GB/T 43658.1-2024   Non-destructive testing—Radiographic inspection of corrosion and deposits in pipes by X and gamma rays—Part 1:Tangential radiographic inspection (English Version)
Standard No.: GB/T 43658.1-2024 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 18500 words Translation Price(USD):555.0 remind me the price change

Email:

Implemented on:2024-3-15 Delivery: via email in 1~3 business day

→ → →

,,2024-3-15,0D4C206043F1B6A61711512014693
Standard No.: GB/T 43658.1-2024
English Name: Non-destructive testing—Radiographic inspection of corrosion and deposits in pipes by X and gamma rays—Part 1:Tangential radiographic inspection
Chinese Name: 无损检测 管道腐蚀及沉积物X和伽马射线检测 第1部分:切向射线检测
Professional Classification: GB    National Standard
Source Content Issued by: SAMR; SAC
Issued on: 2024-3-15
Implemented on: 2024-3-15
Status: valid
Target Language: English
File Format: PDF
Word Count: 18500 words
Translation Price(USD): 555.0
Delivery: via email in 1~3 business day
GB/T 43658.1-2024 Non-destructive testing - Radiographic inspection of corrosion and deposits in pipes by X and gamma rays - Part 1: Tangential radiographic inspection 1 Scope This document specifies fundamental techniques of film and digital radiography with the object of enabling satisfactory and repeatable results to be obtained economically. The techniques are based on generally recognized practice and fundamental theory of the subject. This document applies to the radiographic examination of steel pipes for service induced flaws such as corrosion pitting, generalized corrosion and erosion. Besides its conventional meaning, “pipe” as used in this document is understood to cover other cylindrical bodies such as tubes, penstocks, boiler drums and pressure vessels. Weld inspection for typical welding process induced flaws is not covered, but weld inspection is included for corrosion/erosion type flaws. The pipes can be insulated or not, and can be assessed where loss of material due, for example, to corrosion or erosion is suspected either internally or externally. This document covers the tangential inspection technique for detection and through-wall sizing of wall loss, including with the source: a) on the pipe centre line; and b) offset from pipe centre line by the pipe radius. ISO 20769-2 covers double wall radiography, and note that the double wall double image technique is often combined with tangential radiography with the source on the pipe centre line. This document applies to tangential radiographic inspection using industrial radiographic film techniques, computed radiography (CR) and digital detector arrays (DDA). 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 9712 Non-destructive testing - Qualification and certification of NDT personnel Note: GB/T 9445-2015, Non-destructive testing - Qualification and certification of NDT personnel (ISO 9712:2012, IDT) ISO 11699-1 Non-destructive testing - Industrial radiographic film - Part 1: Classification of film systems for industrial radiography Note: GB/T 19348.1-2014, Non-destructive testing - Industrial radiographic film - Part 1: Classification of film systems for industrial radiography (ISO 11699-1:2008, MOD) ISO 11699-2 Non-destructive testing - Industrial radiographic films - Part 2: Control of film processing by means of reference values Note: GB/T 19348.2-2003, Non-destructive testing - Industrial radiographic films - Part 2: Control of film processing by means of reference values (ISO 11699-2:1998, IDT) ISO 16371-1 Non-destructive testing - Industrial computed radiography with storage phosphor imaging plates - Part 1: Classification of systems Note: GB/T 21355-2022, Non-destructive testing – Industrial computed radiography with storage phosphor imaging plates – Classification of systems (ISO 16371-1:2011, IDT) ISO 19232-5 Non-destructive testing - Image quality of radiographs - Part 5: Determination of the image unsharpness value using duplex wire-type image quality indicators Note: GB/T 23901.5-2019, Non-destructive testing - Image quality of radiographs - Part 5:Determination of the image quality unsharpness and basic spatial resolution value using duplex wire-type image quality indicators (ISO 19232-5:2018, IDT) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 actual wall thickness tact real thickness of the pipe wall which can differ from the nominal thickness 3.2 axial coverage Ld total axial extent of the evaluated section of the pipe radiograph measured on the detector (3.8) 3.3 axial coverage Lp total axial extent of the evaluated section of the pipe radiograph measured along the central axis of the pipe 3.4 basic spatial resolution SRbdetector smallest geometrical detail, which can be resolved in a digital image at a magnification equal to 1; corresponds to half of the measured image unsharpness in a digital image; corresponds to the effective pixel size (3.18) of the magnified image; and is determined from the smallest number of the duplex wire pair, which is not separable by visual inspection or from the smallest number of the duplex wire pair with less than 20 % modulation depth in a linearized profile Note 1: For this measurement, the duplex wire IQI is placed directly on the digital detector (3.8) array or imaging plate. Note 2: The measurements of SRbdetector and unsharpness are described in ISO 19232-5 And ASTM E2002. 