2025-12-5 10.1.6.65
Code of China Chinese Classification Professional Classification ICS Classification Latest News Value-added Services

Position: Chinese Standard in English/GB 5009.278-2016
GB 5009.278-2016   National Food Safety Standard - Determination of Tetraacetate in Food (English Version)
Standard No.: GB 5009.278-2016 Status:valid remind me the status change

Email:

Target Language:English File Format:PDF
Word Count: 4000 words Translation Price(USD):110.0 remind me the price change

Email:

Implemented on:2017-6-23 Delivery: via email in 1 business day

→ → →

,,2017-6-23,E41E991D1DF025091484575744192
Standard No.: GB 5009.278-2016
English Name: National Food Safety Standard - Determination of Tetraacetate in Food
Chinese Name: 食品安全国家标准 食品中乙二胺四乙酸盐的测定
Professional Classification: GB    National Standard
Source Content Issued by: National Health and Family Planning Commission; China Food and Drug Administration
Issued on: 2016-12-23
Implemented on: 2017-6-23
Status: valid
Superseding:SN/T 1018-2001 Method for the determination of ethylenediaminetetraacetic acid content in canned food for export
Target Language: English
File Format: PDF
Word Count: 4000 words
Translation Price(USD): 110.0
Delivery: via email in 1 business day
1 Scope This standard specifies the method for determination of ethylenediaminetetraacetateedetate in food through liquid chromatograph. This standard is applicable to the determination of ethylene diamine tetraacetic acid disodium in jam, preserved fruit, canned pickled vegetables, vegetable puree (sauce) except tomato sauce, canned nuts and seeds, canned mixed congee, compound seasonings and beverages and the determination of ethylene diamine tetraacetic acid disodium calcium in compound seasonings. This standard does not apply to the determination of ethylenediaminetetraacetic acid ferric sodium in iron fortified soy sauce. 2 Principle Extract the specimen of to be determined ethylenediamine tetraacetic acid disodium by water. Add ferric chloride into the extracting solution for complexing. Purify the solution by mixed anion (PXA) solid phase extraction column, detect by liquid chromatograph, and quantify by external standard method. When determining compound seasoning, determine the total content of ferric chloride complex of ethylenediaminetetraacetateedetate firstly, and then the content of ethylenediamine tetraacetic acid disodium calcium. Identify the content of ethylenediamine tetraacetic acid disodium according to the results. 3 Reagents and materials Unless otherwise stated, reagents used in this method are analytical reagents, and the water is Class-I water as specified in GB/T 6682. 3.1 Reagents 3.1.1 Methanol (CH3OH): chromatographically pure. 3.1.2 Hydrochloric acid (HCl). 3.1.3 Phosphoric acid (H3PO4) 3.1.4 Methanoic acid (CH2O2): chromatographically pure. 3.1.5 Tetrabutylammonium bromide (C16H36NBr). 3.1.6 Sodium acetate (CH3COONa). 3.1.7 Ferric chloride (FeCl3·6H2O). 3.2 Preparation of reagents 3.2.1 Ferric chloride solution: weigh 0.54 g of ferric chloride, dissolve it in 90 mL of water, add 0.10 mL of hydrochloric acid, transfer it to a 100-mL volumetric flask, dilute to scale with water, and mix it well. 3.2.2 5 % methanoic acid methanol aqueous solution: take 5 mL of methanoic acid and 20 mL of methanol and dilute to 100 mL with water. 3.2.3 Tetrabutylammonium bromide-sodium acetate mixed solution (pH 4.0): weigh 6.45 g of tetrabutylammonium bromide and 2.46 g of sodium acetate, add 1,000 mL of water for ultrasonic dissolution, and add phosphoric acid to adjust pH to 4.0±0.1. 3.2.4 Tetrabutylammonium bromide-sodium acetate mixed solution (pH 2.5): weigh 6.45g of tetrabutylammonium bromide and 2.46g of sodium acetate, add 1,000mL of water for ultrasonic dissolution, and add phosphoric acid to adjust pH to 2.5±0.1. 3.3 Standard 3.3.1 Ethylenediamine tetraacetic acid disodium standard (C10H14N2O8Na2•2H2O, CAS No.: 6381-92-6): purity ≥ 99 % 3.3.2 Ethylenediamine tetraacetic acid disodium (C10H14N2O8Na2Ca, CAS No.: 62-33-9): purity ≥ 99 %. 