food Safety Standard - Determination of freezing point in raw milk
Target Language: English
File Format: PDF
Word Count: 2000 words
Translation Price(USD): 40.0
Delivery: via email in 1 business day
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard replaces GB 5413.38-2010 National Food Safety Standard - Determination of Freezing Point in Raw Milk. The following technical changes have been made with respect to GB 5413.38-2010: ——Theory is modified; ——"Reagents and Materials" is modified; ——"Standard solution C" is added in sodium chloride standard solution in "Reagents and Materials"; ——"Calibration C" and "quality control calibration" are added in "apparatus calibration" in "Analytical Procedure". National Food Safety Standard Determination of Freezing Point in Raw Milk 1 Scope This standard specifies the determination of freezing point in raw milk with thermistor cryoscope. This standard is applicable to the determination of freezing point in raw milk. 2 Theory Raw milk sample is cooled to moderate temperature; when the tested milk sample is cooled to -3℃, by releasing heat instantaneously, the sample crystallizes, then after the sample temperature achieves a balance and the temperature rising does not exceed 0.5℃ within 20s, the temperature is the freezing point of sample. 3 Reagents and Materials Unless otherwise specified, reagents of analytically-pure or above and Grade II water (defined in GB/T 6682) are adopted for the purposes of this method. 3.1 Reagents 3.1.1 Ethylene glycol (C2H6O2). 3.1.2 Sodium chloride (NaCl). 3.2 Reagent preparation 3.2.1 Sodium chloride (NaCl): after being grinded, sodium chloride is placed in drying oven and dried at 130℃±2℃ for more than 24h, and then cooled to room temperature in dryer. 3.2.2 Coolant: measure 330mL of ethylene glycol (3.1.1), put it into a 1,000mL volumetric flask, then bring the volume with water to the scale and shake well; the volume fraction of the solution is 33%. 3.3 Sodium chloride standard solution 3.3.1 Standard solution A: weigh 6.731g of sodium chloride (3.2.1), dissolve it into 1,000g±0.1g of water. Store standard solution in polyethylene plastic bottles of 250mL or less separately and put the bottles in about 5℃ refrigerator for cold storage for a storage life of two months. The freezing point of the solution is -400m℃. 3.3.2 Standard solution B: weigh 9.422g of sodium chloride (3.2.1), dissolve it into 1,000g±0.1g of water. Store standard solution in polyethylene plastic bottles of 250mL or less separately and put the bottles in about 5℃ refrigerator for cold storage for a storage life of two months. The freezing point of the solution is -557m℃. 3.3.3 Standard solution C: weigh 10.161g of sodium chloride (3.2.1), dissolve it into 1,000g±0.1g of water. Store standard solution in polyethylene plastic bottles of 250mL or less separately and put the bottles in about 5℃ refrigerator for cold storage for a storage life of two months. The freezing point of the solution is -600m℃. 4 Apparatuses 4.1 Analytical balance: with a sensitivity of 0.000 1g. 4.2 Thermistor cryoscope: detection device, cooling device, metal stirring rod, crystallization device (see Figure 1) and temperature demonstrator. a) Detection device and cooling device Temperature sensor is glass probe in diameter of 1.60mm±0.4mm and the resistance is between 3Ω and 30kΩ at 0℃. The material and diameter of sensor's rotating shaft shall ensure that the heat transfers to sample within 2.5×10-3J/s. When the probe is at the measuring position, the top of thermistor shall be placed at the central axis of sample tube and shall have equal distance to inner wall and to tube bottom (see Figure 1). The measurement resolution of temperature sensor and corresponding electronic circuit is 1m℃ at -600m℃~400m℃. Cooling device shall keep the temperature of coolant at -7℃±0.5℃ invariably. In: mm Key: 1——Push rod; 2——Sample tube; 3——Metal stirring rod; 4——Thermistor probe. Figure 1 Detection Device of Thermistor Cryoscope When the apparatus works normally, the linear error of the circulation system at any point within -600m℃ and -400m℃ shall not exceed 1m℃. b) Metal stirring rod Corrosion resistant, used for stirring sample in the cooling process. The vibration amplitude of metal stirring rod shall be adjusted according to the installation position of corresponding apparatus. During normal stirring, the metal rod shall not impact the glass sensor or sample tube wall. c) Crystallization device When the test sample reaches -3.0℃, start the mechanical vibration device and increase the vibration amplitude of metal stirring rod within 1s~2s at the time of crystallization to make the rod impact sample tube wall. 4.3 Drying oven: its temperature is controlled at 130℃±2℃. 4.4 Sample tube: borosilicate glass, 50.5mm±0.2mm in length, 16.0mm±0.2mm in external diameter and 13.7mm±0.3mm in internal diameter. 4.5 Weighing bottle. 4.6 Volumetric flask: 1,000mL, complying with the requirements of Grade A specified in GB/T 12806-2011. 4.7 Dryer: with silica gel hygrometer inside. 4.8 Pipette: 1mL~5mL. 4.9 Polyethylene bottle: with capacity of 250mL or less.