3.5 basic spatial resolution SRbimage smallest geometrical detail, which can be resolved in a digital image at a magnification >1; corresponds to half of the measured image unsharpness in a digital image; corresponds to the effective pixel size (3.18) of the magnified image; and is determined from the smallest number of the duplex wire pair, which is not separable by visual inspection or from the smallest number of the duplex wire pair with less than 20 % modulation depth in a linearized profile Note: The measurements of SRbimage and unsharpness are described in ISO 19232-5 And ASTM E2002. 3.6 comparator C reference object of defined dimension c and material for dimensional calibration of a radiographic image 3.7 computed radiography CR complete system comprising a storage phosphor imaging plate (IP) (3.23) and a corresponding read-out unit (scanner or reader), which converts the information from the IP into a digital image and the control software of the read-out unit 3.8 detector D detection device, consisting of a NDT film system (see ISO 11699-1) or a digital radiography system using a CR system or a DDA system Note: Film systems and IPs can be used as flexible and curved detectors or in planar cassettes. 3.9 digital detector array DDA electronic device converting ionizing or penetrating radiation into a discrete array of analogue signals which are subsequently digitized and transferred to a computer for display as a digital image corresponding to the radiologic energy pattern imparted upon the input region of the device and the control software 3.10 imaged comparator dimension c′ dimension of the comparator (3.6) measured on the detector (3.8) 3.11 imaged outside diameter De′ nominal outside diameter of the pipe measured on the detector 3.12 maximum penetrated thickness wmax maximum thickness of material for a pipe which occurs for a tangent to the inner pipe surface 3.13 measured wall thickness tmeas thickness of the pipe wall as measured on the radiograph or digital image 3.14 nominal wall thickness t thickness of the pipe wall as given by the manufacturer, neglecting the manufacturing tolerances 3.15 normalized signal-to-noise ratio SNRN ratio of signal-to-noise, normalized by the basic spatial resolution, SRbimage, (3.5) as measured directly in the digital image and/or calculated from the measured SNRmeasured, by:
Referred in GB/T 43658.1-2024:
*GB/T 10288-2016/XG1-2020 Test method for down and feather,includes Amendment 1
*GB/T 17685-2016 Down and feather
*GB 19147-2016/XG1-2018 Automobile diesel fuels, includes Amendment 1
*GB 5009.265-2016 National Food Safety Standard-Determination of Polycyclic Aromatic Hydrocarbons in Foods
*GB/T 33339-2016 Vanadium flow battery system-Test method
*GB 25280-2016 Road traffic signal controller
*GB 4789.34-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Bifidobacterium
*GB 5009.267-2016 National Food Safety Standard Determination of Iodine in Foods
*GB 4789.6-2016 National food safety standard -Microbiological examination of food-Examination of diarrheogenic Escherichia coli
*GB 4789.4-2016 National food safety standard -Microbiological examination of food-Examination of salmonella
*GB 4789.3-2016 National Food Safety Standard-Food Microbiological Examination—Enumeration of Coliforms
*GB 4789.2-2016 National food safety standard -Microbiological examination of food: Aerobic plate count
*GB 4789.1-2016 National Food Safety Standard—Food Microbiological Examination—General
*GB 4789.12-2016 National Food Safety Standard—Food Microbiological Examination—Clostridium Botulinum and Botulinum Toxin
*GB 4789.10-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Staphylococcus Aureus
*GB 4789.35-2016 National food safety standard -Microbiological examination of food-Examination of lactic acid bacteria
*GB 4789.36-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Escherichia Coli O157:H7/MN
Code of China
Standard
GB/T 43658.1-2024  Non-destructive testing—Radiographic inspection of corrosion and deposits in pipes by X and gamma rays—Part 1:Tangential radiographic inspection (English Version)
Standard No.GB/T 43658.1-2024
Statusvalid
LanguageEnglish
File FormatPDF
Word Count18500 words
Price(USD)555.0
Implemented on2024-3-15
Deliveryvia email in 1~3 business day
Detail of GB/T 43658.1-2024
Standard No.