3.4 Preparation of standard solution 3.4.1 Ethylenediamine tetraacetic acid disodium standard solution: accurately weigh an appropriate amount of ethylenediamine tetraacetic acid disodium standard, dissolve it and dilute the solution in a 100-mL brown volumetric flask with water, so as to obtain a 10 mg/mL standard stock solution. Transfer the solution to liquid storage flask and store it at 4 ℃. 3.4.2 Ethylenediamine tetraacetic acid disodium standard series solution: pipet 1volume of ethylenediamine tetraacetic acid disodium standard solution and dilute it with 9 volumes of water into 1 mg/mL standard intermediate solution. Then dilute the standard intermediate solution with water to series standard working solutions with the concentrations of 0.5 μg/mL, 2.0 μg/mL, 5.0 μg/mL, 10.0 μg/mL and 50.0 μg/mL. 3.4.3 Ethylenediamine tetraacetic acid disodium calcium standard solution: accurately weigh an appropriate amount of ethylenediamine tetraacetic acid disodium calcium standard, dissolve it and dilute the solution in a 100-mL brown volumetric flask with water, so as to obtain 10 mg/mL standard stock solutions. Transfer the solution to liquid storage flask and store it at 4 ℃. 3.4.4 Ethylenediamine tetraacetic acid disodium calcium standard series solution: pipet 1volume of ethylenediamine tetraacetic acid disodium calcium standard solution and dilute it with 9 volumes of water into 1 mg/mL standard intermediate solution. Then dilute the ethylenediamine tetraacetic acid disodium calcium standard intermediate solution with water to series standard working solutions with the concentrations of 1.0 μg/mL, 10.0 μg/mL, 20.0 μg/mL, 50.0 μg/mL and 100.0 μg/mL. 4 Apparatus 4.1 Liquid chromatograph: equipped with ultraviolet detector. 4.2 Electronic balance: with a sensitivity of 0.1 mg and 0.01 g. 4.3 Centrifuge: rotating speed ≥ 7,500 r/min. 4.4 Vortex oscillator. 4.5 Ultrasonic cleaning machine. 4.6 pH meter: with an accuracy of 0.01. 4.7 24-hole solid phase extraction unit. 4.8 Millipore filter membrane: 0.45 μm. 4.9 Mixed anion (PXA) solid phase extraction column: 150 mg/6 mL or the equivalent. The main ingredient of PXA is quaternary group bonded to polystyrene/divinylbenzene copolymer with hydrophilic group. 5 Analysis procedures 5.1 Specimen preparation   5.1.1 Solid sample Smash the sample by crusher, mix well. Then pack it in a clean container, seal and mark well. Samples with high sugar content need to be smashed after freezing. The specimen shall be preserved at 4 ℃. 5.1.2 Liquid sample Samples with fruit particles need to be smashed by juicer and mixed well. Then pack it in a clean container, seal and mark well. Take 500 mL of carbonated beverage into a 1,000-mL beaker, heat it while stirring in a 70 ℃ water bath to remove part of carbon dioxide, after cooling to room temperature, pack it in a clean container, seal and mark well. The specimen shall be preserved at 4 ℃. 5.2 Determination 5.2.1 Determination of the total content of ethylenediaminetetraacetateedetate 5.2.1.1 Extraction 5.2.1.1.1 Samples immiscible with water Weigh 5g of specimen (accurate to 0.01 g), put it in a 50-mL centrifuge tube, add 25 mL of water, mix well by subjecting it to vortex, subject it to ultrasound for 20 min, centrifuge it at 7,500 r/min for 5 min, and take the supernatant in a 50-mL glass colorimetric tube. Extract the remaining residue once again, and after centrifugation, combine the supernatants, and dilute to 50 mL with water. Pipet 5 mL of the diluted solution into a 15-mL centrifuge tube for complexation. 5.2.1.1.2 Samples miscible with water Weigh 5 g of specimen (accurate to 0.01 g), put it in a 50-mL glass colorimetric tube, add 25 mL of water, mix well by subjecting it to vortex, after ultrasonic extraction for 20min, dilute the solution to 50 mL with water. Pipet 5 mL of supernatant into a 15-mL centrifuge tube for complexation. 5.2.1.2 Complexation Add 0.5 mL of ferric chloride solution to the above extracted solution, mix for 1 min by subjecting it to vortex, subject it to ultrasound for 20 min, and centrifuge it for 5 min at 7,500 r/min for purification.