Foreword i 1 Scope 2 Theory 3 Reagents and Materials 4 Apparatuses 5 Analytical Procedures 6 Expression of Analytical Result 7 Accuracy 8 Others
Referred in GB 5413.38-2016:
*GB 51173-2016 Code for design of dewatering and draining in opne pit mine of coal industry
*GB 50243-2016 Code of Acceptance for Construction Quality of Ventilation and Air
*GB 51199-2016 Code for acceptance of construction engineering of telecommunication power supply facility
*GB 51205-2016 Code for design of PTA plant
*GB/T 33014.3-2016 Road vehicles-Component test methods for electrical/electronic disturbances from narrowband radiated electromagnetic energy- Part 3:Transverse electromagnetic(TEM)cell
*GB/T 19466.4-2016 Plastics一Differential scanning calorimetry(DSC)一 Part 4:Determination of specific heat capacity
*GB/T 6406-2016/XG1-2019 Superabrasive—Checking the grain size, includes Amendment 1
*GB/T 11835-2016 Rock wool,slag wool and its products for thermal insulation
*HG/T 20511-2014 Design code for signal alarm and interlock system engineering
*GB/T 17505-2016 Steel and steel products General technical delivery requirements
*GB 31604.47-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Fluorescent Brightener in Paper, Paperboards and Paper Products
GB 5413.38-2016 is referred in:
*CB/T 3196-1995 Flange Cast Steel Sea Water Stop Valve
*GB/T 33012.4-2016 Road vehicles-Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy-Part4:Bulk current injection(BCI)
*GB/T 1232.1-2016 Rubber,unvulcanized―Determinations using a shearing-disc viscometer―Part 1:Determination of Mooney viscosity
*GB 5009.236-2016 National Food Safety Standard - Animal and Vegetable Fats and Oils - Determination of Moisture and Volatile Matter
*GB 5009.181-2016 National Food Safety Standard - Determination of malondialdehyde in food
*GB 5009.228-2016 National Food Safety Standard - Determination of Volatile Basic Nitrogen in Food
*GB 31604.6-2016 National Food Safety Standard - Food Contact Materials and Articles -Determination of Ignition Residue in Resin
*GB 1886.26-2016 National Food Safety Standard - Food Additives - Paraffin
*GB 1886.187-2016 National Food Safety Standard - Food Additives - Sorbitol and Sorbitol Solution
*GB 1886.169-2016 National Food Safety Standard - Food Additives - Carrageenan
Code of China
Standard
GB 5413.38-2016  National Food Safety Standard - Determination of freezing point in raw milk in food (English Version)
Standard No.GB 5413.38-2016
Statusvalid
LanguageEnglish
File FormatPDF
Word Count2000 words
Price(USD)40.0
Implemented on2017-3-1
Deliveryvia email in 1 business day
Detail of GB 5413.38-2016
Standard No.
GB 5413.38-2016
English Name
National Food Safety Standard - Determination of freezing point in raw milk in food
Chinese Name
食品安全国家标准 生乳冰点的测定
Chinese Classification
X09
Professional Classification
GB
ICS Classification
Issued by
National Health and Family Planning Commission
Issued on
2016-08-31
Implemented on
2017-3-1
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
GB 5413.38-2010 National Food Safety Standard - Determination of freezing point in raw milk
Language
English
File Format
PDF
Word Count
2000 words
Price(USD)
40.0
Keywords
GB 5413.38-2016, GB/T 5413.38-2016, GBT 5413.38-2016, GB5413.38-2016, GB 5413.38, GB5413.38, GB/T5413.38-2016, GB/T 5413.38, GB/T5413.38, GBT5413.38-2016, GBT 5413.38, GBT5413.38
Introduction of GB 5413.38-2016
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. This standard replaces GB 5413.38-2010 National Food Safety Standard - Determination of Freezing Point in Raw Milk. The following technical changes have been made with respect to GB 5413.38-2010: ——Theory is modified; ——"Reagents and Materials" is modified; ——"Standard solution C" is added in sodium chloride standard solution in "Reagents and Materials"; ——"Calibration C" and "quality control calibration" are added in "apparatus calibration" in "Analytical Procedure". National Food Safety Standard Determination of Freezing Point in Raw Milk 1 Scope This standard specifies the determination of freezing point in raw milk with thermistor cryoscope. This standard is applicable to the determination of freezing point in raw milk. 2 Theory Raw milk sample is cooled to moderate temperature; when the tested milk sample is cooled to -3℃, by releasing heat instantaneously, the sample crystallizes, then after the sample temperature achieves a balance and the temperature rising does not exceed 0.5℃ within 20s, the temperature is the freezing point of sample. 