GB/T 43658.1-2024
English Name
Non-destructive testing—Radiographic inspection of corrosion and deposits in pipes by X and gamma rays—Part 1:Tangential radiographic inspection
Chinese Name
无损检测 管道腐蚀及沉积物X和伽马射线检测 第1部分:切向射线检测
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
SAMR; SAC
Issued on
2024-3-15
Implemented on
2024-3-15
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
Language
English
File Format
PDF
Word Count
18500 words
Price(USD)
555.0
Keywords
GB/T 43658.1-2024, GB 43658.1-2024, GBT 43658.1-2024, GB/T43658.1-2024, GB/T 43658.1, GB/T43658.1, GB43658.1-2024, GB 43658.1, GB43658.1, GBT43658.1-2024, GBT 43658.1, GBT43658.1
Introduction of GB/T 43658.1-2024
GB/T 43658.1-2024 Non-destructive testing - Radiographic inspection of corrosion and deposits in pipes by X and gamma rays - Part 1: Tangential radiographic inspection 1 Scope This document specifies fundamental techniques of film and digital radiography with the object of enabling satisfactory and repeatable results to be obtained economically. The techniques are based on generally recognized practice and fundamental theory of the subject. This document applies to the radiographic examination of steel pipes for service induced flaws such as corrosion pitting, generalized corrosion and erosion. Besides its conventional meaning, “pipe” as used in this document is understood to cover other cylindrical bodies such as tubes, penstocks, boiler drums and pressure vessels. Weld inspection for typical welding process induced flaws is not covered, but weld inspection is included for corrosion/erosion type flaws. The pipes can be insulated or not, and can be assessed where loss of material due, for example, to corrosion or erosion is suspected either internally or externally. This document covers the tangential inspection technique for detection and through-wall sizing of wall loss, including with the source: a) on the pipe centre line; and b) offset from pipe centre line by the pipe radius. ISO 20769-2 covers double wall radiography, and note that the double wall double image technique is often combined with tangential radiography with the source on the pipe centre line. This document applies to tangential radiographic inspection using industrial radiographic film techniques, computed radiography (CR) and digital detector arrays (DDA). 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 9712 Non-destructive testing - Qualification and certification of NDT personnel Note: GB/T 9445-2015, Non-destructive testing - Qualification and certification of NDT personnel (ISO 9712:2012, IDT) ISO 11699-1 Non-destructive testing - Industrial radiographic film - Part 1: Classification of film systems for industrial radiography Note: GB/T 19348.1-2014, Non-destructive testing - Industrial radiographic film - Part 1: Classification of film systems for industrial radiography (ISO 11699-1:2008, MOD) ISO 11699-2 Non-destructive testing - Industrial radiographic films - Part 2: Control of film processing by means of reference values Note: GB/T 19348.2-2003, Non-destructive testing - Industrial radiographic films - Part 2: Control of film processing by means of reference values (ISO 11699-2:1998, IDT) ISO 16371-1 Non-destructive testing - Industrial computed radiography with storage phosphor imaging plates - Part 1: Classification of systems Note: GB/T 21355-2022, Non-destructive testing – Industrial computed radiography with storage phosphor imaging plates – Classification of systems (ISO 16371-1:2011, IDT) ISO 19232-5 Non-destructive testing - Image quality of radiographs - Part 5: Determination of the image unsharpness value using duplex wire-type image quality indicators Note: GB/T 23901.5-2019, Non-destructive testing - Image quality of radiographs - Part 5:Determination of the image quality unsharpness and basic spatial resolution