Foreword i 1 Scope 2 Principle 3 Reagents and materials 4 Apparatus 5 Analysis procedures 6 Expression of analysis results 7 Precision 8 Others Annex A Liquid chromatograms of ethylenediamine tetraacetic acid disodium complex standard solution and ethylenediamine tetraacetic acid disodium calcium standard solution
Referred in GB 5009.278-2016:
*GB 17930-2016 Gasoline for motor vehicles
*GB 5413.30-2016 National Food Safety Standard Determination of Impurities in Milk and Milk Products
*GB 5009.268-2016 National Food Safety Standard--Determination of Multi-elements in Foods
*JT/T 719-2016 Limits and measurement methods of fuel consumption for commercial vehicle for cargos transportation
*JT/T 711-2016 Limits and measurement methods of fuel consumption for commercial vehicle for passenger transportation
*JT/T 327-2016 Technical Specification on Highway Bridge Expansion and Contraction Installation
*JGJ 36-2016 Code for design of dormitory building
*GB/T 33271-2016 Woven garments for infants
*GB/T 22700-2016 Washed garments
*GB/T 18132-2016 Silk Garments
*WS 310.1-2016 Central sterile supply department(CSSD) Part 1:Management standard
*GB/T 33460-2016 Specifications for compiling dismantling manual of end-of-life vehicles
*WS 507-2016 Regulation for cleaning and disinfection technique of flexible endoscope
*GB/T 19000-2016 Quality management systems―Fundamentals and vocabulary
*GB/T 33282-2016 General technical requirements for indoor stone furniture
GB 5009.278-2016 is referred in:
*GB 5009.267-2016 National Food Safety Standard Determination of Iodine in Foods
*GB 4789.6-2016 National food safety standard -Microbiological examination of food-Examination of diarrheogenic Escherichia coli
*GB 4789.2-2016 National food safety standard -Microbiological examination of food: Aerobic plate count
*GB 4789.1-2016 National Food Safety Standard—Food Microbiological Examination—General
*GB 4789.12-2016 National Food Safety Standard—Food Microbiological Examination—Clostridium Botulinum and Botulinum Toxin
*GB 4789.10-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Staphylococcus Aureus
*GB 4789.35-2016 National food safety standard -Microbiological examination of food-Examination of lactic acid bacteria
*GB 4789.36-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Escherichia Coli O157:H7/MN
*GB 4789.30-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Listeria Monocytogenes
*GB 4789.40-2016 National Food Safety Standard—Food Microbiological Examination—Examination of Cronobacter (Enterobacter Sakazakii)
*GB 4789.43-2016 National Food Safety Standard - Food Microbiological Examination -Determination of Antibacterial Activity of Microbe-source Enzyme
*GB 5009.271-2016 National Food Safety Standard - Determination of Phthalates in Food
*GB 5009.270-2016 National Food Safety Standard--Determination of Inositol in Foods
*GB/T 28869.1-2012 Cores made of soft magnetic materials - Measuring methods - Part 1:Generic specification
*GB/T 4324.1-2012 Methods for chemical analysis of tungsten - Part 1: Determination of lead content - Flame atomic absorption spectrometry
*GB/T 4324.9-2012 Methods for chemical analysis of tungsten - Part 9: Determination of cadmium content - Inductively coupled plasma atomic emission spectrometry and flame atomic absorption spectrometry
*GB 18613-2012 Minimum allowable values of energy efficiency and energy efficiency grades for small and medium three-phase asynchronous motors
*GB/T 18851.1-2012 Non-destructive testing—Penetrant testing—Part 1:General principles