3 Reagents and Materials Unless otherwise specified, reagents of analytically-pure or above and Grade II water (defined in GB/T 6682) are adopted for the purposes of this method. 3.1 Reagents 3.1.1 Ethylene glycol (C2H6O2). 3.1.2 Sodium chloride (NaCl). 3.2 Reagent preparation 3.2.1 Sodium chloride (NaCl): after being grinded, sodium chloride is placed in drying oven and dried at 130℃±2℃ for more than 24h, and then cooled to room temperature in dryer. 3.2.2 Coolant: measure 330mL of ethylene glycol (3.1.1), put it into a 1,000mL volumetric flask, then bring the volume with water to the scale and shake well; the volume fraction of the solution is 33%. 3.3 Sodium chloride standard solution 3.3.1 Standard solution A: weigh 6.731g of sodium chloride (3.2.1), dissolve it into 1,000g±0.1g of water. Store standard solution in polyethylene plastic bottles of 250mL or less separately and put the bottles in about 5℃ refrigerator for cold storage for a storage life of two months. The freezing point of the solution is -400m℃. 3.3.2 Standard solution B: weigh 9.422g of sodium chloride (3.2.1), dissolve it into 1,000g±0.1g of water. Store standard solution in polyethylene plastic bottles of 250mL or less separately and put the bottles in about 5℃ refrigerator for cold storage for a storage life of two months. The freezing point of the solution is -557m℃. 3.3.3 Standard solution C: weigh 10.161g of sodium chloride (3.2.1), dissolve it into 1,000g±0.1g of water. Store standard solution in polyethylene plastic bottles of 250mL or less separately and put the bottles in about 5℃ refrigerator for cold storage for a storage life of two months. The freezing point of the solution is -600m℃. 4 Apparatuses 4.1 Analytical balance: with a sensitivity of 0.000 1g. 4.2 Thermistor cryoscope: detection device, cooling device, metal stirring rod, crystallization device (see Figure 1) and temperature demonstrator. a) Detection device and cooling device Temperature sensor is glass probe in diameter of 1.60mm±0.4mm and the resistance is between 3Ω and 30kΩ at 0℃. The material and diameter of sensor's rotating shaft shall ensure that the heat transfers to sample within 2.5×10-3J/s. When the probe is at the measuring position, the top of thermistor shall be placed at the central axis of sample tube and shall have equal distance to inner wall and to tube bottom (see Figure 1). The measurement resolution of temperature sensor and corresponding electronic circuit is 1m℃ at -600m℃~400m℃. Cooling device shall keep the temperature of coolant at -7℃±0.5℃ invariably. In: mm Key: 1——Push rod; 2——Sample tube; 3——Metal stirring rod; 4——Thermistor probe. Figure 1 Detection Device of Thermistor Cryoscope When the apparatus works normally, the linear error of the circulation system at any point within -600m℃ and -400m℃ shall not exceed 1m℃. b) Metal stirring rod Corrosion resistant, used for stirring sample in the cooling process. The vibration amplitude of metal stirring rod shall be adjusted according to the installation position of corresponding apparatus. During normal stirring, the metal rod shall not impact the glass sensor or sample tube wall. c) Crystallization device When the test sample reaches -3.0℃, start the mechanical vibration device and increase the vibration amplitude of metal stirring rod within 1s~2s at the time of crystallization to make the rod impact sample tube wall. 4.3 Drying oven: its temperature is controlled at 130℃±2℃. 4.4 Sample tube: borosilicate glass, 50.5mm±0.2mm in length, 16.0mm±0.2mm in external diameter and 13.7mm±0.3mm in internal diameter. 4.5 Weighing bottle. 4.6 Volumetric flask: 1,000mL, complying with the requirements of Grade A specified in GB/T 12806-2011. 4.7 Dryer: with silica gel hygrometer inside. 4.8 Pipette: 1mL~5mL. 4.9 Polyethylene bottle: with capacity of 250mL or less.
Contents of GB 5413.38-2016
Foreword i 1 Scope 2 Theory 3 Reagents and Materials 4 Apparatuses 5 Analytical Procedures 6 Expression of Analytical Result 7 Accuracy 8 Others
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 5413.38-2016, GB/T 5413.38-2016, GBT 5413.38-2016, GB5413.38-2016, GB 5413.38, GB5413.38, GB/T5413.38-2016, GB/T 5413.38, GB/T5413.38, GBT5413.38-2016, GBT 5413.38, GBT5413.38