value using duplex wire-type image quality indicators (ISO 19232-5:2018, IDT) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 actual wall thickness tact real thickness of the pipe wall which can differ from the nominal thickness 3.2 axial coverage Ld total axial extent of the evaluated section of the pipe radiograph measured on the detector (3.8) 3.3 axial coverage Lp total axial extent of the evaluated section of the pipe radiograph measured along the central axis of the pipe 3.4 basic spatial resolution SRbdetector smallest geometrical detail, which can be resolved in a digital image at a magnification equal to 1; corresponds to half of the measured image unsharpness in a digital image; corresponds to the effective pixel size (3.18) of the magnified image; and is determined from the smallest number of the duplex wire pair, which is not separable by visual inspection or from the smallest number of the duplex wire pair with less than 20 % modulation depth in a linearized profile Note 1: For this measurement, the duplex wire IQI is placed directly on the digital detector (3.8) array or imaging plate. Note 2: The measurements of SRbdetector and unsharpness are described in ISO 19232-5 And ASTM E2002. 3.5 basic spatial resolution SRbimage smallest geometrical detail, which can be resolved in a digital image at a magnification >1; corresponds to half of the measured image unsharpness in a digital image; corresponds to the effective pixel size (3.18) of the magnified image; and is determined from the smallest number of the duplex wire pair, which is not separable by visual inspection or from the smallest number of the duplex wire pair with less than 20 % modulation depth in a linearized profile Note: The measurements of SRbimage and unsharpness are described in ISO 19232-5 And ASTM E2002. 3.6 comparator C reference object of defined dimension c and material for dimensional calibration of a radiographic image 3.7 computed radiography CR complete system comprising a storage phosphor imaging plate (IP) (3.23) and a corresponding read-out unit (scanner or reader), which converts the information from the IP into a digital image and the control software of the read-out unit 3.8 detector D detection device, consisting of a NDT film system (see ISO 11699-1) or a digital radiography system using a CR system or a DDA system Note: Film systems and IPs can be used as flexible and curved detectors or in planar cassettes. 3.9 digital detector array DDA electronic device converting ionizing or penetrating radiation into a discrete array of analogue signals which are subsequently digitized and transferred to a computer for display as a digital image corresponding to the radiologic energy pattern imparted upon the input region of the device and the control software 3.10 imaged comparator dimension c′ dimension of the comparator (3.6) measured on the detector (3.8) 3.11 imaged outside diameter De′ nominal outside diameter of the pipe measured on the detector 3.12 maximum penetrated thickness wmax maximum thickness of material for a pipe which occurs for a tangent to the inner pipe surface 3.13 measured wall thickness tmeas thickness of the pipe wall as measured on the radiograph or digital image 3.14 nominal wall thickness t thickness of the pipe wall as given by the manufacturer, neglecting the manufacturing tolerances 3.15 normalized signal-to-noise ratio SNRN ratio of signal-to-noise, normalized by the basic spatial resolution, SRbimage, (3.5) as measured directly in the digital image and/or calculated from the measured SNRmeasured, by:
Contents of GB/T 43658.1-2024
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB/T 43658.1-2024, GB 43658.1-2024, GBT 43658.1-2024, GB/T43658.1-2024, GB/T 43658.1, GB/T43658.1, GB43658.1-2024, GB 43658.1, GB43658.1, GBT43658.1-2024, GBT 43658.1, GBT43658.1