*GB/T 28697-2012 Rolling bearings—Aligning thrust ball bearings and aligning seat washers—Boundary dimensions
*GB/T 5800.1-2012 Rolling bearings—Instrument precision bearings—Part 1:Boundary dimensions,tolerances and characteristics of metric series bearings
*YB/T 2012-2004 Continuous casting slab
*HJ 636-2012 Water quality. Determination of total nitrogen. Alkaline potassium persulfate digestion UV spectrophotometric method
*JB/T 11288-2012 Coated abrasives — Flap wheels with incorporated flanges or separate flanges — Technical specifications
*SB/T 10131-2012 Technical specifications for stamping hard candy forming machine
*JJF 1355-2012 Program of Pattern Evaluation for Non-automatic Weighing Instruments (Analogue Indicating Weighing Instruments)
*JJG 388-2012 Audiological Equiqment; Pure-tone Audiometers
*JJF 1369-2012 Program of Pattern Evaluation of Compressed Natural Gas Dispensers
*GB 18133-2012 Seed potatoes
*GB/T 17780.1-2012 Textile machinery - Safety requirements - Part 1: Common requirements
*GB/T 17780.2-2012 Textile machinery - Safety requirements - Part 2: Spinning preparatory and spinning machines
*GB/T 17780.5-2012 Textile machinery - Safety requirements - Part 5: Preparatory machinery to weaving and knitting
*GB/T 17780.6-2012 Textile machinery - Safety requirements - Part 6: Fabric manufacturing machinery
*GB/T 17780.7-2012 Textile machinery - Safety requirements - Part 7: Dyeing and finishing machinery
*TB/T 2328.19-2008 Test Method for Railway Ballast - Part 19: Standard for the Ballast Mesh Sieve
*SN/T 2230-2008 Determination of procymidone residues in food for import and export - GC-MS method
*GB 19643-2005/XG1-2008 Hygienic standard for marine algae and algae products, includes Amendment 1
*DG/TJ 08-79-2008 Housing quality inspection specification
*GB/T 14048.3-2008 Low-voltage switchgear and controlgear - Part 3:Switches disconnectors switch-disconnectors and fuse-combination units
*DB37/T 1104-2008 Determination of Saccharine Sodium in Foods - Liquid Chromatography - Mass Spectrometry
*GB/T 20014.3-2008 GB/T 2001 4.3-2008 Good agricultural practice - Part 3: Crops base control points and compliance criteria
*GB/T 20014.9-2008 GB/T 2001 4.9-2008 Good agricultural practice - Part 9: Pig control points and compliance criteria
*GB/T 20014.5-2008 GB/T 2001 4.5-2008 Good agricultural practice - Part 5: Fruit and vegetable control points and compliance criteria
*SL 144.1~11-2008 Calibration methods of water environmental detecting insturment and and equipment
*DB53/T 249-2008 Technical Regulation for Forest Seedling Cultivation
*GB/T 12977-2008 Balancing machines - Enclosures and other protective measures for the measuring station
*GB/T 13960.2-2008 Safety of transportable motor operated electric tools - Part 2: Particular requirements for circular saws
*GB/T 10963.2-2008 Circuit-breakers for overcurrent protection for household and similar installation―Part 2:Circuit-breakers for a.c.and d.c.operation
*GB/T 19104-2008 Peracetic acid solution
*GB/T 17701-2008 Circuit-breaker for equipment
*GB/T 15766.1-2008 Lamps for road vehicles -- Dimensional, electrical and luminous requirements
*GB/T 20041.21-2008 Conduit systems for cable management―Part 21:Particular requirement―Rigid conduit systems
Code of China
Standard
GB 5009.278-2016  National Food Safety Standard - Determination of Tetraacetate in Food (English Version)
Standard No.GB 5009.278-2016
Statusvalid
LanguageEnglish
File FormatPDF
Word Count4000 words
Price(USD)110.0
Implemented on2017-6-23
Deliveryvia email in 1 business day
Detail of GB 5009.278-2016
Standard No.
GB 5009.278-2016
English Name
National Food Safety Standard - Determination of Tetraacetate in Food
Chinese Name
食品安全国家标准 食品中乙二胺四乙酸盐的测定
Chinese Classification
Professional Classification
GB
ICS Classification
Issued by
National Health and Family Planning Commission; China Food and Drug Administration
Issued on
2016-12-23
Implemented on
2017-6-23
Status
valid
Superseded by
Superseded on
Abolished on
Superseding
SN/T 1018-2001 Method for the determination of ethylenediaminetetraacetic acid content in canned food for export
Language
English
File Format
PDF
Word Count
4000 words
Price(USD)
110.0
Keywords
GB 5009.278-2016, GB/T 5009.278-2016, GBT 5009.278-2016, GB5009.278-2016, GB 5009.278, GB5009.278, GB/T5009.278-2016, GB/T 5009.278, GB/T5009.278, GBT5009.278-2016, GBT 5009.278, GBT5009.278
Introduction of GB 5009.278-2016
1 Scope This standard specifies the method for determination of ethylenediaminetetraacetateedetate in food through liquid chromatograph. This standard is applicable to the determination of ethylene diamine tetraacetic acid disodium in jam, preserved fruit, canned pickled vegetables, vegetable puree (sauce) except tomato sauce, canned nuts and seeds, canned mixed congee, compound seasonings and beverages and the determination of ethylene diamine tetraacetic acid disodium calcium in compound seasonings. This standard does not apply to the determination of ethylenediaminetetraacetic acid ferric sodium in iron fortified soy sauce. 2 Principle Extract the specimen of to be determined ethylenediamine tetraacetic acid disodium by water. Add ferric chloride into the extracting solution for complexing. Purify the solution by mixed anion (PXA) solid phase extraction column, detect by liquid chromatograph, and quantify by external standard method. When determining compound seasoning, determine the total content of ferric chloride complex of ethylenediaminetetraacetateedetate firstly, and then the content of ethylenediamine tetraacetic acid disodium calcium. Identify the content of ethylenediamine tetraacetic acid disodium according to the results. 3 Reagents and materials Unless otherwise stated, reagents used in this method are analytical reagents, and the water is Class-I water as specified in GB/T 6682. 3.1 Reagents 3.1.1 Methanol (CH3OH): chromatographically pure. 3.1.2 Hydrochloric acid (HCl). 3.1.3 Phosphoric acid (H3PO4) 3.1.4 Methanoic acid (CH2O2): chromatographically pure. 3.1.5 Tetrabutylammonium bromide (C16H36NBr). 3.1.6 Sodium acetate (CH3COONa). 3.1.7 Ferric chloride (FeCl3·6H2O). 3.2 Preparation of reagents 3.2.1 Ferric chloride solution: weigh 0.54 g of ferric chloride, dissolve it in 90 mL of water, add 0.10 mL of hydrochloric acid, transfer it to a 100-mL volumetric flask, dilute to scale with water, and mix it well. 3.2.2 5 % methanoic acid methanol aqueous solution: take 5 mL of methanoic acid and 20 mL of methanol and dilute to 100 mL with water. 3.2.3 Tetrabutylammonium bromide-sodium acetate mixed solution (pH 4.0): weigh 6.45 g of tetrabutylammonium bromide and 2.46 g of sodium acetate, add 1,000 mL of water for ultrasonic dissolution, and add phosphoric acid to adjust pH to 4.0±0.1. 3.2.4 Tetrabutylammonium bromide-sodium acetate mixed solution (pH 2.5): weigh 6.45g of tetrabutylammonium bromide and 2.46g of sodium acetate, add 1,000mL of water for ultrasonic dissolution, and add phosphoric acid to adjust pH to 2.5±0.1. 3.3 Standard 3.3.1 Ethylenediamine tetraacetic acid disodium standard (C10H14N2O8Na2•2H2O, CAS No.: 6381-92-6): purity ≥ 99 % 3.3.2 Ethylenediamine tetraacetic acid disodium (C10H14N2O8Na2Ca, CAS No.: 62-33-9): purity ≥ 99 %. 3.4 Preparation of standard solution 3.4.1 Ethylenediamine tetraacetic acid disodium standard solution: accurately weigh an appropriate amount of ethylenediamine tetraacetic acid disodium standard, dissolve it and dilute the solution in a 100-mL brown volumetric flask with water, so as to obtain a 10 mg/mL standard stock solution. Transfer the solution to liquid storage flask and store it at 4 ℃. 3.4.2 Ethylenediamine tetraacetic acid disodium standard series solution: pipet 1volume of ethylenediamine tetraacetic acid disodium standard solution and dilute it with 9 volumes of water into 1 mg/mL standard intermediate solution. Then dilute the standard intermediate solution with water to series standard working solutions with the concentrations of 0.5 μg/mL, 2.0 μg/mL, 5.0 μg/mL, 10.0 μg/mL and 50.0 μg/mL. 3.4.3 Ethylenediamine tetraacetic acid disodium calcium standard solution: accurately weigh an appropriate amount of ethylenediamine tetraacetic acid disodium calcium standard, dissolve it and dilute the solution in a 100-mL brown volumetric flask with water, so as to obtain 10 mg/mL standard stock solutions. Transfer the solution to liquid storage flask and store it at 4 ℃. 3.4.4 Ethylenediamine tetraacetic acid disodium calcium standard series solution: pipet 1volume of ethylenediamine tetraacetic acid disodium calcium standard solution and dilute it with 9 volumes of water into 1 mg/mL standard intermediate solution. Then dilute the ethylenediamine tetraacetic acid disodium calcium standard intermediate solution with water to series standard working solutions with the concentrations of 1.0 μg/mL, 10.0 μg/mL, 20.0 μg/mL, 50.0 μg/mL and 100.0 μg/mL. 4 Apparatus 4.1 Liquid chromatograph: equipped with ultraviolet detector. 4.2 Electronic balance: with a sensitivity of 0.1 mg and 0.01 g. 4.3 Centrifuge: rotating speed ≥ 7,500 r/min. 4.4 Vortex oscillator. 4.5 Ultrasonic cleaning machine. 4.6 pH meter: with an accuracy of 0.01. 4.7 24-hole solid phase extraction unit. 4.8 Millipore filter membrane: 0.45 μm. 4.9 Mixed anion (PXA) solid phase extraction column: 150 mg/6 mL or the equivalent. The main ingredient of PXA is quaternary group bonded to polystyrene/divinylbenzene copolymer with hydrophilic group. 5 Analysis procedures 5.1 Specimen preparation   5.1.1 Solid sample Smash the sample by crusher, mix well. Then pack it in a clean container, seal and mark well. Samples with high sugar content need to be smashed after freezing. The specimen shall be preserved at 4 ℃. 5.1.2 Liquid sample Samples with fruit particles need to be smashed by juicer and mixed well. Then pack it in a clean container, seal and mark well. Take 500 mL of carbonated beverage into a 1,000-mL beaker, heat it while stirring in a 70 ℃ water bath to remove part of carbon dioxide, after cooling to room temperature, pack it in a clean container, seal and mark well. The specimen shall be preserved at 4 ℃. 5.2 Determination 5.2.1 Determination of the total content of ethylenediaminetetraacetateedetate 5.2.1.1 Extraction 5.2.1.1.1 Samples immiscible with water Weigh 5g of specimen (accurate to 0.01 g), put it in a 50-mL centrifuge tube, add 25 mL of water, mix well by subjecting it to vortex, subject it to ultrasound for 20 min, centrifuge it at 7,500 r/min for 5 min, and take the supernatant in a 50-mL glass colorimetric tube. Extract the remaining residue once again, and after centrifugation, combine the supernatants, and dilute to 50 mL with water. Pipet 5 mL of the diluted solution into a 15-mL centrifuge tube for complexation. 5.2.1.1.2 Samples miscible with water Weigh 5 g of specimen (accurate to 0.01 g), put it in a 50-mL glass colorimetric tube, add 25 mL of water, mix well by subjecting it to vortex, after ultrasonic extraction for 20min, dilute the solution to 50 mL with water. Pipet 5 mL of supernatant into a 15-mL centrifuge tube for complexation. 5.2.1.2 Complexation Add 0.5 mL of ferric chloride solution to the above extracted solution, mix for 1 min by subjecting it to vortex, subject it to ultrasound for 20 min, and centrifuge it for 5 min at 7,500 r/min for purification.
Contents of GB 5009.278-2016
Foreword i 1 Scope 2 Principle 3 Reagents and materials 4 Apparatus 5 Analysis procedures 6 Expression of analysis results 7 Precision 8 Others Annex A Liquid chromatograms of ethylenediamine tetraacetic acid disodium complex standard solution and ethylenediamine tetraacetic acid disodium calcium standard solution
About Us   |    Contact Us   |    Terms of Service   |    Privacy   |    Cancellation & Refund Policy   |    Payment
Tel: +86-10-8572 5655 | Fax: +86-10-8581 9515 | Email: coc@codeofchina.com | QQ: 672269886
Copyright: Beijing COC Tech Co., Ltd. 2008-2040
 
 
Keywords:
GB 5009.278-2016, GB/T 5009.278-2016, GBT 5009.278-2016, GB5009.278-2016, GB 5009.278, GB5009.278, GB/T5009.278-2016, GB/T 5009.278, GB/T5009.278, GBT5009.278-2016, GBT 5009.278, GBT5009.278